Product
Digital indicator conductor AER-102-Ech (high concentration)Handling Company
Shinko Technos Co., Ltd.Categories
Usage Scenarios
Environment & Recycling Use / Pharmaceutical & Medical Use / Chemical Industry UseItems marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | Ambient temperature | Conductive proofreading | Conformity standard | Contact output | External dimensions | Instruction accuracy | Linearness | Peripheral humidity | Protective structure | Repetition | Self -diagnostic function | Serial Communication (Options: C5) Data Bit/Parity | Serial communication (Options: C5) | Serial communication (Options: C5) Certification format | Serial communication (Options: C5) Communication method | Serial communication (Options: C5) Communication protocol | Serial communication (Options: C5) Communication speed | Serial communication (Options: C5) Stop bit | Serial communication (Options: C5) Sync | Serial communication (Options: C5) error correction | Serial communication (option: C5) cable length | Serial communication (option: C5) communication line | Temperature compensation range | Temperature school regular | Transmission output 1-1 | Transmission output 1-2 | Transmission output 1-3 | mass | power supply | structure |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Aer-102-Ech, C5 |
Available upon quote | 0 to 50 ℃ | Conductive zero adjustment coefficient setting range: See item in the measurement range | ROHS command support |
・ Relay contact 1A ・ Control capacity: 3A 250V AC (resistance load), 1A 250V AC (induced load COSφ = 0.4) ・ Electrical life: 100,000 times ・ Control operation: P operation, ON/OFF operation |
W48XH96XD110mm case depth: 98.5mm (at panel mount) | Temperature: ± 1 ℃ |
・ Conductive: ± 0.5% of measurement range span ・ Salt conversion: ± 1% of measured range span ・ TDS conversion: ± 1.5% of measurement range span |
35 ~ 85%RH (but not condensation) | Over-pressure category Ⅱ, pollution 2 (IEC61010-1) |
・ Conductive: ± 0.5% of measurement range span ・ Salt conversion: ± 1% of measured range span ・ TDS conversion: ± 1.5% of measurement range span |
Motor the CPU with a watchdog timer and make the instrument into an initial state in the event of an abnormality. | 8 bits/none, 7 -bit/none, 8 -bit/even number, 7 -bit/even number, 8 -bit/odd, 7 -bit/odd number by key operation |
Perform the following operations from the external computer. ・ Read and set various set values ・ Reading of the conductive rate, temperature, and state ・ Change and adjust function ・ Reading and setting of user storage area |
ASCII, binary | Half double communication | Select Shinko Standard, Modbus ASCII, Modbus RTU by key operation | Select 9600, 19200, 38400 BPS by key operation | Select 1 bit and 2 bits by key operation | Toning synchronization | Command resend | 1.2 km (maximum) Cable resistance within 50Ω (end resistance: None or 120Ω or more on both sides) | EIA RS-485 compliant | 0.0 to 100.0 ° C | Calibration range: -10.0 ~ 10.0 ℃ | -Denstrual rate, temperature, and MV are converted to analog amount for each input sampling and output by current. (Factory shipping: Conductive) |
・ If the transmission output 1 maximum value and transmission output 1 are set to the same value, the transmission output 1 is 4 ma DC fixed. ・ The transmission output volume can be displayed. |
・ Dusive ability: 12000 ・ Current: 4 to 20mA DC (maximum load resistance 550Ω) ・ Output accuracy: within ± 0.3%of transmission output 1 span | Approximately 280g | 100 ~ 240 V AC 50/60 Hz tolerance fluctuation range: 85 ~ 264 v AC |
・ Control board embedded method (compatible panel thickness 1 ~ 8mm) ・ Case: flame -retardant resin color: black ・ Panel: Membrane sheet ・ Drip -proof / dustproof structure: front IP66 |
|
Aer-102-Ech, EVT3 |
Available upon quote | 0 to 50 ℃ | Conductive zero adjustment coefficient setting range: See item in the measurement range | ROHS command support |
・ Relay contact 1A ・ Control capacity: 3A 250V AC (resistance load), 1A 250V AC (induced load COSφ = 0.4) ・ Electrical life: 100,000 times ・ Control operation: P operation, ON/OFF operation |
W48XH96XD110mm case depth: 98.5mm (at panel mount) | Temperature: ± 1 ℃ | ・ Conductive: ± 0.5%of measuring range span ・ Salt conversion: Measurement range span ± 1%・ TDS conversion: measuring range span ± 1.5% | 35 ~ 85%RH (but not condensation) | Over-pressure category Ⅱ, pollution 2 (IEC61010-1) |
・ Conductive: ± 0.5% of measurement range span ・ Salt conversion: ± 1% of measured range span ・ TDS conversion: ± 1.5% of measurement range span |
Motor the CPU with a watchdog timer and make the instrument into an initial state in the event of an abnormality. | - | - | - | - | - | - | - | - | - | - | - | 0.0 to 100.0 ° C | Calibration range: -10.0 ~ 10.0 ℃ | -Denstrual rate, temperature, and MV are converted to analog amount for each input sampling and output by current. (Factory shipping: Conductive) |
・ If the transmission output 1 maximum value and transmission output 1 are set to the same value, the transmission output 1 is 4 ma DC fixed. ・ The transmission output volume can be displayed. |
・ Dusive ability: 12000 ・ Current: 4 to 20mA DC (maximum load resistance 550Ω) ・ Output accuracy: within ± 0.3%of transmission output 1 span | Approximately 280g | 100 ~ 240 V AC 50/60 Hz tolerance fluctuation range: 85 ~ 264 v AC |
・ Control board embedded method (compatible panel thickness 1 ~ 8mm) ・ Case: flame -retardant resin color: black ・ Panel: Membrane sheet ・ Drip -proof / dustproof structure: front IP66 |
|
Aer-102-Ech, TA2 |
Available upon quote | 0 to 50 ℃ | Conductive zero adjustment coefficient setting range: See item in the measurement range | ROHS command support |
・ Relay contact 1A ・ Control capacity: 3A 250V AC (resistance load), 1A 250V AC (induced load COSφ = 0.4) ・ Electrical life: 100,000 times ・ Control operation: P operation, ON/OFF operation |
W48XH96XD110mm case depth: 98.5mm (at panel mount) | Temperature: ± 1 ℃ |
・ Conductive: ± 0.5% of measurement range span ・ Salt conversion: ± 1% of measured range span ・ TDS conversion: ± 1.5% of measurement range span |
35 ~ 85%RH (but not condensation) | Over-pressure category Ⅱ, pollution 2 (IEC61010-1) |
・ Conductive: ± 0.5% of measurement range span ・ Salt conversion: ± 1% of measured range span ・ TDS conversion: ± 1.5% of measurement range span |
Motor the CPU with a watchdog timer and make the instrument into an initial state in the event of an abnormality. | - | - | - | - | - | - | - | - | - | - | - | 0.0 to 100.0 ° C | Calibration range: -10.0 ~ 10.0 ℃ | -Denstrual rate, temperature, and MV are converted to analog amount for each input sampling and output by current. (Factory shipping: Conductive) |
・ If the transmission output 1 maximum value and transmission output 1 are set to the same value, the transmission output 1 is 4 ma DC fixed. ・ The transmission output volume can be displayed. |
・ Dusive ability: 12000 ・ Current: 4 to 20mA DC (maximum load resistance 550Ω) ・ Output accuracy: within ± 0.3%of transmission output 1 span | Approximately 280g | 100 ~ 240 V AC 50/60 Hz tolerance fluctuation range: 85 ~ 264 v AC |
・ Control board embedded method (compatible panel thickness 1 ~ 8mm) ・ Case: flame -retardant resin color: black ・ Panel: Membrane sheet ・ Drip -proof / dustproof structure: front IP66 |
|
Aer-102-Ech1, C5 |
Available upon quote | 0 to 50 ℃ | Conductive zero adjustment coefficient setting range: See item in the measurement range | ROHS command support |
・ Relay contact 1A ・ Control capacity: 3A 250V AC (resistance load), 1A 250V AC (induced load COSφ = 0.4) ・ Electrical life: 100,000 times ・ Control operation: P operation, ON/OFF operation |
W48XH96XD110mm case depth: 98.5mm (at panel mount) | Temperature: ± 1 ℃ |
・ Conductive: ± 0.5% of measurement range span ・ Salt conversion: ± 1% of measured range span ・ TDS conversion: ± 1.5% of measurement range span |
35 ~ 85%RH (but not condensation) | Over-pressure category Ⅱ, pollution 2 (IEC61010-1) |
・ Conductive: ± 0.5% of measurement range span ・ Salt conversion: ± 1% of measured range span ・ TDS conversion: ± 1.5% of measurement range span |
Motor the CPU with a watchdog timer and make the instrument into an initial state in the event of an abnormality. | 8 bits/none, 7 -bit/none, 8 -bit/even number, 7 -bit/even number, 8 -bit/odd, 7 -bit/odd number by key operation |
Perform the following operations from the external computer. ・ Read and set various set values ・ Reading of the conductive rate, temperature, and state ・ Change and adjust function ・ Reading and setting of user storage area |
ASCII, binary | Half double communication | Select Shinko Standard, Modbus ASCII, Modbus RTU by key operation | Select 9600, 19200, 38400 BPS by key operation | Select 1 bit and 2 bits by key operation | Toning synchronization | Command resend | 1.2 km (maximum) Cable resistance within 50Ω (end resistance: None or 120Ω or more on both sides) | EIA RS-485 compliant | 0.0 to 100.0 ° C | Calibration range: -10.0 ~ 10.0 ℃ | -Denstrual rate, temperature, and MV are converted to analog amount for each input sampling and output by current. (Factory shipping: Conductive) |
・ If the transmission output 1 maximum value and transmission output 1 are set to the same value, the transmission output 1 is 4 ma DC fixed. ・ The transmission output volume can be displayed. |
・ Dusive ability: 12000 ・ Current: 4 to 20mA DC (maximum load resistance 550Ω) ・ Output accuracy: within ± 0.3%of transmission output 1 span | Approximately 280g | 24 V AC/DC 50/60 Hz Available range range: 20-28 v AC/DC |
・ Control board embedded method (compatible panel thickness 1 ~ 8mm) ・ Case: flame -retardant resin color: black ・ Panel: Membrane sheet ・ Drip -proof / dustproof structure: front IP66 |
|
AER-102-Ech1, EVT3 |
Available upon quote | 0 to 50 ℃ | Conductive zero adjustment coefficient setting range: See item in the measurement range | ROHS command support |
・ Relay contact 1A ・ Control capacity: 3A 250V AC (resistance load), 1A 250V AC (induced load COSφ = 0.4) ・ Electrical life: 100,000 times ・ Control operation: P operation, ON/OFF operation |
W48XH96XD110mm case depth: 98.5mm (at panel mount) | Temperature: ± 1 ℃ |
・ Conductive: ± 0.5% of measurement range span ・ Salt conversion: ± 1% of measured range span ・ TDS conversion: ± 1.5% of measurement range span |
35 ~ 85%RH (but not condensation) | Over-pressure category Ⅱ, pollution 2 (IEC61010-1) |
・ Conductive: ± 0.5% of measurement range span ・ Salt conversion: ± 1% of measured range span ・ TDS conversion: ± 1.5% of measurement range span |
Motor the CPU with a watchdog timer and make the instrument into an initial state in the event of an abnormality. | - | - | - | - | - | - | - | - | - | - | - | 0.0 to 100.0 ° C | Calibration range: -10.0 ~ 10.0 ℃ | -Denstrual rate, temperature, and MV are converted to analog amount for each input sampling and output by current. (Factory shipping: Conductive) |
・ If the transmission output 1 maximum value and transmission output 1 are set to the same value, the transmission output 1 is 4 ma DC fixed. ・ The transmission output volume can be displayed. |
・ Dusive ability: 12000 ・ Current: 4 to 20mA DC (maximum load resistance 550Ω) ・ Output accuracy: within ± 0.3%of transmission output 1 span | Approximately 280g | 24 V AC/DC 50/60 Hz Available range range: 20-28 v AC/DC |
・ Control board embedded method (compatible panel thickness 1 ~ 8mm) ・ Case: flame -retardant resin color: black ・ Panel: Membrane sheet ・ Drip -proof / dustproof structure: front IP66 |
|
AER-102-Ech1, TA2 |
Available upon quote | 0 to 50 ℃ | Conductive zero adjustment coefficient setting range: See item in the measurement range | ROHS command support |
・ Relay contact 1A ・ Control capacity: 3A 250V AC (resistance load), 1A 250V AC (induced load COSφ = 0.4) ・ Electrical life: 100,000 times ・ Control operation: P operation, ON/OFF operation |
W48XH96XD110mm case depth: 98.5mm (at panel mount) | Temperature: ± 1 ℃ |
・ Conductive: ± 0.5% of measurement range span ・ Salt conversion: ± 1% of measured range span ・ TDS conversion: ± 1.5% of measurement range span |
35 ~ 85%RH (but not condensation) | Over-pressure category Ⅱ, pollution 2 (IEC61010-1) |
・ Conductive: ± 0.5% of measurement range span ・ Salt conversion: ± 1% of measured range span ・ TDS conversion: ± 1.5% of measurement range span |
Motor the CPU with a watchdog timer and make the instrument into an initial state in the event of an abnormality. | - | - | - | - | - | - | - | - | - | - | - | 0.0 to 100.0 ° C | Calibration range: -10.0 ~ 10.0 ℃ | -Denstrual rate, temperature, and MV are converted to analog amount for each input sampling and output by current. (Factory shipping: Conductive) |
・ If the transmission output 1 maximum value and transmission output 1 are set to the same value, the transmission output 1 is 4 ma DC fixed. ・ The transmission output volume can be displayed. |
・ Dusive ability: 12000 ・ Current: 4 to 20mA DC (maximum load resistance 550Ω) ・ Output accuracy: within ± 0.3%of transmission output 1 span | Approximately 280g | 24 V AC/DC 50/60 Hz Available range range: 20-28 v AC/DC |
・ Control board embedded method (compatible panel thickness 1 ~ 8mm) ・ Case: flame -retardant resin color: black ・ Panel: Membrane sheet ・ Drip -proof / dustproof structure: front IP66 |
Click on the part number for more information about each product