On-site conductive rate meter FEB-102-ECM (low concentration)-FEB-102-ECM, C5
On-site conductive rate meter FEB-102-ECM (low concentration)-Shinko Technos Co., Ltd.

On-site conductive rate meter FEB-102-ECM (low concentration)
Shinko Technos Co., Ltd.


About This Product

It is a type of on -site conductor that is installed on the wall that supports various applications such as drug concentration management, cleaning water management, pure water management, and drainage management. ・ Equipped with 2 points in contact with contact (EVT output) and 2 points (transmission output) ・ Communication (RS-485) (optional) ・ Dustproof / drip -proof structure IP65: Compatible with outdoor use

  • Product

    On-site conductive rate meter FEB-102-ECM (low concentration)




*Please note that we may not be able to accommodate sample requests.

3 Models of On-site conductive rate meter FEB-102-ECM (low concentration)

Items marked with have different values ​​depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Ambient temperature Calibration function Case, panel Conformity standard Drip -proof / dustproof structure EVT output (2 points) 1 EVT output (2 points) 2 EVT output (2 points) 3 External dimensions Input sampling cycle Linearness Mounting method Peripheral humidity Repetition Self -diagnostic function Serial communication (Options: C5) Serial communication (Options: C5) Communication method Serial communication (option: C5) Certification format Serial communication (option: C5) cable length Serial communication (option: C5) communication line Serial communication (option: C5) communication speed Serial communication (option: C5) synchronous method Temperature instruction accuracy Time accuracy Transmission output 1, 2-1 Transmission output 1, 2-2 input mass power consumption power supply
On-site conductive rate meter FEB-102-ECM (low concentration)-Part Number-FEB-102-ECM, C5

FEB-102-ECM, C5

Available upon quote -20 ~ 50 ° C (how to adapt to the instruction accuracy at 0 to 50 ° C and avoid direct sunlight) ・ Conductive proofreading: Calonization of zero conductive rate and conductive rate span adjustment.
・ Temperature school regular (1 point)
・ Case: Polycarbonate color: Metallic gray
・ Panel: Membrane sheet
ROHS command support IP65 ・ Configuration accuracy: Same as instruction accuracy ・ Output operation: P operation If the proportional belt is set to 0, ON/OFF operation proportional belt is set to 0 ・ Relay contact 1A ・ Control capacity: 3A 250V AC (resistance load), 1A 250V AC (induced load COSφ = 0.4) ・ Electrical life: 100,000 times ・ Operation ON delay timer: 0 to 10000 seconds
・ Operation OFF delay timer: 0 to 10000 seconds
W239.5xh190XD75mm 250 MS (2 input) ・ Conductive rate: ± 0.5%of measurement range span ・ TDS conversion: Measurement range ± 1.5% Wall installation method 35 ~ 95%RH (but not condensation) ・ Conductive rate: ± 0.5%of measurement range span ・ TDS conversion: Measurement range ± 1.5% Motor the CPU with a watchdog timer and make the instrument into an initial state in the event of an abnormality. Perform the following operations from the external computer.・ Reading and adjustment of various set values, setting / conductive rate, temperature or state read / function change, adjustment Half double communication ASCII, binary 1.2 km (maximum) Cable resistance within 50Ω (end resistance: None or 120Ω or more on both sides) EIA RS-485 compliant Select 9600, 19200, 38400 BPS by key operation Toning synchronization ± 1 ℃ Within ± 1%for the set time Conductive, temperature, and MV are converted to analog amount for each input sampling and output by current. (The decimal position is fixed regardless of the decimal position selection) ・ Dusive ability: 12000 ・ Current: 4 ~ 20mA DC (maximum load resistance 550Ω) ・ Output accuracy: within ± 0.3%of transmission output span Two -pole conductive rate sensor (temperature element PT100 or PT1000) Approximately 950g Approximately 10 VA 100 ~ 240 V AC 50/60 Hz tolerance fluctuation range: 85 ~ 264 v AC
On-site conductive rate meter FEB-102-ECM (low concentration)-Part Number-FEB-102-ECM, EVT3

FEB-102-ECM, EVT3

Available upon quote -20 ~ 50 ° C (how to adapt to the instruction accuracy at 0 to 50 ° C and avoid direct sunlight) ・ Conductive proofreading: Calonization of zero conductive rate and conductive rate span adjustment.
・ Temperature school regular (1 point)
・ Case: Polycarbonate color: Metallic gray
・ Panel: Membrane sheet
ROHS command support IP65 ・ Setting accuracy: Same as instruction accuracy
・ Output operation: P operation proportional belt other than 0, when the ON/OFF operation proportional belt is set to 0.
・ Relay contact 1A
・ Control capacity: 3A 250V AC (resistance load), 1A 250V AC (induced load COSφ = 0.4)
・ Electrical life: 100,000 times
・ Operation ON delay timer: 0 to 10000 seconds
・ Operation OFF delay timer: 0 to 10000 seconds
W239.5xh190XD75mm 250 MS (2 input) ・ Conductive: ± 0.5% of measurement range span
・ TDS conversion: ± 1.5% of measurement range span
Wall installation method 35 ~ 95%RH (but not condensation) ・ Conductive: ± 0.5% of measurement range span
・ TDS conversion: ± 1.5% of measurement range span
Motor the CPU with a watchdog timer and make the instrument into an initial state in the event of an abnormality. Perform the following operations from the external computer.
・ Read and set various set values
・ Reading the conductive rate, temperature or state
・ Change and adjust function
Half double communication ASCII, binary 1.2 km (maximum) Cable resistance within 50Ω (end resistance: None or 120Ω or more on both sides) EIA RS-485 compliant Select 9600, 19200, 38400 BPS by key operation Toning synchronization ± 1 ℃ Within ± 1%for the set time Conductive, temperature, and MV are converted to analog amount for each input sampling and output by current. (The decimal position is fixed regardless of the decimal position selection) ・ Dusive ability: 12000 ・ Current: 4 ~ 20mA DC (maximum load resistance 550Ω) ・ Output accuracy: within ± 0.3%of transmission output span Two -pole conductive rate sensor (temperature element PT100 or PT1000) Approximately 950g Approximately 10 VA 100 ~ 240 V AC 50/60 Hz tolerance fluctuation range: 85 ~ 264 v AC
On-site conductive rate meter FEB-102-ECM (low concentration)-Part Number-FEB-102-ECM, EVT4

FEB-102-ECM, EVT4

Available upon quote -20 ~ 50 ° C (how to adapt to the instruction accuracy at 0 to 50 ° C and avoid direct sunlight) ・ Conductive proofreading: Calonization of zero conductive rate and conductive rate span adjustment.
・ Temperature school regular (1 point)
・ Case: Polycarbonate color: Metallic gray
・ Panel: Membrane sheet
ROHS command support IP65 ・ Setting accuracy: Same as instruction accuracy
・ Output operation: P operation proportional belt other than 0, when the ON/OFF operation proportional belt is set to 0.
・ Relay contact 1A
・ Control capacity: 3A 250V AC (resistance load), 1A 250V AC (induced load COSφ = 0.4)
・ Electrical life: 100,000 times
・ Operation ON delay timer: 0 to 10000 seconds
・ Operation OFF delay timer: 0 to 10000 seconds
W239.5xh190XD75mm 250 MS (2 input) ・ Conductive: ± 0.5% of measurement range span
・ TDS conversion: ± 1.5% of measurement range span
Wall installation method 35 ~ 95%RH (but not condensation) ・ Conductive: ± 0.5% of measurement range span
・ TDS conversion: ± 1.5% of measurement range span
Motor the CPU with a watchdog timer and make the instrument into an initial state in the event of an abnormality. Perform the following operations from the external computer.
・ Read and set various set values
・ Reading the conductive rate, temperature or state
・ Change and adjust function
Half double communication ASCII, binary 1.2 km (maximum) Cable resistance within 50Ω (end resistance: None or 120Ω or more on both sides) EIA RS-485 compliant Select 9600, 19200, 38400 BPS by key operation Toning synchronization ± 1 ℃ Within ± 1%for the set time Conductive, temperature, and MV are converted to analog amount for each input sampling and output by current. (The decimal position is fixed regardless of the decimal position selection) ・ Dusive ability: 12000 ・ Current: 4 ~ 20mA DC (maximum load resistance 550Ω) ・ Output accuracy: within ± 0.3%of transmission output span Two -pole conductive rate sensor (temperature element PT100 or PT1000) Approximately 950g Approximately 10 VA 100 ~ 240 V AC 50/60 Hz tolerance fluctuation range: 85 ~ 264 v AC

Click on the part number for more information about each product

Customers who viewed this product also viewed

Other products of Shinko Technos Co., Ltd.


View more products of Shinko Technos Co., Ltd.

About Company Handling This Product

Shinko Technos Co., Ltd.

  • Japan
  • Since 1945
  • 185 employees

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree