Heat resistance 180 ℃ Explosion -proof radiation thermometer EXM8 series-EXM8-21-LT-5
Heat resistance 180 ℃ Explosion -proof radiation thermometer EXM8 series-Japan Sensor

Heat resistance 180 ℃ Explosion -proof radiation thermometer EXM8 series
Japan Sensor


About This Product

Characteristics of the product Heat resistance temperature 180 ° C ・ Maximum atmosphere temperature, small sensor head that can be used at 180 ° C! ・ Dangerous gas atmosphere, Zone 0 can be installed in Zone 0 and Zone 1 can be set up in Zone 1 ・ Temperature measurement range: -20 ° C to + 1000 ° C ・ Response speed: 240msec ・ Output: 4-20mA ・ Settings: 4-20 mA scaling temperature setting, radioactivity setting, etc. are possible using the optional communication interface. Can be installed in Zone 0 by explosion -proof Dangerous place You can install an amplifier unit in Zone 0 and Zone 1 Because of the explosion -proof shape, it can be installed in an atmosphere with combustible materials such as solvent, such as a chemical plant and resin factory. With the essential safety -proof authentication number of TIIS, ATEX, and IECEX, it can be used in Japan, Europe and other countries around the world that accept IECEX international explosion proof. Use with the essential safety explosion -proof insulator This product must be used in combination with the essential safety explosion -proof insulation baria (D5014S/D5014D). ・ Insulated barrier installation and wiring terminal: T35DIN rail (en50022 compliant) ・ Can be attached to power buses and terminal boards ・ Compatible wires: 0.25mm² to 2.5mm², recommended tightening torque: 0.5N / m to 0.6N / m Free setting is possible for radiation rates and 4-20ma scaling with optional devices Using the USB interface (LCT mobile unit) or the RS485 interface (LCT-485 unit) of optional devices, radiation ratio, 4-20ma scaling, etc. can be freely set. Since only the EXTEMP series is authenticated as an essential safety explosion -proof device, the LCT configuration should be used on the safety location circuit. The configuration items are radiation rates, 4-20mA scaling, average, peak and valley values ​​and reflectors. * In addition to this page, there is a part number.

  • Product

    Heat resistance 180 ℃ Explosion -proof radiation thermometer EXM8 series




*Please note that we may not be able to accommodate sample requests.

12 Models of Heat resistance 180 ℃ Explosion -proof radiation thermometer EXM8 series

Items marked with have different values ​​depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) EMC conformity External dimensions Maximum connection number Maximum current Mounting method Supply power supply Temperature measurement range Used peripheral temperature baud rate connection output protocol response speed setting
Heat resistance 180 ℃ Explosion -proof radiation thermometer EXM8 series-Part Number-EXM8-21-LT-5

EXM8-21-LT-5

Available upon quote Bsen61326-1: 2012 & EN61326-2: 2013 Approximately 114 (depth) x 18 (width) x 107 (height) Up to 224 units per Modbus master 50ma DIN rail, 35mm 6 to 28VDC -20 ℃ ~ + 1000 ℃ (-) 20 ℃ ~+70 ℃ 1,200 ~ 57,600bps, automatic inspection Power and radiation temperature meter 4-20mA, screw terminal 4 ~ 20ma MODBUS RTU slave 240msec Using the optional communication interface, it is possible to set the temperature range of 4 to 20 mA scaling and set radiation ratings.
Heat resistance 180 ℃ Explosion -proof radiation thermometer EXM8 series-Part Number-EXM8-21-LT-10

EXM8-21-LT-10

Available upon quote Bsen61326-1: 2012 & EN61326-2: 2013 Approximately 114 (depth) x 18 (width) x 107 (height) Up to 224 units per Modbus master 50ma DIN rail, 35mm 6 to 28VDC -20 ℃ ~ + 1000 ℃ (-) 20 ℃ ~+70 ℃ 1,200 ~ 57,600bps, automatic inspection Power and radiation temperature meter 4-20mA, screw terminal 4 ~ 20ma MODBUS RTU slave 240msec Using the optional communication interface, it is possible to set the temperature range of 4 to 20 mA scaling and set radiation ratings.
Heat resistance 180 ℃ Explosion -proof radiation thermometer EXM8 series-Part Number-EXM8-21-LT-25

EXM8-21-LT-25

Available upon quote Bsen61326-1: 2012 & EN61326-2: 2013 Approximately 114 (depth) x 18 (width) x 107 (height) Up to 224 units per Modbus master 50ma DIN rail, 35mm 6 to 28VDC -20 ℃ ~ + 1000 ℃ (-) 20 ℃ ~+70 ℃ 1,200 ~ 57,600bps, automatic inspection Power and radiation temperature meter 4-20mA, screw terminal 4 ~ 20ma MODBUS RTU slave 240msec Using the optional communication interface, it is possible to set the temperature range of 4 to 20 mA scaling and set radiation ratings.
Heat resistance 180 ℃ Explosion -proof radiation thermometer EXM8 series-Part Number-Exm8-21-MT-5

Exm8-21-MT-5

Available upon quote Bsen61326-1: 2012 & EN61326-2: 2013 Approximately 114 (depth) x 18 (width) x 107 (height) Up to 224 units per Modbus master 50ma DIN rail, 35mm 6 to 28VDC -20 ℃ ~ + 1000 ℃ (-) 20 ℃ ~+70 ℃ 1,200 ~ 57,600bps, automatic inspection Power and radiation temperature meter 4-20mA, screw terminal 4 ~ 20ma MODBUS RTU slave 240msec Using the optional communication interface, it is possible to set the temperature range of 4 to 20 mA scaling and set radiation ratings.
Heat resistance 180 ℃ Explosion -proof radiation thermometer EXM8 series-Part Number-Exm8-21-MT-10

Exm8-21-MT-10

Available upon quote Bsen61326-1: 2012 & EN61326-2: 2013 Approximately 114 (depth) x 18 (width) x 107 (height) Up to 224 units per Modbus master 50ma DIN rail, 35mm 6 to 28VDC -20 ℃ ~ + 1000 ℃ (-) 20 ℃ ~+70 ℃ 1,200 ~ 57,600bps, automatic inspection Power and radiation temperature meter 4-20mA, screw terminal 4 ~ 20ma MODBUS RTU slave 240msec Using the optional communication interface, it is possible to set the temperature range of 4 to 20 mA scaling and set radiation ratings.
Heat resistance 180 ℃ Explosion -proof radiation thermometer EXM8 series-Part Number-EXM8-21-MT-25

EXM8-21-MT-25

Available upon quote Bsen61326-1: 2012 & EN61326-2: 2013 Approximately 114 (depth) x 18 (width) x 107 (height) Up to 224 units per Modbus master 50ma DIN rail, 35mm 6 to 28VDC -20 ℃ ~ + 1000 ℃ (-) 20 ℃ ~+70 ℃ 1,200 ~ 57,600bps, automatic inspection Power and radiation temperature meter 4-20mA, screw terminal 4 ~ 20ma MODBUS RTU slave 240msec Using the optional communication interface, it is possible to set the temperature range of 4 to 20 mA scaling and set radiation ratings.
Heat resistance 180 ℃ Explosion -proof radiation thermometer EXM8 series-Part Number-Exm8-21-HT-5

Exm8-21-HT-5

Available upon quote Bsen61326-1: 2012 & EN61326-2: 2013 Approximately 114 (depth) x 18 (width) x 107 (height) Up to 224 units per Modbus master 50ma DIN rail, 35mm 6 to 28VDC -20 ℃ ~ + 1000 ℃ (-) 20 ℃ ~+70 ℃ 1,200 ~ 57,600bps, automatic inspection Power and radiation temperature meter 4-20mA, screw terminal 4 ~ 20ma MODBUS RTU slave 240msec Using the optional communication interface, it is possible to set the temperature range of 4 to 20 mA scaling and set radiation ratings.
Heat resistance 180 ℃ Explosion -proof radiation thermometer EXM8 series-Part Number-Exm8-21-HT-10

Exm8-21-HT-10

Available upon quote Bsen61326-1: 2012 & EN61326-2: 2013 Approximately 114 (depth) x 18 (width) x 107 (height) Up to 224 units per Modbus master 50ma DIN rail, 35mm 6 to 28VDC -20 ℃ ~ + 1000 ℃ (-) 20 ℃ ~+70 ℃ 1,200 ~ 57,600bps, automatic inspection Power and radiation temperature meter 4-20mA, screw terminal 4 ~ 20ma MODBUS RTU slave 240msec Using the optional communication interface, it is possible to set the temperature range of 4 to 20 mA scaling and set radiation ratings.
Heat resistance 180 ℃ Explosion -proof radiation thermometer EXM8 series-Part Number-EXM8-21-HT-25

EXM8-21-HT-25

Available upon quote Bsen61326-1: 2012 & EN61326-2: 2013 Approximately 114 (depth) x 18 (width) x 107 (height) Up to 224 units per Modbus master 50ma DIN rail, 35mm 6 to 28VDC -20 ℃ ~ + 1000 ℃ (-) 20 ℃ ~+70 ℃ 1,200 ~ 57,600bps, automatic inspection Power and radiation temperature meter 4-20mA, screw terminal 4 ~ 20ma MODBUS RTU slave 240msec Using the optional communication interface, it is possible to set the temperature range of 4 to 20 mA scaling and set radiation ratings.
Heat resistance 180 ℃ Explosion -proof radiation thermometer EXM8 series-Part Number-EXM8-21-XT-5

EXM8-21-XT-5

Available upon quote Bsen61326-1: 2012 & EN61326-2: 2013 Approximately 114 (depth) x 18 (width) x 107 (height) Up to 224 units per Modbus master 50ma DIN rail, 35mm 6 to 28VDC -20 ℃ ~ + 1000 ℃ (-) 20 ℃ ~+70 ℃ 1,200 ~ 57,600bps, automatic inspection Power and radiation temperature meter 4-20mA, screw terminal 4 ~ 20ma MODBUS RTU slave 240msec Using the optional communication interface, it is possible to set the temperature range of 4 to 20 mA scaling and set radiation ratings.
Heat resistance 180 ℃ Explosion -proof radiation thermometer EXM8 series-Part Number-EXM8-21-XT-10

EXM8-21-XT-10

Available upon quote Bsen61326-1: 2012 & EN61326-2: 2013 Approximately 114 (depth) x 18 (width) x 107 (height) Up to 224 units per Modbus master 50ma DIN rail, 35mm 6 to 28VDC -20 ℃ ~ + 1000 ℃ (-) 20 ℃ ~+70 ℃ 1,200 ~ 57,600bps, automatic inspection Power and radiation temperature meter 4-20mA, screw terminal 4 ~ 20ma MODBUS RTU slave 240msec Using the optional communication interface, it is possible to set the temperature range of 4 to 20 mA scaling and set radiation ratings.
Heat resistance 180 ℃ Explosion -proof radiation thermometer EXM8 series-Part Number-EXM8-21-XT-25

EXM8-21-XT-25

Available upon quote Bsen61326-1: 2012 & EN61326-2: 2013 Approximately 114 (depth) x 18 (width) x 107 (height) Up to 224 units per Modbus master 50ma DIN rail, 35mm 6 to 28VDC -20 ℃ ~ + 1000 ℃ (-) 20 ℃ ~+70 ℃ 1,200 ~ 57,600bps, automatic inspection Power and radiation temperature meter 4-20mA, screw terminal 4 ~ 20ma MODBUS RTU slave 240msec Using the optional communication interface, it is possible to set the temperature range of 4 to 20 mA scaling and set radiation ratings.

Click on the part number for more information about each product

Other products of Japan Sensor


View more products of Japan Sensor

About Company Handling This Product

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree