Model Description

・ Input number: 2 points ・ Input: 2 -pole conductive rate sensor (temperature element PT100) / (temperature element PT1000) ・ Demation: High concentration ・ Power supply voltage: 100-240 V AC (standard) ・ Options: 2 points of contact output


Model Filter

You can search for other models from each index. The displayed value is the value of the currently selected part number.

Ambient temperature

Conductive proofreading

Conformity standard

External dimensions

Linearness

Peripheral humidity

Protective structure

Repetition

Self -diagnostic function

Serial communication

Serial communication and communication protocol

Serial communication cable length

Serial communication communication line

Serial communication communication method

Serial communication communication speed

Serial communication data bit/Parity

Serial communication error correction

Serial communication error detection

Serial communication format

Serial communication stop bit

Serial communication synchronous method

TDS conversion 1

TDS conversion 2

Temperature adjustment 1

Temperature adjustment 2

Temperature compensation element

Temperature compensation range

mass

power supply

structure

See all 6 models in list
  • Part Number

    WIL-102-ECL, EVT




*Please note that we may not be able to accommodate sample requests.

Plug-in-type digital indicator derivative rate meter WIL-102-ECL (low concentration) WIL-102-ECL, EVT's performance table

Items marked with have different values ​​depending on the model number.

Product Image Price (excluding tax) Ambient temperature Conductive proofreading Conformity standard External dimensions Linearness Peripheral humidity Protective structure Repetition Self -diagnostic function Serial communication Serial communication and communication protocol Serial communication cable length Serial communication communication line Serial communication communication method Serial communication communication speed Serial communication data bit/Parity Serial communication error correction Serial communication error detection Serial communication format Serial communication stop bit Serial communication synchronous method TDS conversion 1 TDS conversion 2 Temperature adjustment 1 Temperature adjustment 2 Temperature compensation element Temperature compensation range mass power supply structure
Plug-in-type digital indicator derivative rate meter WIL-102-ECL (low concentration)-Part Number-WIL-102-ECL, EVT Available upon quote 0 to 50 ℃ ・ Calonize the conductive rate zero adjustment and conductive rate span adjustment. ・ Conductive adjustment adjustment: zero adjustment coefficient setting range -10%of input span -10%of input span ・ Conductive span adjustment: Span adjustment coefficient range 0.700 ~ 1.300 ROHS command support W30XH88XD108mm (including socket) ・ Conductive: ± 0.5% of input span ・ TDS conversion: ± 1.5% of input span 35 ~ 85%RH (but not condensation) Over-pressure category Ⅱ, pollution 2 (IEC61010-1) ・ Conductive: ± 0.5% of input span ・ TDS conversion: ± 1.5% of input span Motor the CPU with a watchdog timer and make the instrument into an initial state in the event of an abnormality. Perform the following operations from the external computer. ・ Read and set various set values ・ Reading of the conductive rate, temperature, and state ・ Change and adjust function ・ Reading and setting of user storage area Select Shinko Standard, Modbus ASCII, Modbus RTU by key operation 1.2 km (maximum) Cable resistance within 50Ω (end resistance: None or 120Ω or more on both sides) EIA RS-485 compliant Half double communication Select 9,600, 19,200, 38,400 BPS by key operation 8 bits/none, 7 -bit/none, 8 -bit/even number, 7 -bit/even number, 8 -bit/odd, 7 -bit/odd number by key operation Command resend ・ Parity check, checksum (Shinko standard) ・ LRC (Modbus ASCII), CRC-16 (Modbus RTU) ASCII, binary Select 1 bit and 2 bits by key operation Toning synchronization TDS is an abbreviation of Total Dis Orved Solids, which means full -dissolved solid volume. The conductivity of the solution is due to the amount of salt, minerals, and the amount of dissolved gas. The conductive rate is an index indicating all the substances in the solution, and the TDS indicates only the full -mixed amount of solids. When the sensor cannot be installed in the area you want to measure, the temperature measured by the sensor and the temperature of the measured site The degree may be different. In such a case, the temperature school positive value can be set to match the temperature of the measurement point to the desired temperature. Adjustment range: -10.0 ~ 10.0 ℃ 2 polar conductive rate sensor (temperature element: PT100), 2 polar conductive rate sensor (temperature element: PT1000) 0.0 to 100.0 ° C Approximately 200g (including socket) 100 ~ 240 V AC 50/60 Hz tolerance fluctuation range: 85 ~ 264 v AC ・ DIN rail mounting method ・ Case: flame -retardant resin color: Light gray ・ Panel: Membrane sheet

There are 6 models for this product.

Customers who viewed this product also viewed

Other products of Shinko Technos Co., Ltd.


View more products of Shinko Technos Co., Ltd.

About Company Handling This Product

Shinko Technos Co., Ltd.

  • Japan
  • Since 1945
  • 185 employees

Category of this product

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree