Product
Plug-in-type digital indicator derivative rate meter WIL-102-ECL (low concentration)Handling Company
Shinko Technos Co., Ltd.Items marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | Ambient temperature | Conductive proofreading | Conformity standard | External dimensions | Linearness | Peripheral humidity | Protective structure | Repetition | Self -diagnostic function | Serial communication | Serial communication and communication protocol | Serial communication cable length | Serial communication communication line | Serial communication communication method | Serial communication communication speed | Serial communication data bit/Parity | Serial communication error correction | Serial communication error detection | Serial communication format | Serial communication stop bit | Serial communication synchronous method | TDS conversion 1 | TDS conversion 2 | Temperature adjustment 1 | Temperature adjustment 2 | Temperature compensation element | Temperature compensation range | mass | power supply | structure |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
WIL-102-ECL, EVT |
Available upon quote | 0 to 50 ℃ |
・ Calonize the conductive rate zero adjustment and conductive rate span adjustment. ・ Conductive adjustment adjustment: zero adjustment coefficient setting range -10%of input span -10%of input span ・ Conductive span adjustment: Span adjustment coefficient range 0.700 ~ 1.300 |
ROHS command support | W30XH88XD108mm (including socket) |
・ Conductive: ± 0.5% of input span ・ TDS conversion: ± 1.5% of input span |
35 ~ 85%RH (but not condensation) | Over-pressure category Ⅱ, pollution 2 (IEC61010-1) |
・ Conductive: ± 0.5% of input span ・ TDS conversion: ± 1.5% of input span |
Motor the CPU with a watchdog timer and make the instrument into an initial state in the event of an abnormality. |
Perform the following operations from the external computer. ・ Read and set various set values ・ Reading of the conductive rate, temperature, and state ・ Change and adjust function ・ Reading and setting of user storage area |
Select Shinko Standard, Modbus ASCII, Modbus RTU by key operation | 1.2 km (maximum) Cable resistance within 50Ω (end resistance: None or 120Ω or more on both sides) | EIA RS-485 compliant | Half double communication | Select 9,600, 19,200, 38,400 BPS by key operation | 8 bits/none, 7 -bit/none, 8 -bit/even number, 7 -bit/even number, 8 -bit/odd, 7 -bit/odd number by key operation | Command resend |
・ Parity check, checksum (Shinko standard) ・ LRC (Modbus ASCII), CRC-16 (Modbus RTU) |
ASCII, binary | Select 1 bit and 2 bits by key operation | Toning synchronization | TDS is an abbreviation of Total Dis Orved Solids, which means full -dissolved solid volume. The conductivity of the solution is due to the amount of salt, minerals, and the amount of dissolved gas. | The conductive rate is an index indicating all the substances in the solution, and the TDS indicates only the full -mixed amount of solids. |
When the sensor cannot be installed in the area you want to measure, the temperature measured by the sensor and the temperature of the measured site The degree may be different. In such a case, the temperature school positive value can be set to match the temperature of the measurement point to the desired temperature. |
Adjustment range: -10.0 ~ 10.0 ℃ | 2 polar conductive rate sensor (temperature element: PT100), 2 polar conductive rate sensor (temperature element: PT1000) | 0.0 to 100.0 ° C | Approximately 200g (including socket) | 100 ~ 240 V AC 50/60 Hz tolerance fluctuation range: 85 ~ 264 v AC |
・ DIN rail mounting method ・ Case: flame -retardant resin color: Light gray ・ Panel: Membrane sheet |
|
WIL-102-ECL, TA |
Available upon quote | 0 to 50 ℃ |
・ Calonize the conductive rate zero adjustment and conductive rate span adjustment. ・ Conductive adjustment adjustment: zero adjustment coefficient setting range -10%of input span -10%of input span ・ Conductive span adjustment: Span adjustment coefficient range 0.700 ~ 1.300 |
ROHS command support | W30XH88XD108mm (including socket) |
・ Conductive: ± 0.5% of input span ・ TDS conversion: ± 1.5% of input span |
35 ~ 85%RH (but not condensation) | Over-pressure category Ⅱ, pollution 2 (IEC61010-1) |
・ Conductive: ± 0.5% of input span ・ TDS conversion: ± 1.5% of input span |
Motor the CPU with a watchdog timer and make the instrument into an initial state in the event of an abnormality. |
Perform the following operations from the external computer. ・ Read and set various set values ・ Reading of the conductive rate, temperature, and state ・ Change and adjust function ・ Reading and setting of user storage area |
Select Shinko Standard, Modbus ASCII, Modbus RTU by key operation | 1.2 km (maximum) Cable resistance within 50Ω (end resistance: None or 120Ω or more on both sides) | EIA RS-485 compliant | Half double communication | Select 9,600, 19,200, 38,400 BPS by key operation | 8 bits/none, 7 -bit/none, 8 -bit/even number, 7 -bit/even number, 8 -bit/odd, 7 -bit/odd number by key operation | Command resend |
・ Parity check, checksum (Shinko standard) ・ LRC (Modbus ASCII), CRC-16 (Modbus RTU) |
ASCII, binary | Select 1 bit and 2 bits by key operation | Toning synchronization | TDS is an abbreviation of Total Dis Orved Solids, which means full -dissolved solid volume. The conductivity of the solution is due to the amount of salt, minerals, and the amount of dissolved gas. | The conductive rate is an index indicating all the substances in the solution, and the TDS indicates only the full -mixed amount of solids. |
When the sensor cannot be installed in the area you want to measure, the temperature measured by the sensor and the temperature of the measured site The degree may be different. In such a case, the temperature school positive value can be set to match the temperature of the measurement point to the desired temperature. |
Adjustment range: -10.0 ~ 10.0 ℃ | 2 polar conductive rate sensor (temperature element: PT100), 2 polar conductive rate sensor (temperature element: PT1000) | 0.0 to 100.0 ° C | Approximately 200g (including socket) | 100 ~ 240 V AC 50/60 Hz tolerance fluctuation range: 85 ~ 264 v AC |
・ DIN rail mounting method ・ Case: flame -retardant resin color: Light gray ・ Panel: Membrane sheet |
|
WIL-102-ECL, TA2 |
Available upon quote | 0 to 50 ℃ | ・ Calonize the conductive rate zero adjustment and conductive rate span adjustment.・ Conductive adjustment adjustment: zero adjustment coefficient setting range -10%of input span -10%of input span ・ Conductive span adjustment: Span adjustment coefficient range 0.700 ~ 1.300 | ROHS command support | W30XH88XD108mm (including socket) |
・ Conductive: ± 0.5% of input span ・ TDS conversion: ± 1.5% of input span |
35 ~ 85%RH (but not condensation) | Over-pressure category Ⅱ, pollution 2 (IEC61010-1) | ・ Conductive rate: ± 0.5%of input span ・ TDS conversion: ± 1.5%of input span | Motor the CPU with a watchdog timer and make the instrument into an initial state in the event of an abnormality. |
Perform the following operations from the external computer. ・ Read and set various set values ・ Reading of the conductive rate, temperature, and state ・ Change and adjust function ・ Reading and setting of user storage area |
Select Shinko Standard, Modbus ASCII, Modbus RTU by key operation | 1.2 km (maximum) Cable resistance within 50Ω (end resistance: None or 120Ω or more on both sides) | EIA RS-485 compliant | Half double communication | Select 9,600, 19,200, 38,400 BPS by key operation | 8 bits/none, 7 -bit/none, 8 -bit/even number, 7 -bit/even number, 8 -bit/odd, 7 -bit/odd number by key operation | Command resend |
・ Parity check, checksum (Shinko standard) ・ LRC (Modbus ASCII), CRC-16 (Modbus RTU) |
ASCII, binary | Select 1 bit and 2 bits by key operation | Toning synchronization | TDS is an abbreviation of Total Dis Orved Solids, which means full -dissolved solid volume. The conductivity of the solution is due to the amount of salt, minerals, and the amount of dissolved gas. | The conductive rate is an index indicating all the substances in the solution, and the TDS indicates only the full -mixed amount of solids. |
When the sensor cannot be installed in the area you want to measure, the temperature measured by the sensor and the temperature of the measured site The degree may be different. In such a case, the temperature school positive value can be set to match the temperature of the measurement point to the desired temperature. |
Adjustment range: -10.0 ~ 10.0 ℃ | 2 polar conductive rate sensor (temperature element: PT100), 2 polar conductive rate sensor (temperature element: PT1000) | 0.0 to 100.0 ° C | Approximately 200g (including socket) | 100 ~ 240 V AC 50/60 Hz tolerance fluctuation range: 85 ~ 264 v AC |
・ DIN rail mounting method ・ Case: flame -retardant resin color: Light gray ・ Panel: Membrane sheet |
|
WIL-102-ECL1, EVT |
Available upon quote | 0 to 50 ℃ |
・ Calonize the conductive rate zero adjustment and conductive rate span adjustment. ・ Conductive adjustment adjustment: zero adjustment coefficient setting range -10%of input span -10%of input span ・ Conductive span adjustment: Span adjustment coefficient range 0.700 ~ 1.300 |
ROHS command support | W30XH88XD108mm (including socket) |
・ Conductive: ± 0.5% of input span ・ TDS conversion: ± 1.5% of input span |
35 ~ 85%RH (but not condensation) | Over-pressure category Ⅱ, pollution 2 (IEC61010-1) |
・ Conductive: ± 0.5% of input span ・ TDS conversion: ± 1.5% of input span |
Motor the CPU with a watchdog timer and make the instrument into an initial state in the event of an abnormality. |
Perform the following operations from the external computer. ・ Read and set various set values ・ Reading of the conductive rate, temperature, and state ・ Change and adjust function ・ Reading and setting of user storage area |
Select Shinko Standard, Modbus ASCII, Modbus RTU by key operation | 1.2 km (maximum) Cable resistance within 50Ω (end resistance: None or 120Ω or more on both sides) | EIA RS-485 compliant | Half double communication | Select 9,600, 19,200, 38,400 BPS by key operation | 8 bits/none, 7 -bit/none, 8 -bit/even number, 7 -bit/even number, 8 -bit/odd, 7 -bit/odd number by key operation | Command resend |
・ Parity check, checksum (Shinko standard) ・ LRC (Modbus ASCII), CRC-16 (Modbus RTU) |
ASCII, binary | Select 1 bit and 2 bits by key operation | Toning synchronization | TDS is an abbreviation of Total Dis Orved Solids, which means full -dissolved solid volume. The conductivity of the solution is due to the amount of salt, minerals, and the amount of dissolved gas. | The conductive rate is an index indicating all the substances in the solution, and the TDS indicates only the full -mixed amount of solids. |
When the sensor cannot be installed in the area you want to measure, the temperature measured by the sensor and the temperature of the measured site The degree may be different. In such a case, the temperature school positive value can be set to match the temperature of the measurement point to the desired temperature. |
Adjustment range: -10.0 ~ 10.0 ℃ | 2 polar conductive rate sensor (temperature element: PT100), 2 polar conductive rate sensor (temperature element: PT1000) | 0.0 to 100.0 ° C | Approximately 200g (including socket) | 24 V AC/DC 50/60 Hz Available range range: 20-28 v AC/DC |
・ DIN rail mounting method ・ Case: flame -retardant resin color: Light gray ・ Panel: Membrane sheet |
|
WIL-102-ECL1, TA |
Available upon quote | 0 to 50 ℃ |
・ Calonize the conductive rate zero adjustment and conductive rate span adjustment. ・ Conductive adjustment adjustment: zero adjustment coefficient setting range -10%of input span -10%of input span ・ Conductive span adjustment: Span adjustment coefficient range 0.700 ~ 1.300 |
ROHS command support | W30XH88XD108mm (including socket) |
・ Conductive: ± 0.5% of input span ・ TDS conversion: ± 1.5% of input span |
35 ~ 85%RH (but not condensation) | Over-pressure category Ⅱ, pollution 2 (IEC61010-1) |
・ Conductive: ± 0.5% of input span ・ TDS conversion: ± 1.5% of input span |
Motor the CPU with a watchdog timer and make the instrument into an initial state in the event of an abnormality. |
Perform the following operations from the external computer. ・ Read and set various set values ・ Reading of the conductive rate, temperature, and state ・ Change and adjust function ・ Reading and setting of user storage area |
Select Shinko Standard, Modbus ASCII, Modbus RTU by key operation | 1.2 km (maximum) Cable resistance within 50Ω (end resistance: None or 120Ω or more on both sides) | EIA RS-485 compliant | Half double communication | Select 9,600, 19,200, 38,400 BPS by key operation | 8 bits/none, 7 -bit/none, 8 -bit/even number, 7 -bit/even number, 8 -bit/odd, 7 -bit/odd number by key operation | Command resend |
・ Parity check, checksum (Shinko standard) ・ LRC (Modbus ASCII), CRC-16 (Modbus RTU) |
ASCII, binary | Select 1 bit and 2 bits by key operation | Toning synchronization | TDS is an abbreviation of Total Dis Orved Solids, which means full -dissolved solid volume. The conductivity of the solution is due to the amount of salt, minerals, and the amount of dissolved gas. | The conductive rate is an index indicating all the substances in the solution, and the TDS indicates only the full -mixed amount of solids. |
When the sensor cannot be installed in the area you want to measure, the temperature measured by the sensor and the temperature of the measured site The degree may be different. In such a case, the temperature school positive value can be set to match the temperature of the measurement point to the desired temperature. |
Adjustment range: -10.0 ~ 10.0 ℃ | 2 polar conductive rate sensor (temperature element: PT100), 2 polar conductive rate sensor (temperature element: PT1000) | 0.0 to 100.0 ° C | Approximately 200g (including socket) | 24 V AC/DC 50/60 Hz Available range range: 20-28 v AC/DC |
・ DIN rail mounting method ・ Case: flame -retardant resin color: Light gray ・ Panel: Membrane sheet |
|
WIL-102-ECL1, TA2 |
Available upon quote | 0 to 50 ℃ |
・ Calonize the conductive rate zero adjustment and conductive rate span adjustment. ・ Conductive adjustment adjustment: zero adjustment coefficient setting range -10%of input span -10%of input span ・ Conductive span adjustment: Span adjustment coefficient range 0.700 ~ 1.300 |
ROHS command support | W30XH88XD108mm (including socket) |
・ Conductive: ± 0.5% of input span ・ TDS conversion: ± 1.5% of input span |
35 ~ 85%RH (but not condensation) | Over-pressure category Ⅱ, pollution 2 (IEC61010-1) |
・ Conductive: ± 0.5% of input span ・ TDS conversion: ± 1.5% of input span |
Motor the CPU with a watchdog timer and make the instrument into an initial state in the event of an abnormality. |
Perform the following operations from the external computer. ・ Read and set various set values ・ Reading of the conductive rate, temperature, and state ・ Change and adjust function ・ Reading and setting of user storage area |
Select Shinko Standard, Modbus ASCII, Modbus RTU by key operation | 1.2 km (maximum) Cable resistance within 50Ω (end resistance: None or 120Ω or more on both sides) | EIA RS-485 compliant | Half double communication | Select 9,600, 19,200, 38,400 BPS by key operation | 8 bits/none, 7 -bit/none, 8 -bit/even number, 7 -bit/even number, 8 -bit/odd, 7 -bit/odd number by key operation | Command resend |
・ Parity check, checksum (Shinko standard) ・ LRC (Modbus ASCII), CRC-16 (Modbus RTU) |
ASCII, binary | Select 1 bit and 2 bits by key operation | Toning synchronization | TDS is an abbreviation of Total Dis Orved Solids, which means full -dissolved solid volume. The conductivity of the solution is due to the amount of salt, minerals, and the amount of dissolved gas. | The conductive rate is an index indicating all the substances in the solution, and the TDS indicates only the full -mixed amount of solids. |
When the sensor cannot be installed in the area you want to measure, the temperature measured by the sensor and the temperature of the measured site The degree may be different. In such a case, the temperature school positive value can be set to match the temperature of the measurement point to the desired temperature. |
Adjustment range: -10.0 ~ 10.0 ℃ | 2 polar conductive rate sensor (temperature element: PT100), 2 polar conductive rate sensor (temperature element: PT1000) | 0.0 to 100.0 ° C | Approximately 200g (including socket) | 24 V AC/DC 50/60 Hz Available range range: 20-28 v AC/DC |
・ DIN rail mounting method ・ Case: flame -retardant resin color: Light gray ・ Panel: Membrane sheet |
Click on the part number for more information about each product