About This Product

This is a digital indicator conductive rate meter that is installed on the control panel panel that supports various purposes, such as hydroponic cultivation, cooling tower (cooling tower) circulating water maintenance, salt measurement, and environmental measurement. ・ 48 × 96mm square, panel mount type ・ Drip -proof / dustproof structure IP66 compatible (front panel) ・ Compatible with power supply voltage 24 v AC/DC (specified by form name) ・ 2 points (standard), additional 2 points (optional) ・ Up to 4 points of contact compatible with proportional control ・ Various settings and calibration operations are possible via communication (RS-485) (optional) ・ 2 points of transmission output (optional)

  • Product

    Digital indicator conductor AER-102-Ech (high concentration)
  • Usage Scenarios

    Environment & Recycling Use / Pharmaceutical & Medical Use / Chemical Industry Use

Share this product


390+ people viewing

Last viewed: 10 hours ago


Free
Since our quotes are free, feel free to use our service.

No Phone Number Required
You won’t have to worry about receiving unnecessary calls.

6 Models of Digital indicator conductor AER-102-Ech (high concentration)

Items marked with have different values depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Ambient temperature Conductive proofreading Conformity standard Contact output External dimensions Instruction accuracy Linearness Peripheral humidity Protective structure Repetition Self -diagnostic function Serial Communication (Options: C5) Data Bit/Parity Serial communication (Options: C5) Serial communication (Options: C5) Certification format Serial communication (Options: C5) Communication method Serial communication (Options: C5) Communication protocol Serial communication (Options: C5) Communication speed Serial communication (Options: C5) Stop bit Serial communication (Options: C5) Sync Serial communication (Options: C5) error correction Serial communication (option: C5) cable length Serial communication (option: C5) communication line Temperature compensation range Temperature school regular Transmission output 1-1 Transmission output 1-2 Transmission output 1-3 mass power supply structure
Digital indicator conductor AER-102-Ech (high concentration)-Part Number-Aer-102-Ech, C5

Aer-102-Ech, C5

Available upon quote 0 to 50 ℃ Conductive zero adjustment coefficient setting range: See item in the measurement range ROHS command support ・ Relay contact 1A
・ Control capacity: 3A 250V AC (resistance load), 1A 250V AC (induced load COSφ = 0.4)
・ Electrical life: 100,000 times
・ Control operation: P operation, ON/OFF operation
W48XH96XD110mm case depth: 98.5mm (at panel mount) Temperature: ± 1 ℃ ・ Conductive: ± 0.5% of measurement range span
・ Salt conversion: ± 1% of measured range span
・ TDS conversion: ± 1.5% of measurement range span
35 ~ 85%RH (but not condensation) Over-pressure category Ⅱ, pollution 2 (IEC61010-1) ・ Conductive: ± 0.5% of measurement range span
・ Salt conversion: ± 1% of measured range span
・ TDS conversion: ± 1.5% of measurement range span
Motor the CPU with a watchdog timer and make the instrument into an initial state in the event of an abnormality. 8 bits/none, 7 -bit/none, 8 -bit/even number, 7 -bit/even number, 8 -bit/odd, 7 -bit/odd number by key operation Perform the following operations from the external computer.
・ Read and set various set values
・ Reading of the conductive rate, temperature, and state
・ Change and adjust function
・ Reading and setting of user storage area
ASCII, binary Half double communication Select Shinko Standard, Modbus ASCII, Modbus RTU by key operation Select 9600, 19200, 38400 BPS by key operation Select 1 bit and 2 bits by key operation Toning synchronization Command resend 1.2 km (maximum) Cable resistance within 50Ω (end resistance: None or 120Ω or more on both sides) EIA RS-485 compliant 0.0 to 100.0 ° C Calibration range: -10.0 ~ 10.0 ℃ -Denstrual rate, temperature, and MV are converted to analog amount for each input sampling and output by current. (Factory shipping: Conductive) ・ If the transmission output 1 maximum value and transmission output 1 are set to the same value, the transmission output 1 is 4 ma DC fixed.
・ The transmission output volume can be displayed.
・ Dusive ability: 12000 ・ Current: 4 to 20mA DC (maximum load resistance 550Ω) ・ Output accuracy: within ± 0.3%of transmission output 1 span Approximately 280g 100 ~ 240 V AC 50/60 Hz tolerance fluctuation range: 85 ~ 264 v AC ・ Control board embedded method (compatible panel thickness 1 ~ 8mm)
・ Case: flame -retardant resin color: black
・ Panel: Membrane sheet
・ Drip -proof / dustproof structure: front IP66
Digital indicator conductor AER-102-Ech (high concentration)-Part Number-Aer-102-Ech, EVT3

Aer-102-Ech, EVT3

Available upon quote 0 to 50 ℃ Conductive zero adjustment coefficient setting range: See item in the measurement range ROHS command support ・ Relay contact 1A
・ Control capacity: 3A 250V AC (resistance load), 1A 250V AC (induced load COSφ = 0.4)
・ Electrical life: 100,000 times
・ Control operation: P operation, ON/OFF operation
W48XH96XD110mm case depth: 98.5mm (at panel mount) Temperature: ± 1 ℃ ・ Conductive: ± 0.5%of measuring range span ・ Salt conversion: Measurement range span ± 1%・ TDS conversion: measuring range span ± 1.5% 35 ~ 85%RH (but not condensation) Over-pressure category Ⅱ, pollution 2 (IEC61010-1) ・ Conductive: ± 0.5% of measurement range span
・ Salt conversion: ± 1% of measured range span
・ TDS conversion: ± 1.5% of measurement range span
Motor the CPU with a watchdog timer and make the instrument into an initial state in the event of an abnormality. - - - - - - - - - - - 0.0 to 100.0 ° C Calibration range: -10.0 ~ 10.0 ℃ -Denstrual rate, temperature, and MV are converted to analog amount for each input sampling and output by current. (Factory shipping: Conductive) ・ If the transmission output 1 maximum value and transmission output 1 are set to the same value, the transmission output 1 is 4 ma DC fixed.
・ The transmission output volume can be displayed.
・ Dusive ability: 12000 ・ Current: 4 to 20mA DC (maximum load resistance 550Ω) ・ Output accuracy: within ± 0.3%of transmission output 1 span Approximately 280g 100 ~ 240 V AC 50/60 Hz tolerance fluctuation range: 85 ~ 264 v AC ・ Control board embedded method (compatible panel thickness 1 ~ 8mm)
・ Case: flame -retardant resin color: black
・ Panel: Membrane sheet
・ Drip -proof / dustproof structure: front IP66
Digital indicator conductor AER-102-Ech (high concentration)-Part Number-Aer-102-Ech, TA2

Aer-102-Ech, TA2

Available upon quote 0 to 50 ℃ Conductive zero adjustment coefficient setting range: See item in the measurement range ROHS command support ・ Relay contact 1A
・ Control capacity: 3A 250V AC (resistance load), 1A 250V AC (induced load COSφ = 0.4)
・ Electrical life: 100,000 times
・ Control operation: P operation, ON/OFF operation
W48XH96XD110mm case depth: 98.5mm (at panel mount) Temperature: ± 1 ℃ ・ Conductive: ± 0.5% of measurement range span
・ Salt conversion: ± 1% of measured range span
・ TDS conversion: ± 1.5% of measurement range span
35 ~ 85%RH (but not condensation) Over-pressure category Ⅱ, pollution 2 (IEC61010-1) ・ Conductive: ± 0.5% of measurement range span
・ Salt conversion: ± 1% of measured range span
・ TDS conversion: ± 1.5% of measurement range span
Motor the CPU with a watchdog timer and make the instrument into an initial state in the event of an abnormality. - - - - - - - - - - - 0.0 to 100.0 ° C Calibration range: -10.0 ~ 10.0 ℃ -Denstrual rate, temperature, and MV are converted to analog amount for each input sampling and output by current. (Factory shipping: Conductive) ・ If the transmission output 1 maximum value and transmission output 1 are set to the same value, the transmission output 1 is 4 ma DC fixed.
・ The transmission output volume can be displayed.
・ Dusive ability: 12000 ・ Current: 4 to 20mA DC (maximum load resistance 550Ω) ・ Output accuracy: within ± 0.3%of transmission output 1 span Approximately 280g 100 ~ 240 V AC 50/60 Hz tolerance fluctuation range: 85 ~ 264 v AC ・ Control board embedded method (compatible panel thickness 1 ~ 8mm)
・ Case: flame -retardant resin color: black
・ Panel: Membrane sheet
・ Drip -proof / dustproof structure: front IP66
Digital indicator conductor AER-102-Ech (high concentration)-Part Number-Aer-102-Ech1, C5

Aer-102-Ech1, C5

Available upon quote 0 to 50 ℃ Conductive zero adjustment coefficient setting range: See item in the measurement range ROHS command support ・ Relay contact 1A
・ Control capacity: 3A 250V AC (resistance load), 1A 250V AC (induced load COSφ = 0.4)
・ Electrical life: 100,000 times
・ Control operation: P operation, ON/OFF operation
W48XH96XD110mm case depth: 98.5mm (at panel mount) Temperature: ± 1 ℃ ・ Conductive: ± 0.5% of measurement range span
・ Salt conversion: ± 1% of measured range span
・ TDS conversion: ± 1.5% of measurement range span
35 ~ 85%RH (but not condensation) Over-pressure category Ⅱ, pollution 2 (IEC61010-1) ・ Conductive: ± 0.5% of measurement range span
・ Salt conversion: ± 1% of measured range span
・ TDS conversion: ± 1.5% of measurement range span
Motor the CPU with a watchdog timer and make the instrument into an initial state in the event of an abnormality. 8 bits/none, 7 -bit/none, 8 -bit/even number, 7 -bit/even number, 8 -bit/odd, 7 -bit/odd number by key operation Perform the following operations from the external computer.
・ Read and set various set values
・ Reading of the conductive rate, temperature, and state
・ Change and adjust function
・ Reading and setting of user storage area
ASCII, binary Half double communication Select Shinko Standard, Modbus ASCII, Modbus RTU by key operation Select 9600, 19200, 38400 BPS by key operation Select 1 bit and 2 bits by key operation Toning synchronization Command resend 1.2 km (maximum) Cable resistance within 50Ω (end resistance: None or 120Ω or more on both sides) EIA RS-485 compliant 0.0 to 100.0 ° C Calibration range: -10.0 ~ 10.0 ℃ -Denstrual rate, temperature, and MV are converted to analog amount for each input sampling and output by current. (Factory shipping: Conductive) ・ If the transmission output 1 maximum value and transmission output 1 are set to the same value, the transmission output 1 is 4 ma DC fixed.
・ The transmission output volume can be displayed.
・ Dusive ability: 12000 ・ Current: 4 to 20mA DC (maximum load resistance 550Ω) ・ Output accuracy: within ± 0.3%of transmission output 1 span Approximately 280g 24 V AC/DC 50/60 Hz Available range range: 20-28 v AC/DC ・ Control board embedded method (compatible panel thickness 1 ~ 8mm)
・ Case: flame -retardant resin color: black
・ Panel: Membrane sheet
・ Drip -proof / dustproof structure: front IP66
Digital indicator conductor AER-102-Ech (high concentration)-Part Number-AER-102-Ech1, EVT3

AER-102-Ech1, EVT3

Available upon quote 0 to 50 ℃ Conductive zero adjustment coefficient setting range: See item in the measurement range ROHS command support ・ Relay contact 1A
・ Control capacity: 3A 250V AC (resistance load), 1A 250V AC (induced load COSφ = 0.4)
・ Electrical life: 100,000 times
・ Control operation: P operation, ON/OFF operation
W48XH96XD110mm case depth: 98.5mm (at panel mount) Temperature: ± 1 ℃ ・ Conductive: ± 0.5% of measurement range span
・ Salt conversion: ± 1% of measured range span
・ TDS conversion: ± 1.5% of measurement range span
35 ~ 85%RH (but not condensation) Over-pressure category Ⅱ, pollution 2 (IEC61010-1) ・ Conductive: ± 0.5% of measurement range span
・ Salt conversion: ± 1% of measured range span
・ TDS conversion: ± 1.5% of measurement range span
Motor the CPU with a watchdog timer and make the instrument into an initial state in the event of an abnormality. - - - - - - - - - - - 0.0 to 100.0 ° C Calibration range: -10.0 ~ 10.0 ℃ -Denstrual rate, temperature, and MV are converted to analog amount for each input sampling and output by current. (Factory shipping: Conductive) ・ If the transmission output 1 maximum value and transmission output 1 are set to the same value, the transmission output 1 is 4 ma DC fixed.
・ The transmission output volume can be displayed.
・ Dusive ability: 12000 ・ Current: 4 to 20mA DC (maximum load resistance 550Ω) ・ Output accuracy: within ± 0.3%of transmission output 1 span Approximately 280g 24 V AC/DC 50/60 Hz Available range range: 20-28 v AC/DC ・ Control board embedded method (compatible panel thickness 1 ~ 8mm)
・ Case: flame -retardant resin color: black
・ Panel: Membrane sheet
・ Drip -proof / dustproof structure: front IP66
Digital indicator conductor AER-102-Ech (high concentration)-Part Number-AER-102-Ech1, TA2

AER-102-Ech1, TA2

Available upon quote 0 to 50 ℃ Conductive zero adjustment coefficient setting range: See item in the measurement range ROHS command support ・ Relay contact 1A
・ Control capacity: 3A 250V AC (resistance load), 1A 250V AC (induced load COSφ = 0.4)
・ Electrical life: 100,000 times
・ Control operation: P operation, ON/OFF operation
W48XH96XD110mm case depth: 98.5mm (at panel mount) Temperature: ± 1 ℃ ・ Conductive: ± 0.5% of measurement range span
・ Salt conversion: ± 1% of measured range span
・ TDS conversion: ± 1.5% of measurement range span
35 ~ 85%RH (but not condensation) Over-pressure category Ⅱ, pollution 2 (IEC61010-1) ・ Conductive: ± 0.5% of measurement range span
・ Salt conversion: ± 1% of measured range span
・ TDS conversion: ± 1.5% of measurement range span
Motor the CPU with a watchdog timer and make the instrument into an initial state in the event of an abnormality. - - - - - - - - - - - 0.0 to 100.0 ° C Calibration range: -10.0 ~ 10.0 ℃ -Denstrual rate, temperature, and MV are converted to analog amount for each input sampling and output by current. (Factory shipping: Conductive) ・ If the transmission output 1 maximum value and transmission output 1 are set to the same value, the transmission output 1 is 4 ma DC fixed.
・ The transmission output volume can be displayed.
・ Dusive ability: 12000 ・ Current: 4 to 20mA DC (maximum load resistance 550Ω) ・ Output accuracy: within ± 0.3%of transmission output 1 span Approximately 280g 24 V AC/DC 50/60 Hz Available range range: 20-28 v AC/DC ・ Control board embedded method (compatible panel thickness 1 ~ 8mm)
・ Case: flame -retardant resin color: black
・ Panel: Membrane sheet
・ Drip -proof / dustproof structure: front IP66

Click on the part number for more information about each product

Customers who viewed this product also viewed

Other products of Shinko Technos Co., Ltd.


View more products of Shinko Technos Co., Ltd.

About Company Handling This Product

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree