Hybrid recorder HR-700 series-HR-701
Hybrid recorder HR-700 series-Shinko Technos Co., Ltd.

Hybrid recorder HR-700 series
Shinko Technos Co., Ltd.


About This Product

■ Compact size Compact size with 150mm depth and 1.5kg of mass. ■ Communication function standard equipment RS-232C communication interface is standard equipment. ■ The display is large and easy to see A large LED with a character height of 18mm is adopted, making it easier to see the display. ■ IP65 It is a front IP65 structure that can withstand food and firing furnace in bad environments. (Dustproof, convergence IEC60529 IP65) ■ Safety standard support I have acquired CE marking. * There are other model numbers

  • Product

    Hybrid recorder HR-700 series




*Please note that we may not be able to accommodate sample requests.

9 Models of Hybrid recorder HR-700 series

Items marked with have different values ​​depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Alarm function Communication interface Digital accuracy rating Number of input points Power-supply voltage Recording accuracy Recording cycle Recording method Recording paper input option
Hybrid recorder HR-700 series-Part Number-HR-701

HR-701

Available upon quote There is no warning output, but the ALM indicator lights light. (If an alarm is required, an option is required.) The number of warnings is set for each channel with a maximum (2 points) and the lower limit (2 points). RS-232C (1200/2400/4800/9600/19200/38400bps) ± 0.2 % ± 1 digit or less 1point 100 ~ 240V AC 50/60Hz Measurement accuracy ± (0.3 % of record span) - Disposable felt pen The recording width is 100mm and the length of the record paper is 16m. Thermotical electricity, measuring temperature resistor, DC current, DC voltage -
Hybrid recorder HR-700 series-Part Number-HR-702

HR-702

Available upon quote There is no warning output, but the ALM indicator lights light. (If an alarm is required, an option is required.) The number of warnings is set for each channel with a maximum (2 points) and the lower limit (2 points). RS-232C (1200/2400/4800/9600/19200/38400bps) ± 0.2 % ± 1 digit or less 2 points 100 ~ 240V AC 50/60Hz Measurement accuracy ± (0.3 % of record span) - Disposable felt pen The recording width is 100mm and the length of the record paper is 16m. Thermotical electricity, measuring temperature resistor, DC current, DC voltage -
Hybrid recorder HR-700 series-Part Number-HR-706

HR-706

Available upon quote There is no warning output, but the ALM indicator lights light. (If an alarm is required, an option is required.) The number of warnings is set for each channel with a maximum (2 points) and the lower limit (2 points). RS-232C (1200/2400/4800/9600/19200/38400bps) ± 0.2 % ± 1 digit or less Six points 100 ~ 240V AC 50/60Hz Measurement accuracy ± (0.3 % of record span) ・ Wired dot ・ Approximately 10 seconds (record cycle can be selected by setting) - The recording width is 100mm and the length of the record paper is 16m. Thermotical electricity, measuring temperature resistor, DC current, DC voltage -
Hybrid recorder HR-700 series-Part Number-HR-701, C5

HR-701, C5

Available upon quote There is no warning output, but the ALM indicator lights light. (If an alarm is required, an option is required.) The number of warnings is set for each channel with a maximum (2 points) and the lower limit (2 points). RS-485 (1200/2400/4800/9600/19200/38400 BPS) ± 0.2 % ± 1 digit or less 1point 100 ~ 240V AC 50/60Hz Measurement accuracy ± (0.3 % of record span) - Disposable felt pen The recording width is 100mm and the length of the record paper is 16m. Thermotical electricity, measuring temperature resistor, DC current, DC voltage Communication function (RS-485)
Hybrid recorder HR-700 series-Part Number-HR-702, C5

HR-702, C5

Available upon quote There is no warning output, but the ALM indicator lights light. (If an alarm is required, an option is required.) The number of warnings is set for each channel with a maximum (2 points) and the lower limit (2 points). RS-485 (1200/2400/4800/9600/19200/38400bps) ± 0.2 % ± 1 digit or less 2 points 100 ~ 240V AC 50/60Hz Measurement accuracy ± (0.3 % of record span) - Disposable felt pen The recording width is 100mm and the length of the record paper is 16m. Thermotical electricity, measuring temperature resistor, DC current, DC voltage Communication function (RS-485)
Hybrid recorder HR-700 series-Part Number-HR-706, C5

HR-706, C5

Available upon quote There is no warning output, but the ALM indicator lights light. (If an alarm is required, an option is required.) The number of warnings is set for each channel with a maximum (2 points) and the lower limit (2 points). RS-485 (1200/2400/4800/9600/19200/38400bps) ± 0.2 % ± 1 digit or less Six points 100 ~ 240V AC 50/60Hz Measurement accuracy ± (0.3 % of record span) ・ Wired dot ・ Approximately 10 seconds (record cycle can be selected by setting) - The recording width is 100mm and the length of the record paper is 16m. Thermotical electricity, measuring temperature resistor, DC current, DC voltage Communication function (RS-485)
Hybrid recorder HR-700 series-Part Number-HR-701, Re1

HR-701, Re1

Available upon quote There is no warning output, but the ALM indicator lights light. (If an alarm is required, an option is required.) The number of warnings is set for each channel with a maximum (2 points) and the lower limit (2 points). RS-232C (1200/2400/4800/9600/19200/38400bps) ± 0.2 % ± 1 digit or less 1point 100 ~ 240V AC 50/60Hz Measurement accuracy ± (0.3 % of record span) - Disposable felt pen The recording width is 100mm and the length of the record paper is 16m. Thermotical electricity, measuring temperature resistor, DC current, DC voltage DI function
Hybrid recorder HR-700 series-Part Number-HR-702, Re1

HR-702, Re1

Available upon quote There is no warning output, but the ALM indicator lights light. (If an alarm is required, an option is required.) The number of warnings is set for each channel with a maximum (2 points) and the lower limit (2 points). RS-232C (1200/2400/4800/9600/19200/38400bps) ± 0.2 % ± 1 digit or less 2 points 100 ~ 240V AC 50/60Hz Measurement accuracy ± (0.3 % of record span) - Disposable felt pen The recording width is 100mm and the length of the record paper is 16m. Thermotical electricity, measuring temperature resistor, DC current, DC voltage DI function
Hybrid recorder HR-700 series-Part Number-HR-706, Re6

HR-706, Re6

Available upon quote There is no warning output, but the ALM indicator lights light. (If an alarm is required, an option is required.) The number of warnings is set for each channel with a maximum (2 points) and the lower limit (2 points). RS-232C (1200/2400/4800/9600/19200/38400bps) ± 0.2 % ± 1 digit or less Six points 100 ~ 240V AC 50/60Hz Measurement accuracy ± (0.3 % of record span) ・ Wired dot ・ Approximately 10 seconds (record cycle can be selected by setting) - The recording width is 100mm and the length of the record paper is 16m. Thermotical electricity, measuring temperature resistor, DC current, DC voltage DI function

Click on the part number for more information about each product

Customers who viewed this product also viewed

Other products of Shinko Technos Co., Ltd.


View more products of Shinko Technos Co., Ltd.

About Company Handling This Product

Shinko Technos Co., Ltd.

  • Japan
  • Since 1945
  • 185 employees

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.