Product Image | Part Number | Price (excluding tax) | Ambient temperature | Applied load | Attached function gradient setting function | Attached function lower limit setting function | Included function software start time setting | Input resistance | Insulation resistance | Minimum load current | Mounting method | Other features | Output range | Output setting range | Peripheral humidity | Rated current | Rated frequency | Rated voltage | Withstand voltage | accessories | control method | input signal | mass |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
PA-3020-Hz |
Available upon quote |
-15 ~ 55 ° C (operation guarantee), 0 to 40 ° C (performance guarantee) |
Resistance load, inducing load (transformer primary side control, magnetic flux density of 1.25t or less, only phase control method) | The output gradient can be set to the input signal by the internal volume. It is also possible to attach the gradient setting device externally. |
By the internal volume, the output change width can be varied for the on -off setting input signal, and detailed control is possible. It is also possible to attach the lower limit configuration externally. |
By setting the soft start / soft -up and down time, it can respond to sudden changes in the load voltage, sudden changes in input signal, etc., reducing overload to the load, such as overcurrent occurrence. | 100Ω (4 ~ 20mA DC), 25kΩ (1 ~ 5V DC) | 500V DC 20mΩ or more between the power supply terminal and the case | 0.5A (output 98%) | Surface mounting method |
Soft start / soft -up -down (1 to 20 second variable), soft start when the instant stop is returned |
0 to 98% of rated voltage |
・ Slope setting (0 to 100%) ・ Lower setting (0 to 100%) |
30-90%RH | 20A |
・ 50/60Hz (automatic switching) ・ Available frequency fluctuation rated frequency ± 2Hz (operation guarantee), ± 1Hz (performance guarantee) |
・ 100 ~ 120V AC and 200 ~ 240V AC ・ The 100V system and the 200V system are shared (terminal switching) ・ 90-110% of the permissive voltage fluctuation range rated voltage |
2000V AC 1 minute between the power supply terminal and ground (heat dissipation fin) |
1 part of the instruction manual | Phase control/minute control (switching by internal switch) | DC current 4 ~ 20mA DC, DC voltage 1 ~ 5V DC or on -off point signal (switched by terminal) | Approximately 1.0kg | |
PA-3030-Hz |
Available upon quote |
-15 ~ 55 ° C (operation guarantee), 0 to 40 ° C (performance guarantee) |
Resistance load, inducing load (transformer primary side control, magnetic flux density of 1.25t or less, only phase control method) | The output gradient can be set to the input signal by the internal volume. It is also possible to attach the gradient setting device externally. |
By the internal volume, the output change width can be varied for the on -off setting input signal, and detailed control is possible. It is also possible to attach the lower limit configuration externally. |
By setting the soft start / soft -up and down time, it can respond to sudden changes in the load voltage, sudden changes in input signal, etc., reducing overload to the load, such as overcurrent occurrence. | 100Ω (4 ~ 20mA DC), 25kΩ (1 ~ 5V DC) | 500V DC 20mΩ or more between the power supply terminal and the case | 0.5A (output 98%) | Surface mounting method |
Soft start / soft -up -down (1 to 20 second variable), soft start when the instant stop is returned |
0 to 98% of rated voltage |
・ Slope setting (0 to 100%) ・ Lower setting (0 to 100%) |
30-90%RH | 30A |
・ 50/60Hz (automatic switching) ・ Available frequency fluctuation rated frequency ± 2Hz (operation guarantee), ± 1Hz (performance guarantee) |
・ 100 ~ 120V AC and 200 ~ 240V AC ・ The 100V system and the 200V system are shared (terminal switching) ・ 90-110% of the permissive voltage fluctuation range rated voltage |
2000V AC 1 minute between the power supply terminal and ground (heat dissipation fin) |
1 part of the instruction manual | Phase control/minute control (switching by internal switch) | DC current 4 ~ 20mA DC, DC voltage 1 ~ 5V DC or on -off point signal (switched by terminal) | Approximately 1.0kg | |
PA-3040-Hz |
Available upon quote |
-15 ~ 55 ° C (operation guarantee), 0 to 40 ° C (performance guarantee) |
Resistance load, inducing load (transformer primary side control, magnetic flux density of 1.25t or less, only phase control method) | The output gradient can be set to the input signal by the internal volume. It is also possible to attach the gradient setting device externally. |
By the internal volume, the output change width can be varied for the on -off setting input signal, and detailed control is possible. It is also possible to attach the lower limit configuration externally. |
By setting the soft start / soft -up and down time, it can respond to sudden changes in the load voltage, sudden changes in input signal, etc., reducing overload to the load, such as overcurrent occurrence. | 100Ω (4 ~ 20mA DC), 25kΩ (1 ~ 5V DC) | 500V DC 20mΩ or more between the power supply terminal and the case | 0.5A (output 98%) | Surface mounting method |
Soft start / soft -up -down (1 to 20 second variable), soft start when the instant stop is returned |
0 to 98% of rated voltage |
・ Slope setting (0 to 100%) ・ Lower setting (0 to 100%) |
30-90%RH | 40A |
・ 50/60Hz (automatic switching) ・ Available frequency fluctuation rated frequency ± 2Hz (operation guarantee), ± 1Hz (performance guarantee) |
・ 100 ~ 120V AC and 200 ~ 240V AC ・ The 100V system and the 200V system are shared (terminal switching) ・ 90-110% of the permissive voltage fluctuation range rated voltage |
2000V AC 1 minute between the power supply terminal and ground (heat dissipation fin) |
1 part of the instruction manual | Phase control/minute control (switching by internal switch) | DC current 4 ~ 20mA DC, DC voltage 1 ~ 5V DC or on -off point signal (switched by terminal) | Approximately 1.3kg | |
PA-3050-Hz |
Available upon quote |
-15 ~ 55 ° C (operation guarantee), 0 to 40 ° C (performance guarantee) |
Resistance load, inducing load (transformer primary side control, magnetic flux density of 1.25t or less, only phase control method) | The output gradient can be set to the input signal by the internal volume. It is also possible to attach the gradient setting device externally. |
By the internal volume, the output change width can be varied for the on -off setting input signal, and detailed control is possible. It is also possible to attach the lower limit configuration externally. |
By setting the soft start / soft -up and down time, it can respond to sudden changes in the load voltage, sudden changes in input signal, etc., reducing overload to the load, such as overcurrent occurrence. | 100Ω (4 ~ 20mA DC), 25kΩ (1 ~ 5V DC) | 500V DC 20mΩ or more between the power supply terminal and the case | 0.5A (output 98%) | Surface mounting method |
Soft start / soft -up -down (1 to 20 second variable), soft start when the instant stop is returned |
0 to 98% of rated voltage |
・ Slope setting (0 to 100%) ・ Lower setting (0 to 100%) |
30-90%RH | 50A |
・ 50/60Hz (automatic switching) ・ Available frequency fluctuation rated frequency ± 2Hz (operation guarantee), ± 1Hz (performance guarantee) |
・ 100 ~ 120V AC and 200 ~ 240V AC ・ The 100V system and the 200V system are shared (terminal switching) ・ 90-110% of the permissive voltage fluctuation range rated voltage |
2000V AC 1 minute between the power supply terminal and ground (heat dissipation fin) |
1 part of the instruction manual | Phase control/minute control (switching by internal switch) | DC current 4 ~ 20mA DC, DC voltage 1 ~ 5V DC or on -off point signal (switched by terminal) | Approximately 1.3kg | |
PA-3075-Hz |
Available upon quote |
-15 ~ 55 ° C (operation guarantee), 0 to 40 ° C (performance guarantee) |
Resistance load, inducing load (transformer primary side control, magnetic flux density of 1.25t or less, only phase control method) | The output gradient can be set to the input signal by the internal volume. It is also possible to attach the gradient setting device externally. |
By the internal volume, the output change width can be varied for the on -off setting input signal, and detailed control is possible. It is also possible to attach the lower limit configuration externally. |
By setting the soft start / soft -up and down time, it can respond to sudden changes in the load voltage, sudden changes in input signal, etc., reducing overload to the load, such as overcurrent occurrence. | 100Ω (4 ~ 20mA DC), 25kΩ (1 ~ 5V DC) | 500V DC 20mΩ or more between the power supply terminal and the case | 0.5A (output 98%) | Surface mounting method |
Soft start / soft -up -down (1 to 20 second variable), soft start when the instant stop is returned |
0 to 98% of rated voltage |
・ Slope setting (0 to 100%) ・ Lower setting (0 to 100%) |
30-90%RH | 75A |
・ 50/60Hz (automatic switching) ・ Available frequency fluctuation rated frequency ± 2Hz (operation guarantee), ± 1Hz (performance guarantee) |
・ 100 ~ 120V AC and 200 ~ 240V AC ・ The 100V system and the 200V system are shared (terminal switching) ・ 90-110% of the permissive voltage fluctuation range rated voltage |
2000V AC 1 minute between the power supply terminal and ground (heat dissipation fin) |
1 part of the instruction manual | Phase control/minute control (switching by internal switch) | DC current 4 ~ 20mA DC, DC voltage 1 ~ 5V DC or on -off point signal (switched by terminal) | Approximately 1.9kg | |
PA-3100-Hz |
Available upon quote |
-15 ~ 55 ° C (operation guarantee), 0 to 40 ° C (performance guarantee) |
Resistance load, inducing load (transformer primary side control, magnetic flux density of 1.25t or less, only phase control method) | The output gradient can be set to the input signal by the internal volume. It is also possible to attach the gradient setting device externally. |
By the internal volume, the output change width can be varied for the on -off setting input signal, and detailed control is possible. It is also possible to attach the lower limit configuration externally. |
By setting the soft start / soft -up and down time, it can respond to sudden changes in the load voltage, sudden changes in input signal, etc., reducing overload to the load, such as overcurrent occurrence. | 100Ω (4 ~ 20mA DC), 25kΩ (1 ~ 5V DC) | 500V DC 20mΩ or more between the power supply terminal and the case | 0.5A (output 98%) | Surface mounting method |
Soft start / soft -up -down (1 to 20 second variable), soft start when the instant stop is returned |
0 to 98% of rated voltage |
・ Slope setting (0 to 100%) ・ Lower setting (0 to 100%) |
30-90%RH | 100A |
・ 50/60Hz (automatic switching) ・ Available frequency fluctuation rated frequency ± 2Hz (operation guarantee), ± 1Hz (performance guarantee) |
・ 100 ~ 120V AC and 200 ~ 240V AC ・ The 100V system and the 200V system are shared (terminal switching) ・ 90-110% of the permissive voltage fluctuation range rated voltage |
2000V AC 1 minute between the power supply terminal and ground (heat dissipation fin) |
1 part of the instruction manual | Phase control/minute control (switching by internal switch) | DC current 4 ~ 20mA DC, DC voltage 1 ~ 5V DC or on -off point signal (switched by terminal) | Approximately 1.9kg |