All Categories

History

Linear sensor radiation thermometer LTH1 series
-LTH1-CNN0400-0120H0.6-046S
Linear sensor radiation thermometer LTH1 series
-Japan Sensor

Linear sensor radiation thermometer LTH1 series
Japan Sensor

Japan Sensor's Response Status

Response Rate

100.0%

Response Time

31.9hours

Relatively Fast Response


About This Product

The linear sensor thermometer LTH series developed by the Japan Sensor is a thermometer that allows you to measure multiple points on a straight line at the same time. You can check the image and save data with the attached software.

■ Measures multiple points on a straight line simultaneously with one unit

The linear sensor thermometer developed by the Japan Sensor is a thermometer that can simultaneously measure multiple points on a straight line. ・ Simultaneous measurement of multiple points on a straight line ・ Do not miss the moving items ・ You can perform analog output and alarm output set for each sector ・ Compact size ・ Image confirmation with attached software ・ Save data <Product features>

■ Simultaneous measurement of multiple points on a straight line

The linear sensor thermometer developed by the Japan Sensor is a thermometer that can simultaneously measure multiple points on a straight line by installing 46 sensors in one row. It can be measured at 1kHz (1 ms per sensor). You can measure the moving objects without missing. (MAX150Hz MAX150HZ manufactured by other companies)

■ Analog output and alarm output set for each sector can be performed

The linear sensor thermometer has a function called a sector. By allocating 46 sensors to up to eight sectors, analog outputs and alarm output set for each sector can be performed.

■ Compact size as much as milk pack

It is a compact size of 154 x 86 x 92. It is as large as a 500ml milk pack.

■ Image confirmation and data saving with attached software

Image confirmation and data saving can be performed with the included software.

  • Product

    Linear sensor radiation thermometer LTH1 series

Share this product


460+ people viewing

Last viewed: 6 hours ago


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

6 Models of Linear sensor radiation thermometer LTH1 series

Click on the part number for more information about each product

Image Part Number Price (excluding tax) Measurement range Aim Effective wavelength Detection element Measured distance response speed Number of elements Analog output 8ch RS485 output Alarm output Hold function Radioactivity correction Sensor correction function Warm -up time structure Used peripheral temperature Approximately used humidity Save surrounding temperature Power-supply voltage mass
Linear sensor radiation thermometer LTH1 series
-Part Number-LTH1-CNN0400-0120H0.6-046S

LTH1-CNN0400-0120H0.6-046S

Available upon quote

50-400 ℃

Scan width: 28mm

3.0 to 5.0 μm

INASSB

120mm

Frequency: 1kHz

46

Select from 0 ~ 20ma, 4 ~ 20mA, 0 ~ 5V, 0 ~ 10V, MV/℃, 10mv/℃

Communication speed: 9,600bps ~ 6,000,000bps (6Mbps)

Photomoslille 2 points DC27V, 0.1a Max,
Hysteresis setting width: 0 ~ 99.9 ℃

Peak hold, Valley Hold, Sample Hold

Warranty range 0.3 ~ 1.0 Set range 0.050 ~ 1.000 (Settings decomposition No ¥ 0.001),
With reflective correction function

Span: 0.500 ~ 2,000, zero: -50 ~+50 ° C (° f)

5 minutes

Dustproof (equivalent to IP67)

0 to 50 ℃

30-85%RH (without condensation)

-15 ~ 70 ° C

DC24V, 0.5A MAX

950g

Linear sensor radiation thermometer LTH1 series
-Part Number-LTH1-CNN0400-0300H1.9-046S

LTH1-CNN0400-0300H1.9-046S

Available upon quote

50-400 ℃

Scan width: 90mm

3.0 to 5.0 μm

INASSB

300mm

Frequency: 1kHz

46

Select from 0 ~ 20ma, 4 ~ 20mA, 0 ~ 5V, 0 ~ 10V, MV/℃, 10mv/℃

Communication speed: 9,600bps ~ 6,000,000bps (6Mbps)

Photomoslille 2 points DC27V, 0.1a Max,
Hysteresis setting width: 0 ~ 99.9 ℃

Peak hold, Valley Hold, Sample Hold

Warranty range 0.3 ~ 1.0 Set range 0.050 ~ 1.000 (Settings decomposition No ¥ 0.001),
With reflective correction function

Span: 0.500 ~ 2,000, zero: -50 ~+50 ° C (° f)

5 minutes

Dustproof (equivalent to IP67)

0 to 50 ℃

30-85%RH (without condensation)

-15 ~ 70 ° C

DC24V, 0.5A MAX

950g

Linear sensor radiation thermometer LTH1 series
-Part Number-LTH1-CNN0400-0700H006-046s

LTH1-CNN0400-0700H006-046s

Available upon quote

50-400 ℃

Scan width: 280mm

3.0 to 5.0 μm

INASSB

700mm

Frequency: 1kHz

46

Select from 0 ~ 20ma, 4 ~ 20mA, 0 ~ 5V, 0 ~ 10V, MV/℃, 10mv/℃

Communication speed: 9,600bps ~ 6,000,000bps (6Mbps)

Photomoslille 2 points DC27V, 0.1a Max,
Hysteresis setting width: 0 ~ 99.9 ℃

Peak hold, Valley Hold, Sample Hold

Warranty range 0.3 ~ 1.0 Set range 0.050 ~ 1.000 (Settings decomposition No 0.001), with reflection correction function

Span: 0.500 ~ 2,000, zero: -50 ~+50 ° C (° f)

5 minutes

Dustproof (equivalent to IP67)

0 to 50 ℃

30-85%RH (without condensation)

-15 ~ 70 ° C

DC24V, 0.5A MAX

950g

Linear sensor radiation thermometer LTH1 series
-Part Number-LTH1-PNN0400-0450H1.4-046S

LTH1-PNN0400-0450H1.4-046S

Available upon quote

400-900 ° C

Scan width: 64mm

0.8-1.6μm

INGAAS

450mm

Frequency: 1kHz

46

Select from 0 ~ 20ma, 4 ~ 20mA, 0 ~ 5V, 0 ~ 10V, MV/℃, 10mv/℃

Communication speed: 9,600bps ~ 6,000,000bps (6Mbps)

Photomoslille 2 points DC27V, 0.1a Max,
Hysteresis setting width: 0 ~ 99.9 ℃

Peak hold, Valley Hold, Sample Hold

Warranty range 0.3 ~ 1.0 Set range 0.050 ~ 1.000 (Settings decomposition No ¥ 0.001),
With reflective correction function

Span: 0.500 ~ 2,000, zero: -50 ~+50 ° C (° f)

5 minutes

Dustproof (equivalent to IP67)

0 to 50 ℃

30-85%RH (without condensation)

-15 ~ 70 ° C

DC24V, 0.5A MAX

950g

Linear sensor radiation thermometer LTH1 series
-Part Number-LTH1-PNN0400-0500H2.8-046s

LTH1-PNN0400-0500H2.8-046s

Available upon quote

400-900 ° C

Scan width: 130mm

0.8-1.6μm

INGAAS

500mm

Frequency: 1kHz

46

Select from 0 ~ 20ma, 4 ~ 20mA, 0 ~ 5V, 0 ~ 10V, MV/℃, 10mv/℃

Communication speed: 9,600bps ~ 6,000,000bps (6Mbps)

Photomoslille 2 points DC27V, 0.1a Max,
Hysteresis setting width: 0 ~ 99.9 ℃

Peak hold, Valley Hold, Sample Hold

Warranty range 0.3 ~ 1.0 Set range 0.050 ~ 1.000 (Settings decomposition No ¥ 0.001),
With reflective correction function

Span: 0.500 ~ 2,000, zero: -50 ~+50 ° C (° f)

5 minutes

Dustproof (equivalent to IP67)

0 to 50 ℃

30-85%RH (without condensation)

-15 ~ 70 ° C

DC24V, 0.5A MAX

950g

Linear sensor radiation thermometer LTH1 series
-Part Number-LTH1-PNN0650-0500H2.8-046S

LTH1-PNN0650-0500H2.8-046S

Available upon quote

650-1500 ° C

Scan width: 130mm

0.8-1.6μm

INGAAS

500mm

Frequency: 1kHz

46

Select from 0 ~ 20ma, 4 ~ 20mA, 0 ~ 5V, 0 ~ 10V, MV/℃, 10mv/℃

Communication speed: 9,600bps ~ 6,000,000bps (6Mbps)

Photomoslille 2 points DC27V, 0.1a Max,
Hysteresis setting width: 0 ~ 99.9 ℃

Peak hold, Valley Hold, Sample Hold

Warranty range 0.3 ~ 1.0 Set range 0.050 ~ 1.000 (Settings decomposition No ¥ 0.001),
With reflective correction function

Span: 0.500 ~ 2,000, zero: -50 ~+50 ° C (° f)

5 minutes

Dustproof (equivalent to IP67)

0 to 50 ℃

30-85%RH (without condensation)

-15 ~ 70 ° C

DC24V, 0.5A MAX

950g

Click on the part number for more information about each product

Customers who viewed this product also viewed

Reviews shown here are reviews of companies.

See More Non-Contact Temperature Sensors Products

Other products of Japan Sensor

Reviews shown here are reviews of companies.


View more products of Japan Sensor

About Company Handling This Product

Response Rate

100.0%


Response Time

31.9hrs

Company Overview

Japan Sensor Corporation, founded in 1972, is a Japanese manufacturer based in Minato-ku, Tokyo, specializing ...

See More

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree