USB memory data history collection device Lul1-Lul1
USB memory data history collection device Lul1-Shinko Technos Co., Ltd.

USB memory data history collection device Lul1
Shinko Technos Co., Ltd.


About This Product

Three types of logging mode can be selected ■ Overview of this instrument In this equipment, data is imported from the connected device (up to 16 units), and the data is written on a USB memory that is equipped with console software. There are three types of data collection methods: ・ Host mode This instrument is a host device, and is a mode in which the command is sent and the response data from the connection device is set as logging data as a logging data, which is set in advance with console software to the connected device (slave unit). ・ Monitor mode Connect the instrument to the serial communication line between the host device and the device (a slave unit) that performs a serial communication, receive the communication data flowing on the line, and have a transmission and receiving command that matches the communication command conditions set in the console software. This is a mode that takes out data and saves files as logging data. ・ Analyzer mode This mode is connected to the serial communication line between the host device and the serial communication device (slave unit), receives all communication data flowing on the line, and saves files as logging data.

  • Product

    USB memory data history collection device Lul1




*Please note that we may not be able to accommodate sample requests.

1 Models of USB memory data history collection device Lul1

Product Image Part Number Price (excluding tax) Clock blackout compensation Clock error Clock time display Equipment for logging function External storage device Other 1 External storage device Others 2 External storage device Others 3 External storage device USB memory recognition operation 1 External storage device USB memory recognition operation 2 External storage device format External storage device media External storage device writing method Logging function logging 1 Logging function logging 2 Logging function logging cycle Logging function logging item Serial communication (between equipment and equipment) Reception contents Serial communication (between equipment and equipment) communication circuit Serial communication (between equipment and equipment) communication method Serial communication (between equipment and equipment) communication protocol Serial communication (between equipment and equipment) communication speed Serial communication (between equipment and equipment) data configuration Serial communication (between this device-PC) communication circuit Serial communication (between this device-PC) communication speed Serial communication (between this instrument-PC) communication method Serial communication (between this instrument-PC) communication protocol Synchronous method (between equipment and equipment) synchronous method Synchronous method (between this instrument-PC) synchronous method Time setting accuracy display
USB memory data history collection device Lul1-Part Number-Lul1

Lul1

Available upon quote ・ Back up with lithium battery
・ Light of 10 years of lithium battery (when surrounding temperature is 20 ° C)
± 60 seconds/month (when the surrounding temperature is 25 ° C) 24 -hour time method Shinko Protocol, Modbus protocol (ASCII or RTU) device In the host mode and monitor mode, when the logging data reaches 65,000 lines, close the file and save the data in a new file. In the analyzer mode, the Shinto Port protocol and the Modbus RTU protocol will close the files and save the data to a new file when the logging data is reached and the Modbus ASCII protocol reaches 65,000 lines. However, when the date changes, close the logging file and save the data in a new file. USB memory recognition operation is performed when the USB memory is inserted. Check the free space of the USB memory, create a temporary CSV file and recognize the file. Delete the created file and end the USB memory recognition operation. This USB memory recognition operation may require several tens of seconds during the recognition operation by the inserted USB memory. USB memory recognition cannot be started during the operation operation. Compatible with FAT16 and FAT32. USB memory (up to 32GB) New writing (Open new files and save data each time you start data roaging) Always store and save data from the connected device, and write data stored in the USB memory for each logging cycle. If the device cannot be communicated and the data cannot be imported, the writing data will be blank. If all items have no selection, they cannot start logging. According to the setting value. Depending on the inserted USB memory, it may not be possible to log in a short logging cycle. Items specified by the logging date and time and console software (for 1 item 1 data, up to 16 items (up to 16 data). If 1 item is specified, the maximum number of items decreases.) Logging mode selection contents and data specified by console software RS-485 compliant Half double communication Shinko Protocol, Modbus ASCII, Modbus RTU 9600 BPS, 19200 BPS, 38400 BPS ・ Start bit: 1 bit
・ Data bit: 7 bit, 8 bit
・ Parity Bit: No Parity, even parity, odd parity
・ Stop bit: 1 bit, 2 bit
RS-485 compliant 9600 BPS Half double communication Shinko Protocol Toning synchronization Toning synchronization Within ± 0.5 % 1 second ・ Logging display: Red LED 4 digit character Dimensions 10 × 4.6mm (height x width)
・ Multi -display: Red LED 4 digit characters 10 × 4.6mm (height x width)

Customers who viewed this product also viewed

Other products of Shinko Technos Co., Ltd.


View more products of Shinko Technos Co., Ltd.