On-site conductive rate meter FEB-102-Ech (high concentration)-Shinko Technos Co., Ltd.

FEB-102-Ech, C5 | On-site conductive rate meter FEB-102-Ech (high concentration)
Shinko Technos Co., Ltd.


Price (excluding tax)

Estimate Required


Model Description

・ Input number: 2 points ・ Input: 4 -pole conductive rate sensor (temperature element PT100 or PT1000) ・ Demation: High concentration ・ Power supply voltage: 100-240V AC ・ Options: Serial communication RS-485


Model Filter

You can search for other models from each index. The displayed value is the value of the currently selected part number.

Ambient temperature

Calibration function

Case, panel

Conformity standard

Drip -proof / dustproof structure

EVT output (2 points) 1

EVT output (2 points) 2

EVT output (2 points) 3

External dimensions

Input sampling cycle

Linearness

Mounting method

Peripheral humidity

Repetition

Self -diagnostic function

Serial communication (Options: C5)

Serial communication (Options: C5) Communication method

Serial communication (option: C5) Certification format

Serial communication (option: C5) cable length

Serial communication (option: C5) communication line

Serial communication (option: C5) communication speed

Serial communication (option: C5) synchronous method

Temperature instruction accuracy

Time accuracy

Transmission output 1, 2-1

Transmission output 1, 2-2

input

mass

power consumption

power supply

See all 3 models in list
  • Part Number

    FEB-102-Ech, C5




*Please note that we may not be able to accommodate sample requests.

On-site conductive rate meter FEB-102-Ech (high concentration) FEB-102-Ech, C5's performance table

Items marked with have different values ​​depending on the model number.

Product Image Price (excluding tax) Ambient temperature Calibration function Case, panel Conformity standard Drip -proof / dustproof structure EVT output (2 points) 1 EVT output (2 points) 2 EVT output (2 points) 3 External dimensions Input sampling cycle Linearness Mounting method Peripheral humidity Repetition Self -diagnostic function Serial communication (Options: C5) Serial communication (Options: C5) Communication method Serial communication (option: C5) Certification format Serial communication (option: C5) cable length Serial communication (option: C5) communication line Serial communication (option: C5) communication speed Serial communication (option: C5) synchronous method Temperature instruction accuracy Time accuracy Transmission output 1, 2-1 Transmission output 1, 2-2 input mass power consumption power supply
On-site conductive rate meter FEB-102-Ech (high concentration)-Part Number-FEB-102-Ech, C5 Available upon quote -20 ~ 50 ° C (how to adapt to the instruction accuracy at 0 to 50 ° C and avoid direct sunlight) ・ Conductive proofreading: Calonization of zero conductive rate and conductive rate span adjustment. ・ Temperature school regular (1 point) ・ Case: Polycarbonate color: Metallic gray ・ Panel: Membrane sheet ROHS command support IP65 ・ Setting accuracy: Same as instruction accuracy ・ Output operation: P operation proportional belt other than 0, when the ON/OFF operation proportional belt is set to 0. ・ Relay contact 1A ・ Control capacity: 3A 250V AC (resistance load), 1A 250V AC (induced load COSφ = 0.4) ・ Electrical life: 100,000 times ・ Operation ON delay timer: 0 to 10000 seconds ・ Operation OFF delay timer: 0 to 10000 seconds W239.5xh190XD75mm 250 MS (2 input) ・ Conductive: ± 0.5%of measuring range span ・ Salt conversion: Measurement range span ± 1%・ TDS conversion: measuring range span ± 1.5% Wall installation method 35 ~ 95%RH (but not condensation) ・ Conductive: ± 0.5%of measuring range span ・ Salt conversion: Measurement range span ± 1%・ TDS conversion: measuring range span ± 1.5% Motor the CPU with a watchdog timer and make the instrument into an initial state in the event of an abnormality. Perform the following operations from the external computer. ・ Read and set various set values ・ Conductive, salt conversion, temperature or state reading ・ Change and adjust function Half double communication ASCII, binary 1.2 km (maximum) Cable resistance within 50Ω (end resistance: None or 120Ω or more on both sides) EIA RS-485 compliant Select 9600, 19200, 38400 BPS by key operation Toning synchronization ± 1 ℃ Within ± 1%for the set time Conductive, temperature, and MV are converted to analog amount for each input sampling and output by current. (The decimal position is fixed regardless of the decimal position selection) ・ Dusive ability: 12000 ・ Current: 4 ~ 20mA DC (maximum load resistance 550Ω) ・ Output accuracy: within ± 0.3%of transmission output span 4 -pole conductive rate sensor (temperature element PT100 or PT1000) Approximately 950g Approximately 10 VA 100 ~ 240 V AC 50/60 Hz tolerance fluctuation range: 85 ~ 264 v AC

There are 3 models for this product.

Customers who viewed this product also viewed

Other products of Shinko Technos Co., Ltd.


View more products of Shinko Technos Co., Ltd.

About Company Handling This Product

Shinko Technos Co., Ltd.

  • Japan
  • Since 1945
  • 185 employees

Category of this product

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree