It is a digital temperature instruction adjustment meter that can be set like an analog with a large knob. You can easily set it even if the button is difficult to press with gloves. ・ 3 digits LED display ・ Large knob ■ Analog settings with potenthameter Inherit the operability of the ACN-100 series. You can easily set and change with analog settings with potenthaometer. ■ Auto reset function ACN-220 (PD operation) has an auto reset function. ■ Control operation can be changed with the switch Control operation: PD operation and ON/OFF operation can be selected by dip switch. ■ Warning output With a deviation setting for SV (excluding absolute values ​​warning), if the PV exceeds that range, the alarm output becomes ON or OFF (up lower or lower range warning). If the alarm function is specified, there is no operation, there is no operation, the upper limit warning, waiting on the upper limit warning, the lower limit warning, the upper and lower limit warnings, the waiting upwards, the lower limit warning, the absolute price maximum warning, the absolute lower limit warning. You can select one from the inside with a dip switch. * There are other model numbers

  • Product

    Digital temperature instruction adjustment ACN-200




*Please note that we may not be able to accommodate sample requests.

10 Models of Digital temperature instruction adjustment ACN-200

Items marked with have different values ​​depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Attached function Control action Control operation ON/OFF Operation Control operation differentiation time (d) Control operation proportional belt (p) Control operation proportional cycle Control output non -contact voltage (for SSR drive) Control output relay contact 1C External dimensions Input measurement temperature resistor Input sampling cycle Input thermoelectric dating Instruction Organization Operation Light Instruction Organization PV Display Current value display) Instruction accuracy Material Mounting method Potentiometer Power-supply voltage Rated scale range thermal electric vs. EJ input (decomposed ability 1 ℃) Rated scale range thermal electric vs. EK input (decomposed ability 1 ℃) Rated scale scale Temperature resistant RPT100 input (decomposed ability 1 ℃) SV settings Setting accuracy Tolerance fluctuation range Warning output movement loves Warning output operation Warning output setting accuracy color function key
Digital temperature instruction adjustment ACN-200-Part Number-ACN-210-R/E

ACN-210-R/E

Available upon quote Power outage countermeasures, self -diagnosis, automatic cold contact temperature compensation, burnout, input abnormality, warm -up display ON/OFF operation (dip switch No.1: ON) 0.6% of each input span - - - - ・ Control capacity: 5A 250V AC (resistance load), 2A 250V AC (induced load COSφ = 0.4)
・ Electrical life: 100,000 times
96 x 96 x 120mm (horizontal x vertical x depth) - 250ms ・ K, J
・ External resistance 100Ω or less
ON indicator (green): Control output ON turn/OFF display light (red): Control output OFF ・ 7 -segment red LED display 3 digits
・ Character dimensions 10.4 x 4.9mm (height x width)
Within 0.5%1 digit of each input span Case: Polycarbonate resin Control board embedded system SV setting scale length 121mm (angle 240 degrees) 100 ~ 240V AC 50/60Hz 0 ~ 400 ℃ Settings 1 scale: 5 ℃ 0 ~ 400 ℃ Settings 1 scale: 5 ℃ - Analog settings with potenthameter ± 1.0% of each input span 85 ~ 264V AC - - - Dark gray RESET key Execute auto-reset
Digital temperature instruction adjustment ACN-200-Part Number-ACN-210-R/R

ACN-210-R/R

Available upon quote Power outage countermeasures, self -diagnosis, automatic cold contact temperature compensation, burnout, input abnormality, warm -up display ON/OFF operation (dip switch No.1: ON) 0.6% of each input span - - - - ・ Control capacity: 5A 250V AC (resistance load), 2A 250V AC (induced load COSφ = 0.4)
・ Electrical life: 100,000 times
96 x 96 x 120mm (horizontal x vertical x depth) ・ PT100 3 conductor type
・ Removable value per tolerable input wire resistance 10Ω or less
250ms - ON indicator (green): Control output ON turn/OFF display light (red): Control output OFF ・ 7 -segment red LED display 3 digits
・ Character dimensions 10.4 x 4.9mm (height x width)
Within 0.5%1 digit of each input span Case: Polycarbonate resin Control board embedded system SV setting scale length 121mm (angle 240 degrees) 100 ~ 240V AC 50/60Hz - - 0 ~ 100 ℃ Setting value 1 scale: 1 ℃ Analog settings with potenthameter ± 1.0% of each input span 85 ~ 264V AC - - - Dark gray -
Digital temperature instruction adjustment ACN-200-Part Number-ACN-210-S/E

ACN-210-S/E

Available upon quote Power outage countermeasures, self -diagnosis, automatic cold contact temperature compensation, burnout, input abnormality, warm -up display ON/OFF operation (dip switch No.1: ON) 0.6% of each input span - - - 12V DC15% up to 40mA DC (with short circuit protection circuit) - 96 x 96 x 120mm (horizontal x vertical x depth) - 250ms ・ K, J
・ External resistance 100Ω or less
ON indicator (green): Control output ON turn/OFF display light (red): Control output OFF ・ 7 -segment red LED display 3 digits
・ Character dimensions 10.4 x 4.9mm (height x width)
Within 0.5%1 digit of each input span Case: Polycarbonate resin Control board embedded system SV setting scale length 121mm (angle 240 degrees) 100 ~ 240V AC 50/60Hz 0 ~ 400 ℃ Settings 1 scale: 5 ℃ 0 ~ 400 ℃ Settings 1 scale: 5 ℃ - Analog settings with potenthameter ± 1.0% of each input span 85 ~ 264V AC - - - Dark gray -
Digital temperature instruction adjustment ACN-200-Part Number-ACN-210-S/R

ACN-210-S/R

Available upon quote Power outage countermeasures, self -diagnosis, automatic cold contact temperature compensation, burnout, input abnormality, warm -up display ON/OFF operation (dip switch No.1: ON) 0.6% of each input span - - - 12V DC15% up to 40mA DC (with short circuit protection circuit) - 96 x 96 x 120mm (horizontal x vertical x depth) ・ PT100 3 conductor type
・ Removable value per tolerable input wire resistance 10Ω or less
250ms - ON indicator (green): Control output ON turn/OFF display light (red): Control output OFF ・ 7 -segment red LED display 3 digits
・ Character dimensions 10.4 x 4.9mm (height x width)
Within 0.5%1 digit of each input span Case: Polycarbonate resin Control board embedded system SV setting scale length 121mm (angle 240 degrees) 100 ~ 240V AC 50/60Hz - - 0 ~ 100 ℃ Setting value 1 scale: 1 ℃ Analog settings with potenthameter ± 1.0% of each input span 85 ~ 264V AC - - - Dark gray -
Digital temperature instruction adjustment ACN-200-Part Number-ACN-211-R/E

ACN-211-R/E

Available upon quote Power outage countermeasures, self -diagnosis, automatic cold contact temperature compensation, burnout, input abnormality, warm -up display ON/OFF operation (dip switch No.1: ON) 0.6% of each input span - - - - ・ Control capacity: 5A 250V AC (resistance load), 2A 250V AC (induced load COSφ = 0.4)
・ Electrical life: 100,000 times
96 x 96 x 120mm (horizontal x vertical x depth) - 250ms ・ K, J
・ External resistance 100Ω or less
ON indicator (green): Control output ON turn/OFF display light (red): Control output OFF ・ 7 -segment red LED display 3 digits
・ Character dimensions 10.4 x 4.9mm (height x width)
Within 0.5%1 digit of each input span Case: Polycarbonate resin Control board embedded system SV setting scale length 121mm (angle 240 degrees) 100 ~ 240V AC 50/60Hz 0 ~ 400 ℃ Settings 1 scale: 5 ℃ 0 ~ 400 ℃ Settings 1 scale: 5 ℃ - Analog settings with potenthameter ± 1.0% of each input span 85 ~ 264V AC 1 ° C ON/OFF operation Same as control performance setting accuracy Dark gray -
Digital temperature instruction adjustment ACN-200-Part Number-ACN-211-R/R

ACN-211-R/R

Available upon quote Power outage countermeasures, self -diagnosis, automatic cold contact temperature compensation, burnout, input abnormality, warm -up display ON/OFF operation (dip switch No.1: ON) 0.6% of each input span - - - - ・ Control capacity: 5A 250V AC (resistance load), 2A 250V AC (induced load COSφ = 0.4)
・ Electrical life: 100,000 times
96 x 96 x 120mm (horizontal x vertical x depth) ・ PT100 3 conductor type
・ Removable value per tolerable input wire resistance 10Ω or less
250ms - ON indicator (green): Control output ON turn/OFF display light (red): Control output OFF ・ 7 -segment red LED display 3 digits ・ Character dimensions 10.4 x 4.9mm (height x width) Within 0.5%1 digit of each input span Case: Polycarbonate resin Control board embedded system SV setting scale length 121mm (angle 240 degrees) 100 ~ 240V AC 50/60Hz - - 0 ~ 100 ℃ Setting value 1 scale: 1 ℃ Analog settings with potenthameter ± 1.0% of each input span 85 ~ 264V AC 1 ° C ON/OFF operation Same as control performance setting accuracy Dark gray -
Digital temperature instruction adjustment ACN-200-Part Number-ACN-211-S/E

ACN-211-S/E

Available upon quote Power outage countermeasures, self -diagnosis, automatic cold contact temperature compensation, burnout, input abnormality, warm -up display ON/OFF operation (dip switch No.1: ON) 0.6% of each input span - - - 12V DC15% up to 40mA DC (with short circuit protection circuit) - 96 x 96 x 120mm (horizontal x vertical x depth) - 250ms ・ K, J
・ External resistance 100Ω or less
ON indicator (green): Control output ON turn/OFF display light (red): Control output OFF ・ 7 -segment red LED display 3 digits
・ Character dimensions 10.4 x 4.9mm (height x width)
Within 0.5%1 digit of each input span Case: Polycarbonate resin Control board embedded system SV setting scale length 121mm (angle 240 degrees) 100 ~ 240V AC 50/60Hz 0 ~ 400 ℃ Settings 1 scale: 5 ℃ 0 ~ 400 ℃ Settings 1 scale: 5 ℃ - Analog settings with potenthameter ± 1.0% of each input span 85 ~ 264V AC 1 ° C ON/OFF operation Same as control performance setting accuracy Dark gray -
Digital temperature instruction adjustment ACN-200-Part Number-ACN-211-S/R

ACN-211-S/R

Available upon quote Power outage countermeasures, self -diagnosis, automatic cold contact temperature compensation, burnout, input abnormality, warm -up display ON/OFF operation (dip switch No.1: ON) 0.6% of each input span - - - 12V DC15% up to 40mA DC (with short circuit protection circuit) - 96 x 96 x 120mm (horizontal x vertical x depth) ・ PT100 3 conductor type
・ Removable value per tolerable input wire resistance 10Ω or less
250ms - ON indicator (green): Control output ON turn/OFF display light (red): Control output OFF ・ 7 -segment red LED display 3 digits
・ Character dimensions 10.4 x 4.9mm (height x width)
Within 0.5%1 digit of each input span Case: Polycarbonate resin Control board embedded system SV setting scale length 121mm (angle 240 degrees) 100 ~ 240V AC 50/60Hz - - 0 ~ 100 ℃ Setting value 1 scale: 1 ℃ Analog settings with potenthameter ± 1.0% of each input span 85 ~ 264V AC 1 ° C ON/OFF operation Same as control performance setting accuracy Dark gray -
Digital temperature instruction adjustment ACN-200-Part Number-ACN-221-R/E

ACN-221-R/E

Available upon quote Power outage countermeasures, self -diagnosis, automatic cold contact temperature compensation, burnout, input abnormality, warm -up display PD operation (dip switch No.1: OFF) - 50 seconds 2.5% of each input span Relay contact output: 30 seconds - ・ Control capacity: 5A 250V AC (resistance load), 2A 250V AC (induced load COSφ = 0.4)
・ Electrical life: 100,000 times
96 x 96 x 120mm (horizontal x vertical x depth) - 250ms ・ K, J
・ External resistance 100Ω or less
ON indicator (green): Control output ON turn/OFF display light (red): Control output OFF ・ 7 -segment red LED display 3 digits
・ Character dimensions 10.4 x 4.9mm (height x width)
Within 0.5%1 digit of each input span Case: Polycarbonate resin Control board embedded system SV setting scale length 121mm (angle 240 degrees) 100 ~ 240V AC 50/60Hz 0 ~ 400 ℃ Settings 1 scale: 5 ℃ 0 ~ 400 ℃ Settings 1 scale: 5 ℃ - Analog settings with potenthameter ± 1.0% of each input span 85 ~ 264V AC 1 ° C ON/OFF operation Same as control performance setting accuracy Dark gray Execute the reset key auto reset
Digital temperature instruction adjustment ACN-200-Part Number-ACN-221-R/R

ACN-221-R/R

Available upon quote Power outage countermeasures, self -diagnosis, automatic cold contact temperature compensation, burnout, input abnormality, warm -up display PD operation (dip switch No.1: OFF) - 50 seconds 2.5% of each input span Relay contact output: 30 seconds - ・ Control capacity: 5A 250V AC (resistance load), 2A 250V AC (induced load COSφ = 0.4)
・ Electrical life: 100,000 times
96 x 96 x 120mm (horizontal x vertical x depth) ・ PT100 3 conductor type
・ Removable value per tolerable input wire resistance 10Ω or less
250ms - ON indicator (green): Control output ON turn/OFF display light (red): Control output OFF ・ 7 -segment red LED display 3 digits
・ Character dimensions 10.4 x 4.9mm (height x width)
Within 0.5%1 digit of each input span Case: Polycarbonate resin Control board embedded system SV setting scale length 121mm (angle 240 degrees) 100 ~ 240V AC 50/60Hz - - 0 ~ 100 ℃ Setting value 1 scale: 1 ℃ Analog settings with potenthameter ± 1.0% of each input span 85 ~ 264V AC 1 ° C ON/OFF operation Same as control performance setting accuracy Dark gray Execute the reset key auto reset

Click on the part number for more information about each product

Customers who viewed this product also viewed

Other products of Shinko Technos Co., Ltd.


View more products of Shinko Technos Co., Ltd.

About Company Handling This Product

Shinko Technos Co., Ltd.

  • Japan
  • Since 1945
  • 185 employees

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree