On-site conductive rate meter FEB-102-Ech (high concentration)Handling Company
Shinko Technos Co., Ltd.Categories
Usage Scenarios
Pharmaceutical & Medical Use / Environment & Recycling Use / Chemical Industry UseClick on the part number for more information about each product
Image | Part Number | Price (excluding tax) | input | Repetition | Linearness | Temperature instruction accuracy | Input sampling cycle | Time accuracy | EVT output (2 points) 1 | EVT output (2 points) 2 | EVT output (2 points) 3 | Calibration function | Transmission output 1, 2-1 | Transmission output 1, 2-2 | Self -diagnostic function | Ambient temperature | Peripheral humidity | power supply | power consumption | Mounting method | Case, panel | Drip -proof / dustproof structure | Conformity standard | External dimensions | mass | Serial communication (Options: C5) | Serial communication (option: C5) cable length | Serial communication (option: C5) communication line | Serial communication (Options: C5) Communication method | Serial communication (option: C5) communication speed | Serial communication (option: C5) synchronous method | Serial communication (option: C5) Certification format |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
FEB-102-Ech, C5 |
Available upon quote |
4 -pole conductive rate sensor (temperature element PT100 or PT1000) |
・ Conductive: ± 0.5%of measuring range span ・ Salt conversion: Measurement range span ± 1%・ TDS conversion: measuring range span ± 1.5% |
・ Conductive: ± 0.5%of measuring range span ・ Salt conversion: Measurement range span ± 1%・ TDS conversion: measuring range span ± 1.5% |
± 1 ℃ |
250 MS (2 input) |
Within ± 1%for the set time |
・ Setting accuracy: Same as instruction accuracy |
・ Control capacity: 3A 250V AC (resistance load), 1A 250V AC (induced load COSφ = 0.4) |
・ Operation ON delay timer: 0 to 10000 seconds |
・ Conductive proofreading: Calonization of zero conductive rate and conductive rate span adjustment. |
Conductive, temperature, and MV are converted to analog amount for each input sampling and output by current. (The decimal position is fixed regardless of the decimal position selection) |
・ Dusive ability: 12000 ・ Current: 4 ~ 20mA DC (maximum load resistance 550Ω) ・ Output accuracy: within ± 0.3%of transmission output span |
Motor the CPU with a watchdog timer and make the instrument into an initial state in the event of an abnormality. |
-20 ~ 50 ° C (how to adapt to the instruction accuracy at 0 to 50 ° C and avoid direct sunlight) |
35 ~ 95%RH (but not condensation) |
100 ~ 240 V AC 50/60 Hz tolerance fluctuation range: 85 ~ 264 v AC |
Approximately 10 VA |
Wall installation method |
・ Case: Polycarbonate color: Metallic gray |
IP65 |
ROHS command support |
W239.5xh190XD75mm |
Approximately 950g |
Perform the following operations from the external computer. |
1.2 km (maximum) Cable resistance within 50Ω (end resistance: None or 120Ω or more on both sides) |
EIA RS-485 compliant |
Half double communication |
Select 9600, 19200, 38400 BPS by key operation |
Toning synchronization |
ASCII, binary |
|
FEB-102-Ech, EVT3 |
Available upon quote |
4 -pole conductive rate sensor (temperature element PT100 or PT1000) |
・ Conductive: ± 0.5% of measurement range span |
・ Conductive: ± 0.5% of measurement range span |
± 1 ℃ |
250 MS (2 input) |
Within ± 1%for the set time |
・ Setting accuracy: Same as instruction accuracy |
・ Control capacity: 3A 250V AC (resistance load), 1A 250V AC (induced load COSφ = 0.4) |
・ Operation ON delay timer: 0 to 10000 seconds |
・ Conductive proofreading: Calonization of zero conductive rate and conductive rate span adjustment. |
Conductive, temperature, and MV are converted to analog amount for each input sampling and output by current. (The decimal position is fixed regardless of the decimal position selection) |
・ Dusive ability: 12000 ・ Current: 4 ~ 20mA DC (maximum load resistance 550Ω) ・ Output accuracy: within ± 0.3%of transmission output span |
Motor the CPU with a watchdog timer and make the instrument into an initial state in the event of an abnormality. |
-20 ~ 50 ° C (how to adapt to the instruction accuracy at 0 to 50 ° C and avoid direct sunlight) |
35 ~ 95%RH (but not condensation) |
100 ~ 240 V AC 50/60 Hz tolerance fluctuation range: 85 ~ 264 v AC |
Approximately 10 VA |
Wall installation method |
・ Case: Polycarbonate color: Metallic gray |
IP65 |
ROHS command support |
W239.5xh190XD75mm |
Approximately 950g |
Perform the following operations from the external computer. |
1.2 km (maximum) Cable resistance within 50Ω (end resistance: None or 120Ω or more on both sides) |
EIA RS-485 compliant |
Half double communication |
Select 9600, 19200, 38400 BPS by key operation |
Toning synchronization |
ASCII, binary |
|
FEB-102-Ech, EVT4 |
Available upon quote |
4 -pole conductive rate sensor (temperature element PT100 or PT1000) |
・ Conductive: ± 0.5% of measurement range span |
・ Conductive: ± 0.5% of measurement range span |
± 1 ℃ |
250 MS (2 input) |
Within ± 1%for the set time |
・ Setting accuracy: Same as instruction accuracy |
・ Control capacity: 3A 250V AC (resistance load), 1A 250V AC (induced load COSφ = 0.4) |
・ Operation ON delay timer: 0 to 10000 seconds |
・ Conductive proofreading: Calonization of zero conductive rate and conductive rate span adjustment. |
Conductive, temperature, and MV are converted to analog amount for each input sampling and output by current. (The decimal position is fixed regardless of the decimal position selection) |
・ Dusive ability: 12000 ・ Current: 4 ~ 20mA DC (maximum load resistance 550Ω) ・ Output accuracy: within ± 0.3%of transmission output span |
Motor the CPU with a watchdog timer and make the instrument into an initial state in the event of an abnormality. |
-20 ~ 50 ° C (how to adapt to the instruction accuracy at 0 to 50 ° C and avoid direct sunlight) |
35 ~ 95%RH (but not condensation) |
100 ~ 240 V AC 50/60 Hz tolerance fluctuation range: 85 ~ 264 v AC |
Approximately 10 VA |
Wall installation method |
・ Case: Polycarbonate color: Metallic gray |
IP65 |
ROHS command support |
W239.5xh190XD75mm |
Approximately 950g |
Perform the following operations from the external computer. |
1.2 km (maximum) Cable resistance within 50Ω (end resistance: None or 120Ω or more on both sides) |
EIA RS-485 compliant |
Half double communication |
Select 9600, 19200, 38400 BPS by key operation |
Toning synchronization |
ASCII, binary |
Click on the part number for more information about each product