Product
Digital instruction adjustment meter JCM-33A series (72mm square)Handling Company
Shinko Technos Co., Ltd.Items marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | Ambient temperature | Attached function | Control action | Control output | DC current, DC voltage accuracy | Mounting method | Peripheral humidity | Power-supply voltage | Sampling cycle | Temperature resistance accuracy | Thermotical accuracy 1 | Thermotical accuracy 2 | Thermotical accuracy 3 | Warning 1 (A1) 1 | Warning 1 (A1) 2 | input | mass | option | power consumption |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
JCM-33A-R/M |
Available upon quote | 0 to 50 ℃ | Sensor correction, set value lock, power outage countermeasure, self -diagnosis, automatic cold contact temperature compensation (thermoelectric dating only), sensor disconnection warning, input abnormality | Auto tuning PID, PI, PD, P, ON/OFF | Relay contact | ・ Within ± 0.2%± 1 digit of each input span | Mounting bracket: Thickness of screw type, mounting panel: within 1 to 15mm | 35 ~ 85%RH (not condensation) | 100 ~ 240V AC 50/60Hz | 250ms | ・ Within ± 0.1%± 1 digit or within ± 1 ° C (2 ° F) of each input span | ・ Within ± 0.2%± 1 digit or within ± 2 ° C (4 ° F) of each input span | ・ However, the range of 0 to 200 ° C (32 to 392 ° F) by R or S input is within ± 6 ° C (12 ° F) ・ The range of 0 to 300 ° C (32 to 572 ° F) by B input. Out of accuracy guarantee range | ・ K, J, E, T, N input is less than 0 ° C (32 ° F) within ± 0.4%± 1 digit or ± 4 ° C (8 ° F) of the input span. | ・ No warning, maximum operation, lower limit operation, waiting motion limit operation, waiting lower limit operation, up and down limited operation, up and lower range operation, upwards and lower and lower operations | ・ Absolute price maximum operation, absolute price lower operation, excitation/non -magnetic selection can be selected by key operation. | ・ Thermal electricity vs. K, J, R, S, B, E, T, N, PL-I, C (W/Re5-26) ・ Temperature resistance body: PT100, JPT100 ・ DC current: 4 ~ 20mA DC, 0 ~ 20mA DC / DC voltage: 0 ~ 1V DC, 0 ~ 10V DC, 1 ~ 5V DC, 0 ~ 5V DC | Approximately 300g | - | Approximately 8VA | |
JCM-33A-S/M |
Available upon quote | 0 to 50 ℃ | Sensor correction, set value lock, power outage countermeasure, self -diagnosis, automatic cold contact temperature compensation (thermoelectric dating only), sensor disconnection warning, input abnormality | Auto tuning PID, PI, PD, P, ON/OFF | Non -contact voltage | ・ Within ± 0.2%± 1 digit of each input span | Mounting bracket: Thickness of screw type, mounting panel: within 1 to 15mm | 35 ~ 85%RH (not condensation) | 100 ~ 240V AC 50/60Hz | 250ms | ・ Within ± 0.1%± 1 digit or within ± 1 ° C (2 ° F) of each input span | ・ Within ± 0.2%± 1 digit or within ± 2 ° C (4 ° F) of each input span | ・ However, the range of 0 to 200 ° C (32 to 392 ° F) by R or S input is within ± 6 ° C (12 ° F) ・ The range of 0 to 300 ° C (32 to 572 ° F) by B input. Out of accuracy guarantee range | ・ K, J, E, T, N input is less than 0 ° C (32 ° F) within ± 0.4%± 1 digit or ± 4 ° C (8 ° F) of the input span. | ・ No warning, maximum operation, lower limit operation, waiting motion limit operation, waiting lower limit operation, up and down limited operation, up and lower range operation, upwards and lower and lower operations | ・ Absolute price maximum operation, absolute price lower operation, excitation/non -magnetic selection can be selected by key operation. | ・ Thermal electricity vs. K, J, R, S, B, E, T, N, PL-I, C (W/Re5-26) ・ Temperature resistance body: PT100, JPT100 ・ DC current: 4 ~ 20mA DC, 0 ~ 20mA DC / DC voltage: 0 ~ 1V DC, 0 ~ 10V DC, 1 ~ 5V DC, 0 ~ 5V DC | Approximately 300g | - | Approximately 8VA | |
JCM-33A-A/M |
Available upon quote | 0 to 50 ℃ | Sensor correction, set value lock, power outage countermeasure, self -diagnosis, automatic cold contact temperature compensation (thermoelectric dating only), sensor disconnection warning, input abnormality | Auto tuning PID, PI, PD, P, ON/OFF | DC current | ・ Within ± 0.2%± 1 digit of each input span | Mounting bracket: Thickness of screw type, mounting panel: within 1 to 15mm | 35 ~ 85%RH (not condensation) | 100 ~ 240V AC 50/60Hz | 250ms | ・ Within ± 0.1%± 1 digit or within ± 1 ° C (2 ° F) of each input span | ・ Within ± 0.2%± 1 digit or within ± 2 ° C (4 ° F) of each input span | ・ However, the range of 0 to 200 ° C (32 to 392 ° F) by R or S input is within ± 6 ° C (12 ° F) ・ The range of 0 to 300 ° C (32 to 572 ° F) by B input. Out of accuracy guarantee range | ・ K, J, E, T, N input is less than 0 ° C (32 ° F) within ± 0.4%± 1 digit or ± 4 ° C (8 ° F) of the input span. | ・ No warning, maximum operation, lower limit operation, waiting motion limit operation, waiting lower limit operation, up and down limited operation, up and lower range operation, upwards and lower and lower operations | ・ Absolute price maximum operation, absolute price lower operation, excitation/non -magnetic selection can be selected by key operation. | ・ Thermal electricity vs. K, J, R, S, B, E, T, N, PL-I, C (W/Re5-26) ・ Temperature resistance body: PT100, JPT100 ・ DC current: 4 ~ 20mA DC, 0 ~ 20mA DC / DC voltage: 0 ~ 1V DC, 0 ~ 10V DC, 1 ~ 5V DC, 0 ~ 5V DC | Approximately 300g | - | Approximately 8VA | |
JCM-33A-R/M 1, A2 |
Available upon quote | 0 to 50 ℃ | Sensor correction, set value lock, power outage countermeasure, self -diagnosis, automatic cold contact temperature compensation (thermoelectric dating only), sensor disconnection warning, input abnormality | Auto tuning PID, PI, PD, P, ON/OFF | Relay contact | ・ Within ± 0.2%± 1 digit of each input span | Mounting bracket: Thickness of screw type, mounting panel: within 1 to 15mm | 35 ~ 85%RH (not condensation) | 24V AC/DC 50/60Hz | 250ms | ・ Within ± 0.1%± 1 digit or within ± 1 ° C (2 ° F) of each input span | ・ Within ± 0.2%± 1 digit or within ± 2 ° C (4 ° F) of each input span | ・ However, the range of 0 to 200 ° C (32 to 392 ° F) by R or S input is within ± 6 ° C (12 ° F) ・ The range of 0 to 300 ° C (32 to 572 ° F) by B input. Out of accuracy guarantee range | ・ K, J, E, T, N input is less than 0 ° C (32 ° F) within ± 0.4%± 1 digit or ± 4 ° C (8 ° F) of the input span. | ・ No warning, maximum operation, lower limit operation, waiting motion limit operation, waiting lower limit operation, up and down limited operation, up and lower range operation, upwards and lower and lower operations | ・ Absolute price maximum operation, absolute price lower operation, excitation/non -magnetic selection can be selected by key operation. | ・ Thermal electricity vs. K, J, R, S, B, E, T, N, PL-I, C (W/Re5-26) ・ Temperature resistance body: PT100, JPT100 ・ DC current: 4 ~ 20mA DC, 0 ~ 20mA DC / DC voltage: 0 ~ 1V DC, 0 ~ 10V DC, 1 ~ 5V DC, 0 ~ 5V DC | Approximately 300g | Alarm 2 | Approximately 8VA | |
JCM-33A-R/M, A2, LA |
Available upon quote | 0 to 50 ℃ | Sensor correction, set value lock, power outage countermeasure, self -diagnosis, automatic cold contact temperature compensation (thermoelectric dating only), sensor disconnection warning, input abnormality | Auto tuning PID, PI, PD, P, ON/OFF | Non -contact voltage | ・ Within ± 0.2%± 1 digit of each input span | Mounting bracket: Thickness of screw type, mounting panel: within 1 to 15mm | 35 ~ 85%RH (not condensation) | 100 ~ 240V AC 50/60Hz | 250ms | ・ Within ± 0.1%± 1 digit or within ± 1 ° C (2 ° F) of each input span | ・ Within ± 0.2%± 1 digit or within ± 2 ° C (4 ° F) of each input span | ・ However, the range of 0 to 200 ° C (32 to 392 ° F) by R or S input is within ± 6 ° C (12 ° F) ・ The range of 0 to 300 ° C (32 to 572 ° F) by B input. Out of accuracy guarantee range | ・ K, J, E, T, N input is less than 0 ° C (32 ° F) within ± 0.4%± 1 digit or ± 4 ° C (8 ° F) of the input span. | ・ No warning, maximum operation, lower limit operation, waiting motion limit operation, waiting lower limit operation, up and down limited operation, up and lower range operation, upwards and lower and lower operations | ・ Absolute price maximum operation, absolute price lower operation, excitation/non -magnetic selection can be selected by key operation. | ・ Thermal electricity vs. K, J, R, S, B, E, T, N, PL-I, C (W/Re5-26) ・ Temperature resistance body: PT100, JPT100 ・ DC current: 4 ~ 20mA DC, 0 ~ 20mA DC / DC voltage: 0 ~ 1V DC, 0 ~ 10V DC, 1 ~ 5V DC, 0 ~ 5V DC | Approximately 300g | Warning 2, Loop abnormal alarm | Approximately 8VA | |
JCM-33A-R/M, W (20A) |
Available upon quote | 0 to 50 ℃ | Sensor correction, set value lock, power outage countermeasure, self -diagnosis, automatic cold contact temperature compensation (thermoelectric dating only), sensor disconnection warning, input abnormality | Auto tuning PID, PI, PD, P, ON/OFF | DC current | ・ Within ± 0.2%± 1 digit of each input span | Mounting bracket: Thickness of screw type, mounting panel: within 1 to 15mm | 35 ~ 85%RH (not condensation) | 100 ~ 240V AC 50/60Hz | 250ms | ・ Within ± 0.1%± 1 digit or within ± 1 ° C (2 ° F) of each input span | ・ Within ± 0.2%± 1 digit or within ± 2 ° C (4 ° F) of each input span | ・ However, the range of 0 to 200 ° C (32 to 392 ° F) by R or S input is within ± 6 ° C (12 ° F) ・ The range of 0 to 300 ° C (32 to 572 ° F) by B input. Out of accuracy guarantee range | ・ K, J, E, T, N input is less than 0 ° C (32 ° F) within ± 0.4%± 1 digit or ± 4 ° C (8 ° F) of the input span. | ・ No warning, maximum operation, lower limit operation, waiting motion limit operation, waiting lower limit operation, up and down limited operation, up and lower range operation, upwards and lower and lower operations | ・ Absolute price maximum operation, absolute price lower operation, excitation/non -magnetic selection can be selected by key operation. | ・ Thermal electricity vs. K, J, R, S, B, E, T, N, PL-I, C (W/Re5-26) ・ Temperature resistance body: PT100, JPT100 ・ DC current: 4 ~ 20mA DC, 0 ~ 20mA DC / DC voltage: 0 ~ 1V DC, 0 ~ 10V DC, 1 ~ 5V DC, 0 ~ 5V DC | Approximately 300g | Hita disconnection warning (rated current 20A) | Approximately 8VA | |
JCM-33A-S/M, C5 |
Available upon quote | 0 to 50 ℃ | Sensor correction, set value lock, power outage countermeasure, self -diagnosis, automatic cold contact temperature compensation (thermoelectric dating only), sensor disconnection warning, input abnormality | Auto tuning PID, PI, PD, P, ON/OFF | Non -contact voltage | ・ Within ± 0.2%± 1 digit of each input span | Mounting bracket: Thickness of screw type, mounting panel: within 1 to 15mm | 35 ~ 85%RH (not condensation) | 100 ~ 240V AC 50/60Hz | 250ms | ・ Within ± 0.1%± 1 digit or within ± 1 ° C (2 ° F) of each input span | ・ Within ± 0.2%± 1 digit or within ± 2 ° C (4 ° F) of each input span | ・ However, the range of 0 to 200 ° C (32 to 392 ° F) by R or S input is within ± 6 ° C (12 ° F) ・ The range of 0 to 300 ° C (32 to 572 ° F) by B input. Out of accuracy guarantee range | ・ K, J, E, T, N input is less than 0 ° C (32 ° F) within ± 0.4%± 1 digit or ± 4 ° C (8 ° F) of the input span. | ・ No warning, maximum operation, lower limit operation, waiting motion limit operation, waiting lower limit operation, up and down limited operation, up and lower range operation, upwards and lower and lower operations | ・ Absolute price maximum operation, absolute price lower operation, excitation/non -magnetic selection can be selected by key operation. | ・ Thermal electricity vs. K, J, R, S, B, E, T, N, PL-I, C (W/Re5-26) ・ Temperature resistance body: PT100, JPT100 ・ DC current: 4 ~ 20mA DC, 0 ~ 20mA DC / DC voltage: 0 ~ 1V DC, 0 ~ 10V DC, 1 ~ 5V DC, 0 ~ 5V DC | Approximately 300g | Serial communication (EIA RS-485) | Approximately 8VA |
Click on the part number for more information about each product