Product
On-site conductive rate meter FEB-102-Ech (high concentration)Handling Company
Shinko Technos Co., Ltd.Items marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | Ambient temperature | Calibration function | Case, panel | Conformity standard | Drip -proof / dustproof structure | EVT output (2 points) 1 | EVT output (2 points) 2 | EVT output (2 points) 3 | External dimensions | Input sampling cycle | Linearness | Mounting method | Peripheral humidity | Repetition | Self -diagnostic function | Serial communication (Options: C5) | Serial communication (Options: C5) Communication method | Serial communication (option: C5) Certification format | Serial communication (option: C5) cable length | Serial communication (option: C5) communication line | Serial communication (option: C5) communication speed | Serial communication (option: C5) synchronous method | Temperature instruction accuracy | Time accuracy | Transmission output 1, 2-1 | Transmission output 1, 2-2 | input | mass | power consumption | power supply |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
FEB-102-Ech, C5 |
Available upon quote | -20 ~ 50 ° C (how to adapt to the instruction accuracy at 0 to 50 ° C and avoid direct sunlight) |
・ Conductive proofreading: Calonization of zero conductive rate and conductive rate span adjustment. ・ Temperature school regular (1 point) |
・ Case: Polycarbonate color: Metallic gray ・ Panel: Membrane sheet |
ROHS command support | IP65 |
・ Setting accuracy: Same as instruction accuracy ・ Output operation: P operation proportional belt other than 0, when the ON/OFF operation proportional belt is set to 0. ・ Relay contact 1A |
・ Control capacity: 3A 250V AC (resistance load), 1A 250V AC (induced load COSφ = 0.4) ・ Electrical life: 100,000 times |
・ Operation ON delay timer: 0 to 10000 seconds ・ Operation OFF delay timer: 0 to 10000 seconds |
W239.5xh190XD75mm | 250 MS (2 input) | ・ Conductive: ± 0.5%of measuring range span ・ Salt conversion: Measurement range span ± 1%・ TDS conversion: measuring range span ± 1.5% | Wall installation method | 35 ~ 95%RH (but not condensation) | ・ Conductive: ± 0.5%of measuring range span ・ Salt conversion: Measurement range span ± 1%・ TDS conversion: measuring range span ± 1.5% | Motor the CPU with a watchdog timer and make the instrument into an initial state in the event of an abnormality. |
Perform the following operations from the external computer. ・ Read and set various set values ・ Conductive, salt conversion, temperature or state reading ・ Change and adjust function |
Half double communication | ASCII, binary | 1.2 km (maximum) Cable resistance within 50Ω (end resistance: None or 120Ω or more on both sides) | EIA RS-485 compliant | Select 9600, 19200, 38400 BPS by key operation | Toning synchronization | ± 1 ℃ | Within ± 1%for the set time | Conductive, temperature, and MV are converted to analog amount for each input sampling and output by current. (The decimal position is fixed regardless of the decimal position selection) | ・ Dusive ability: 12000 ・ Current: 4 ~ 20mA DC (maximum load resistance 550Ω) ・ Output accuracy: within ± 0.3%of transmission output span | 4 -pole conductive rate sensor (temperature element PT100 or PT1000) | Approximately 950g | Approximately 10 VA | 100 ~ 240 V AC 50/60 Hz tolerance fluctuation range: 85 ~ 264 v AC | |
FEB-102-Ech, EVT3 |
Available upon quote | -20 ~ 50 ° C (how to adapt to the instruction accuracy at 0 to 50 ° C and avoid direct sunlight) |
・ Conductive proofreading: Calonization of zero conductive rate and conductive rate span adjustment. ・ Temperature school regular (1 point) |
・ Case: Polycarbonate color: Metallic gray ・ Panel: Membrane sheet |
ROHS command support | IP65 |
・ Setting accuracy: Same as instruction accuracy ・ Output operation: P operation proportional belt other than 0, when the ON/OFF operation proportional belt is set to 0. ・ Relay contact 1A |
・ Control capacity: 3A 250V AC (resistance load), 1A 250V AC (induced load COSφ = 0.4) ・ Electrical life: 100,000 times |
・ Operation ON delay timer: 0 to 10000 seconds ・ Operation OFF delay timer: 0 to 10000 seconds |
W239.5xh190XD75mm | 250 MS (2 input) |
・ Conductive: ± 0.5% of measurement range span ・ Salt conversion: ± 1% of measured range span ・ TDS conversion: ± 1.5% of measurement range span |
Wall installation method | 35 ~ 95%RH (but not condensation) |
・ Conductive: ± 0.5% of measurement range span ・ Salt conversion: ± 1% of measured range span ・ TDS conversion: ± 1.5% of measurement range span |
Motor the CPU with a watchdog timer and make the instrument into an initial state in the event of an abnormality. |
Perform the following operations from the external computer. ・ Read and set various set values ・ Conductive, salt conversion, temperature or state reading ・ Change and adjust function |
Half double communication | ASCII, binary | 1.2 km (maximum) Cable resistance within 50Ω (end resistance: None or 120Ω or more on both sides) | EIA RS-485 compliant | Select 9600, 19200, 38400 BPS by key operation | Toning synchronization | ± 1 ℃ | Within ± 1%for the set time | Conductive, temperature, and MV are converted to analog amount for each input sampling and output by current. (The decimal position is fixed regardless of the decimal position selection) | ・ Dusive ability: 12000 ・ Current: 4 ~ 20mA DC (maximum load resistance 550Ω) ・ Output accuracy: within ± 0.3%of transmission output span | 4 -pole conductive rate sensor (temperature element PT100 or PT1000) | Approximately 950g | Approximately 10 VA | 100 ~ 240 V AC 50/60 Hz tolerance fluctuation range: 85 ~ 264 v AC | |
FEB-102-Ech, EVT4 |
Available upon quote | -20 ~ 50 ° C (how to adapt to the instruction accuracy at 0 to 50 ° C and avoid direct sunlight) |
・ Conductive proofreading: Calonization of zero conductive rate and conductive rate span adjustment. ・ Temperature school regular (1 point) |
・ Case: Polycarbonate color: Metallic gray ・ Panel: Membrane sheet |
ROHS command support | IP65 |
・ Setting accuracy: Same as instruction accuracy ・ Output operation: P operation proportional belt other than 0, when the ON/OFF operation proportional belt is set to 0. ・ Relay contact 1A |
・ Control capacity: 3A 250V AC (resistance load), 1A 250V AC (induced load COSφ = 0.4) ・ Electrical life: 100,000 times |
・ Operation ON delay timer: 0 to 10000 seconds ・ Operation OFF delay timer: 0 to 10000 seconds |
W239.5xh190XD75mm | 250 MS (2 input) |
・ Conductive: ± 0.5% of measurement range span ・ Salt conversion: ± 1% of measured range span ・ TDS conversion: ± 1.5% of measurement range span |
Wall installation method | 35 ~ 95%RH (but not condensation) |
・ Conductive: ± 0.5% of measurement range span ・ Salt conversion: ± 1% of measured range span ・ TDS conversion: ± 1.5% of measurement range span |
Motor the CPU with a watchdog timer and make the instrument into an initial state in the event of an abnormality. |
Perform the following operations from the external computer. ・ Read and set various set values ・ Conductive, salt conversion, temperature or state reading ・ Change and adjust function |
Half double communication | ASCII, binary | 1.2 km (maximum) Cable resistance within 50Ω (end resistance: None or 120Ω or more on both sides) | EIA RS-485 compliant | Select 9600, 19200, 38400 BPS by key operation | Toning synchronization | ± 1 ℃ | Within ± 1%for the set time | Conductive, temperature, and MV are converted to analog amount for each input sampling and output by current. (The decimal position is fixed regardless of the decimal position selection) | ・ Dusive ability: 12000 ・ Current: 4 ~ 20mA DC (maximum load resistance 550Ω) ・ Output accuracy: within ± 0.3%of transmission output span | 4 -pole conductive rate sensor (temperature element PT100 or PT1000) | Approximately 950g | Approximately 10 VA | 100 ~ 240 V AC 50/60 Hz tolerance fluctuation range: 85 ~ 264 v AC |
Click on the part number for more information about each product