About This Product

This is an energy -saving management flow meter that ensures that a small flow rate of utility gas such as air and nitrogen (call diameter 15mm: 10L/min (normal) ~] is measured. For example, by assembling it into an air piping, measuring the amount of air leak, and converting it to the amount, the amount of air used and the consumption of unwanted air can be grasped digitally, and energy -saving measures are more efficient. A requirement of a small diameter and an essential flow meter for energy -saving management has been realized.

■ Overview

・ Realized the range of "1:60" with super wide range (10 to 600 (15mm), 135 ~ 8,000 (50mm) L/min (normal)] that is unrivaled. It is definitely detected from a small flow, so it is ideal not only for management of the amount used but also for discovery of air leaks. -The temperature and pressure correction are not required for thermal mass flow, which detects mass flow rate. Normal flow rate (0 ° C, 1ATM) is displayed directly, so it is inexpensive. -The display is added to the "yen conversion display" functions in addition to "integration", "cumulative integration" and "instant flow rate (every hour, every minute)". -Sensor elements are protected by stainless steel sespipes, so they have a strong structure for dust, mist, etc.

  • Product

    Energy -saving management flow meter for "flow rate" monitoring of air and nitrogen

Share this product


450+ people viewing

Last viewed: 9 hours ago


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

5 Models of Energy -saving management flow meter for "flow rate" monitoring of air and nitrogen

Click on the part number for more information about each product

Image Part Number Price (excluding tax) Nominal diameter connection Flow range (L/Min (normal)) Operating temperature limit Used pressure range Accuracy (linear) power supply Body material output structure Applicable fluid
Energy -saving management flow meter for "flow rate" monitoring of air and nitrogen-Part Number-TF1015

TF1015

Available upon quote

15mm

RC1/2

10 ~ 600

0 to 50 ℃

0 ~ 0.7MPa

Happiness of 40 % or less of full scale: ± 2 % of full scale, 40 % or more of full scale: ± 5 % of the amount represented

DC power supply

PBT resin

Analog, pulse

Non -explosion, indoor, IP65

Compressed air, nitrogen

Energy -saving management flow meter for "flow rate" monitoring of air and nitrogen-Part Number-TF1020

TF1020

Available upon quote

20mm

RC3/4

15 ~ 800

0 to 50 ℃

0 ~ 0.7MPa

Happiness of 40 % or less of full scale: ± 2 % of full scale, 40 % or more of full scale: ± 5 % of the amount represented

DC power supply

PBT resin

Analog, pulse

Non -explosion, indoor, IP65

Compressed air, nitrogen

Energy -saving management flow meter for "flow rate" monitoring of air and nitrogen-Part Number-TF1025

TF1025

Available upon quote

25mm

RC1

35 ~ 2,200

0 to 50 ℃

0 ~ 0.7MPa

Happiness of 40 % or less of full scale: ± 2 % of full scale, 40 % or more of full scale: ± 5 % of the amount represented

DC power supply

Aluminum (cutting)

Analog, pulse

Non -explosion, indoor, IP65 equivalent

Compressed air, nitrogen

Energy -saving management flow meter for "flow rate" monitoring of air and nitrogen-Part Number-TF1040

TF1040

Available upon quote

40mm

RC1 ・ 1/2

85 ~ 5,000

0 to 50 ℃

0 ~ 0.7MPa

Happiness of 40 % or less of full scale: ± 2 % of full scale, 40 % or more of full scale: ± 5 % of the amount represented

DC power supply

Aluminum (cutting)

Analog, pulse

Non -explosion, indoor, IP65 equivalent

Compressed air, nitrogen

Energy -saving management flow meter for "flow rate" monitoring of air and nitrogen-Part Number-TF1050

TF1050

Available upon quote

50mm

RC2

135 ~ 8,000

0 to 50 ℃

0 ~ 0.7MPa

Happiness of 40 % or less of full scale: ± 2 % of full scale, 40 % or more of full scale: ± 5 % of the amount represented

DC power supply

Aluminum (cutting)

Analog, pulse

Non -explosion, indoor, IP65 equivalent

Compressed air, nitrogen

Click on the part number for more information about each product

Customers who viewed this product also viewed

Reviews shown here are reviews of companies.

See More Flowmeters Products

Other products of OVAL Corporation

Reviews shown here are reviews of companies.


View more products of OVAL Corporation

About Company Handling This Product

Response Rate

100.0%


Response Time

23.1hrs

Company Overview

OVAL Corporation, founded in Tokyo, Japan, in 1949 is a manufacturer of metrological control equipment and rel...

See More

  • Japan

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree