All Categories

History

On-site conductive rate meter FEB-102-Ech (high concentration)-FEB-102-Ech, C5
On-site conductive rate meter FEB-102-Ech (high concentration)-Shinko Technos Co., Ltd.

On-site conductive rate meter FEB-102-Ech (high concentration)
Shinko Technos Co., Ltd.

💊 Pharmaceutical & Medical Use ♻️ Environment & Recycling Use 🧪 Chemical Industry Use

Shinko Technos Co., Ltd.'s Response Status

Response Rate

100.0%

Response Time

56.0hours


About This Product

This type of on -site conductor is installed on walls that support various purposes such as hydroponic cultivation, cooling tower (cooling tower), water maintenance, salt measurement, and environmental measurement. ・ Equipped with 2 points in contact with contact (EVT output) and 2 points (transmission output) ・ Communication (RS-485) (optional) ・ Dustproof / drip -proof structure IP65: Compatible with outdoor use

  • Product

    On-site conductive rate meter FEB-102-Ech (high concentration)
  • Usage Scenarios

    Pharmaceutical & Medical Use / Environment & Recycling Use / Chemical Industry Use

Share this product


250+ people viewing

Last viewed: 3 hours ago


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

3 Models of On-site conductive rate meter FEB-102-Ech (high concentration)

Click on the part number for more information about each product

Image Part Number Price (excluding tax) input Repetition Linearness Temperature instruction accuracy Input sampling cycle Time accuracy EVT output (2 points) 1 EVT output (2 points) 2 EVT output (2 points) 3 Calibration function Transmission output 1, 2-1 Transmission output 1, 2-2 Self -diagnostic function Ambient temperature Peripheral humidity power supply power consumption Mounting method Case, panel Drip -proof / dustproof structure Conformity standard External dimensions mass Serial communication (Options: C5) Serial communication (option: C5) cable length Serial communication (option: C5) communication line Serial communication (Options: C5) Communication method Serial communication (option: C5) communication speed Serial communication (option: C5) synchronous method Serial communication (option: C5) Certification format
On-site conductive rate meter FEB-102-Ech (high concentration)-Part Number-FEB-102-Ech, C5

FEB-102-Ech, C5

Available upon quote

4 -pole conductive rate sensor (temperature element PT100 or PT1000)

・ Conductive: ± 0.5%of measuring range span ・ Salt conversion: Measurement range span ± 1%・ TDS conversion: measuring range span ± 1.5%

・ Conductive: ± 0.5%of measuring range span ・ Salt conversion: Measurement range span ± 1%・ TDS conversion: measuring range span ± 1.5%

± 1 ℃

250 MS (2 input)

Within ± 1%for the set time

・ Setting accuracy: Same as instruction accuracy
・ Output operation: P operation proportional belt other than 0, when the ON/OFF operation proportional belt is set to 0.
・ Relay contact 1A

・ Control capacity: 3A 250V AC (resistance load), 1A 250V AC (induced load COSφ = 0.4)
・ Electrical life: 100,000 times

・ Operation ON delay timer: 0 to 10000 seconds
・ Operation OFF delay timer: 0 to 10000 seconds

・ Conductive proofreading: Calonization of zero conductive rate and conductive rate span adjustment.
・ Temperature school regular (1 point)

Conductive, temperature, and MV are converted to analog amount for each input sampling and output by current. (The decimal position is fixed regardless of the decimal position selection)

・ Dusive ability: 12000 ・ Current: 4 ~ 20mA DC (maximum load resistance 550Ω) ・ Output accuracy: within ± 0.3%of transmission output span

Motor the CPU with a watchdog timer and make the instrument into an initial state in the event of an abnormality.

-20 ~ 50 ° C (how to adapt to the instruction accuracy at 0 to 50 ° C and avoid direct sunlight)

35 ~ 95%RH (but not condensation)

100 ~ 240 V AC 50/60 Hz tolerance fluctuation range: 85 ~ 264 v AC

Approximately 10 VA

Wall installation method

・ Case: Polycarbonate color: Metallic gray
・ Panel: Membrane sheet

IP65

ROHS command support

W239.5xh190XD75mm

Approximately 950g

Perform the following operations from the external computer.
・ Read and set various set values
・ Conductive, salt conversion, temperature or state reading
・ Change and adjust function

1.2 km (maximum) Cable resistance within 50Ω (end resistance: None or 120Ω or more on both sides)

EIA RS-485 compliant

Half double communication

Select 9600, 19200, 38400 BPS by key operation

Toning synchronization

ASCII, binary

On-site conductive rate meter FEB-102-Ech (high concentration)-Part Number-FEB-102-Ech, EVT3

FEB-102-Ech, EVT3

Available upon quote

4 -pole conductive rate sensor (temperature element PT100 or PT1000)

・ Conductive: ± 0.5% of measurement range span
・ Salt conversion: ± 1% of measured range span
・ TDS conversion: ± 1.5% of measurement range span

・ Conductive: ± 0.5% of measurement range span
・ Salt conversion: ± 1% of measured range span
・ TDS conversion: ± 1.5% of measurement range span

± 1 ℃

250 MS (2 input)

Within ± 1%for the set time

・ Setting accuracy: Same as instruction accuracy
・ Output operation: P operation proportional belt other than 0, when the ON/OFF operation proportional belt is set to 0.
・ Relay contact 1A

・ Control capacity: 3A 250V AC (resistance load), 1A 250V AC (induced load COSφ = 0.4)
・ Electrical life: 100,000 times

・ Operation ON delay timer: 0 to 10000 seconds
・ Operation OFF delay timer: 0 to 10000 seconds

・ Conductive proofreading: Calonization of zero conductive rate and conductive rate span adjustment.
・ Temperature school regular (1 point)

Conductive, temperature, and MV are converted to analog amount for each input sampling and output by current. (The decimal position is fixed regardless of the decimal position selection)

・ Dusive ability: 12000 ・ Current: 4 ~ 20mA DC (maximum load resistance 550Ω) ・ Output accuracy: within ± 0.3%of transmission output span

Motor the CPU with a watchdog timer and make the instrument into an initial state in the event of an abnormality.

-20 ~ 50 ° C (how to adapt to the instruction accuracy at 0 to 50 ° C and avoid direct sunlight)

35 ~ 95%RH (but not condensation)

100 ~ 240 V AC 50/60 Hz tolerance fluctuation range: 85 ~ 264 v AC

Approximately 10 VA

Wall installation method

・ Case: Polycarbonate color: Metallic gray
・ Panel: Membrane sheet

IP65

ROHS command support

W239.5xh190XD75mm

Approximately 950g

Perform the following operations from the external computer.
・ Read and set various set values
・ Conductive, salt conversion, temperature or state reading
・ Change and adjust function

1.2 km (maximum) Cable resistance within 50Ω (end resistance: None or 120Ω or more on both sides)

EIA RS-485 compliant

Half double communication

Select 9600, 19200, 38400 BPS by key operation

Toning synchronization

ASCII, binary

On-site conductive rate meter FEB-102-Ech (high concentration)-Part Number-FEB-102-Ech, EVT4

FEB-102-Ech, EVT4

Available upon quote

4 -pole conductive rate sensor (temperature element PT100 or PT1000)

・ Conductive: ± 0.5% of measurement range span
・ Salt conversion: ± 1% of measured range span
・ TDS conversion: ± 1.5% of measurement range span

・ Conductive: ± 0.5% of measurement range span
・ Salt conversion: ± 1% of measured range span
・ TDS conversion: ± 1.5% of measurement range span

± 1 ℃

250 MS (2 input)

Within ± 1%for the set time

・ Setting accuracy: Same as instruction accuracy
・ Output operation: P operation proportional belt other than 0, when the ON/OFF operation proportional belt is set to 0.
・ Relay contact 1A

・ Control capacity: 3A 250V AC (resistance load), 1A 250V AC (induced load COSφ = 0.4)
・ Electrical life: 100,000 times

・ Operation ON delay timer: 0 to 10000 seconds
・ Operation OFF delay timer: 0 to 10000 seconds

・ Conductive proofreading: Calonization of zero conductive rate and conductive rate span adjustment.
・ Temperature school regular (1 point)

Conductive, temperature, and MV are converted to analog amount for each input sampling and output by current. (The decimal position is fixed regardless of the decimal position selection)

・ Dusive ability: 12000 ・ Current: 4 ~ 20mA DC (maximum load resistance 550Ω) ・ Output accuracy: within ± 0.3%of transmission output span

Motor the CPU with a watchdog timer and make the instrument into an initial state in the event of an abnormality.

-20 ~ 50 ° C (how to adapt to the instruction accuracy at 0 to 50 ° C and avoid direct sunlight)

35 ~ 95%RH (but not condensation)

100 ~ 240 V AC 50/60 Hz tolerance fluctuation range: 85 ~ 264 v AC

Approximately 10 VA

Wall installation method

・ Case: Polycarbonate color: Metallic gray
・ Panel: Membrane sheet

IP65

ROHS command support

W239.5xh190XD75mm

Approximately 950g

Perform the following operations from the external computer.
・ Read and set various set values
・ Conductive, salt conversion, temperature or state reading
・ Change and adjust function

1.2 km (maximum) Cable resistance within 50Ω (end resistance: None or 120Ω or more on both sides)

EIA RS-485 compliant

Half double communication

Select 9600, 19200, 38400 BPS by key operation

Toning synchronization

ASCII, binary

Click on the part number for more information about each product

Customers who viewed this product also viewed

Reviews shown here are reviews of companies.

See More Conductivity Meters Products

Other products of Shinko Technos Co., Ltd.

Reviews shown here are reviews of companies.


View more products of Shinko Technos Co., Ltd.

About Company Handling This Product

Response Rate

100.0%


Response Time

56.0hrs

  • Japan

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.