Price (excluding tax)
You can search for other models from each index. The displayed value is the value of the currently selected part number.
Ambient temperature
Applied load
Attached function gradient setting function
Attached function lower limit setting function
Included function software start time setting
Input resistance
Insulation resistance
Minimum load current
Mounting method
Other features
Output range
Output setting range
Peripheral humidity
Rated current
Rated frequency
Rated voltage
Withstand voltage
accessories
control method
input signal
mass
Part Number
PA-3050-HzHandling Company
Shinko Technos Co., Ltd.Items marked with have different values depending on the model number.
Product Image | Price (excluding tax) | Ambient temperature | Applied load | Attached function gradient setting function | Attached function lower limit setting function | Included function software start time setting | Input resistance | Insulation resistance | Minimum load current | Mounting method | Other features | Output range | Output setting range | Peripheral humidity | Rated current | Rated frequency | Rated voltage | Withstand voltage | accessories | control method | input signal | mass |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Available upon quote | -15 ~ 55 ° C (operation guarantee), 0 to 40 ° C (performance guarantee) | Resistance load, inducing load (transformer primary side control, magnetic flux density of 1.25t or less, only phase control method) | The output gradient can be set to the input signal by the internal volume. It is also possible to attach the gradient setting device externally. | By the internal volume, the output change width can be varied for the on -off setting input signal, and detailed control is possible. It is also possible to attach the lower limit configuration externally. | By setting the soft start / soft -up and down time, it can respond to sudden changes in the load voltage, sudden changes in input signal, etc., reducing overload to the load, such as overcurrent occurrence. | 100Ω (4 ~ 20mA DC), 25kΩ (1 ~ 5V DC) | 500V DC 20mΩ or more between the power supply terminal and the case | 0.5A (output 98%) | Surface mounting method | Soft start / soft -up -down (1 to 20 second variable), soft start when the instant stop is returned | 0 to 98% of rated voltage | ・ Slope setting (0 to 100%) ・ Lower setting (0 to 100%) | 30-90%RH | 50A | ・ 50/60Hz (automatic switching) ・ Available frequency fluctuation rated frequency ± 2Hz (operation guarantee), ± 1Hz (performance guarantee) | ・ 100 ~ 120V AC and 200 ~ 240V AC ・ The 100V system and the 200V system are shared (terminal switching) ・ 90-110% of the permissive voltage fluctuation range rated voltage | 2000V AC 1 minute between the power supply terminal and ground (heat dissipation fin) | 1 part of the instruction manual | Phase control/minute control (switching by internal switch) | DC current 4 ~ 20mA DC, DC voltage 1 ~ 5V DC or on -off point signal (switched by terminal) | Approximately 1.3kg |