Battery -type EX Delta II unnecessary external power supply so that EX delta II as a dedicated field monitor -only machine, which is frequently used in various fields, can be used more easily by taking advantage of the versatility of the whirlpool. A model designed so that it can be used only with batteries. In the display, the integrated value and instant flow rate can be switched monitor with an external switch. There is also a separate type that allows you to focus on a place where you can concentrate on a maximum of 50m away from the scattered flow measurement detector. ■ Main features ・ High accurate flow rate measurement is possible within a wide range -The exclusive EX delta II / diamond to prevent scale adhesive deposits by combining a unique rhombus -shaped cross section and separate -type sensor, maintaining stable performance in dirt. ・ Since the detected element does not advertise and has no movable portion, it has excellent durability. ・ Because of the battery -driven type, external power supply work is not required. ・ It has a variety of display functions, including simultaneous display of accumulation / instant flow rate, ball graph display of instantaneous flow, alarm display function including battery life. ・ Because it is a waterproof structure (IP66/67) and it is a pressure -resistant explosionproof structure (EXDIIBH2T1, T4), it is optimal as a flow sensor for on -site monitors. ・ The converter separation type can be intensive monitor in a remote place ■ High performance and support for various applications The combination of a whirlpool generated by a triangle cross section and a piezoelectric element sensor measure the flow rate of liquid, gas, and steam in high accuracy. ■ Easy to use and low cost It has a durable and simple structure, easy to use and has excellent conservative, initial cost, running cost, total cost. ■ High safety Structure with less fluids and few seals. In particular, the replayable sensor can maintain and check the sensor while attaching it to the piping without stopping the flow. ■ Energy saving / space saving Energy -saving effect with small pressure loss, a dedicated rectification device can reduce the installation space.

  • Product

    External power supply that can not be used only with internal batteries EX Delta (standard, battery type, PAF5 type)




*Please note that we may not be able to accommodate sample requests.

8 Models of External power supply that can not be used only with internal batteries EX Delta (standard, battery type, PAF5 type)

Items marked with have different values ​​depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Applicable fluid Body material Flange standard Flow -range liquid (water) Flow -up range gas (0.2MPa air) Flow -up range steam (0.5MPa saturated steam) Maximum use pressure Nominal diameter Operating temperature limit accuracy output power supply structure type
External power supply that can not be used only with internal batteries EX Delta (standard, battery type, PAF5 type)-Part Number-Battery type VXU

Battery type VXU

Available upon quote Liquid, gas, steam SUS316 or SCS14A JIS 10, 20, 30k ASME/JPI 150, 300, 600 0.2 * ~ 2,510m3/h (11 format) ( * The seal is 10mm and accuracy ± 2 % FS) 2 * ~ 15,000m3/h (11 format) ( * The seal is 10mm and accuracy ± 2 % FS) 0.02 ~ 47.6t/h (10 format) (15mm or more) 4.51MPa (with flange standard and flange material) 15 ~ 300mm -30 ~ + 300 ° C, -30 ~ + 460 ° C (for high temperature of replayable sensors) ± 1 % of the amount represented or ± 1 % of the full scale Analog, pulse DC power or battery drive Explosion or non -explosion, IP66 (DC power supply), IP65 (battery drive) Flange -type fixed sensor
External power supply that can not be used only with internal batteries EX Delta (standard, battery type, PAF5 type)-Part Number-Battery -type VXT

Battery -type VXT

Available upon quote Liquid, gas, steam SUS316 or SCS14A JIS 10, 20, 30k ASME/JPI 150, 300, 601 0.2 * ~ 2,510m3/h (11 format) ( * The seal is 10mm and accuracy ± 2 % FS) 2 * ~ 15,000m3/h (11 format) ( * The seal is 10mm and accuracy ± 2 % FS) 0.02 ~ 47.6t/h (10 format) (15mm or more) 4.51MPa (with flange standard and flange material) 15 ~ 300mm -30 ~ + 300 ° C, -30 ~ + 460 ° C (for high temperature of replayable sensors) ± 1 % of the amount represented or ± 1 % of the full scale Analog, pulse DC power or battery drive Explosion or non -explosion, IP66 (DC power supply), IP65 (battery drive) Flange -shaped replesable sensor
External power supply that can not be used only with internal batteries EX Delta (standard, battery type, PAF5 type)-Part Number-Battery type VXW

Battery type VXW

Available upon quote Liquid, gas, steam SUS316 or SCS14A JIS 10, 20, 30k ASME/JPI 150, 300, 602 0.2 * ~ 2,510m3/h (11 format) ( * The seal is 10mm and accuracy ± 2 % FS) 2 * ~ 15,000m3/h (11 format) ( * The seal is 10mm and accuracy ± 2 % FS) 0.02 ~ 47.6t/h (10 format) (15mm or more) 4.51MPa (with flange standard and flange material) 10 ~ 150mm (15mm or more for steam) -30 ~ + 300 ° C, -30 ~ + 460 ° C (for high temperature of replayable sensors) ± 1 % of the amount represented or ± 1 % of the full scale Analog, pulse DC power or battery drive Explosion or non -explosion, IP66 (DC power supply), IP65 (battery drive) Wafer -shaped fixing sensor (nominal diameter 10-150mm)
External power supply that can not be used only with internal batteries EX Delta (standard, battery type, PAF5 type)-Part Number-Battery VXF

Battery VXF

Available upon quote Liquid, gas, steam SUS316 or SCS14A JIS 10, 20, 30k ASME/JPI 150, 300, 603 0.2 * ~ 2,510m3/h (11 format) ( * The seal is 10mm and accuracy ± 2 % FS) 2 * ~ 15,000m3/h (11 format) ( * The seal is 10mm and accuracy ± 2 % FS) 0.02 ~ 47.6t/h (10 format) (15mm or more) 4.51MPa (with flange standard and flange material) 15 ~ 300mm -30 ~ + 300 ° C, -30 ~ + 460 ° C (for high temperature of replayable sensors) ± 1 % of the amount represented or ± 1 % of the full scale Analog, pulse DC power or battery drive Explosion or non -explosion, IP66 (DC power supply), IP65 (battery drive) Flange -shaped fixed sensor (rhuan diameter 15mm or more, RF flange standard)
External power supply that can not be used only with internal batteries EX Delta (standard, battery type, PAF5 type)-Part Number-Battery VXR

Battery VXR

Available upon quote Liquid, gas, steam SUS316 or SCS14A JIS 10, 20, 30k ASME/JPI 150, 300, 604 0.2 * ~ 2,510m3/h (11 format) ( * The seal is 10mm and accuracy ± 2 % FS) 2 * ~ 15,000m3/h (11 format) ( * The seal is 10mm and accuracy ± 2 % FS) 0.02 ~ 47.6t/h (10 format) (15mm or more) 4.51MPa (with flange standard and flange material) 15 ~ 300mm -30 ~ + 300 ° C, -30 ~ + 460 ° C (for high temperature of replayable sensors) ± 1 % of the amount represented or ± 1 % of the full scale Analog, pulse DC power or battery drive Explosion or non -explosion, IP66 (DC power supply), IP65 (battery drive) Flange -shaped replacables (RF flange standard, standard RF flange)
External power supply that can not be used only with internal batteries EX Delta (standard, battery type, PAF5 type)-Part Number-Battery -type VXJ

Battery -type VXJ

Available upon quote Liquid, gas, steam SUS316 or SCS14A JIS 10, 20, 30k ASME/JPI 150, 300, 605 0.2 * ~ 2,510m3/h (11 format) ( * The seal is 10mm and accuracy ± 2 % FS) 2 * ~ 15,000m3/h (11 format) ( * The seal is 10mm and accuracy ± 2 % FS) 0.02 ~ 47.6t/h (10 format) (15mm or more) 4.51MPa (with flange standard and flange material) 10 ~ 150mm (15mm or more for steam) -30 ~ + 300 ° C, -30 ~ + 460 ° C (for high temperature of replayable sensors) ± 1 % of the amount represented or ± 1 % of the full scale Analog, pulse DC power or battery drive Explosion or non -explosion, IP66 (DC power supply), IP65 (battery drive) Rhinogata -shaped whirlpool -type wafer -shaped fixing sensor
External power supply that can not be used only with internal batteries EX Delta (standard, battery type, PAF5 type)-Part Number-Battery VXL

Battery VXL

Available upon quote Liquid, gas, steam SUS316 or SCS14A JIS 10, 20, 30k ASME/JPI 150, 300, 606 0.2 * ~ 2,510m3/h (11 format) ( * The seal is 10mm and accuracy ± 2 % FS) 2 * ~ 15,000m3/h (11 format) ( * The seal is 10mm and accuracy ± 2 % FS) 0.02 ~ 47.6t/h (10 format) (15mm or more) 4.51MPa (with flange standard and flange material) 15 ~ 300mm -30 ~ + 300 ° C, -30 ~ + 460 ° C (for high temperature of replayable sensors) ± 1 % of the amount represented or ± 1 % of the full scale Analog, pulse DC power or battery drive Explosion or non -explosion, IP66 (DC power supply), IP65 (battery drive) Rhinodent whirlpool -type flange -type fixed sensor (order design)
External power supply that can not be used only with internal batteries EX Delta (standard, battery type, PAF5 type)-Part Number-Battery type VXM

Battery type VXM

Available upon quote Liquid, gas, steam SUS316 or SCS14A JIS 10, 20, 30k ASME/JPI 150, 300, 607 0.2 * ~ 2,510m3/h (11 format) ( * The seal is 10mm and accuracy ± 2 % FS) 2 * ~ 15,000m3/h (11 format) ( * The seal is 10mm and accuracy ± 2 % FS) 0.02 ~ 47.6t/h (10 format) (15mm or more) 4.51MPa (with flange standard and flange material) 15 ~ 300mm -30 ~ + 300 ° C, -30 ~ + 460 ° C (for high temperature of replayable sensors) ± 1 % of the amount represented or ± 1 % of the full scale Analog, pulse DC power or battery drive Explosion or non -explosion, IP66 (DC power supply), IP65 (battery drive) Rhinodo -shaped vortex flange -type replayable sensor (order design)

Click on the part number for more information about each product

Customers who viewed this product also viewed

Other products of OVAL Corporation


View more products of OVAL Corporation

About Company Handling This Product

OVAL Corporation

  • Japan
  • Since 1949
  • 669 employees

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree