Fiber type radiation thermometer FTKX series-FTKX-TNE0100
Fiber type radiation thermometer FTKX series-Japan Sensor

Fiber type radiation thermometer FTKX series
Japan Sensor


About This Product

The Japan Sensor's Fiber -type radiation thermometer FTKX series can be selected according to your desired specifications from a combination of 140 patterns or more. A semi -order type radiation thermometer that can be used in any scene. The world's highest -class high -speed response 1 ms (0.001 seconds) can surely measure the temperature in the temperature of the measurement and vacuum tank through the window. ■ Semi -order type radiation thermometer that can be used in every scene The Japan Sensor's Fiber -type radiation thermometer FTKX series can be selected according to your desired specifications from a combination of 140 patterns or more. ・ Semi -order type corresponds to all scenes ・ Sensor head, fiber, temperature converter, etc. are separated, so it is easy to install ・ A wide variety of temperature measurement range of 100 ° C to 2000 ° C (9 types) (Custom -made can be used for over 2000 ° C) ・ Φ0.15mm ~ You can also aim small work ・ Surely measure temperature with the world's highest class high -speed response 1ms (0.001s) ・ Measurement through windows can be measured ・ Green LED is easier to see than before and easy to adjust ・ Challenge the bad environment with a sturdy body ・ Fiber strength up ・ Heat resistance temperature 150 ℃ ・ Equipped with both analog output and RS232C output ・ Optical aiming head that can be aligned visually ・ Accessories for optical aiming heads ・ CE Marking Compatible ■ Semi -order type can be used for specifications of 140 or more patterns By changing the combination of sensor head, fiber, temperature converter, you can choose the temperature range, measurement distance, target size, etc. as a semi -order. It can be used for specifications with 140 or more patterns. ■ Sensor head and fiber can be separated, so it can be used for small places and places that are difficult to install. Sensor head, fiber, fiber and temperature converter are now removable. Because it is a small and lightweight head, it can be used for narrow places and places that are difficult to install. ■ A wide variety of temperature measurement range A wide variety of temperature measurement range of 100 ° C to 2000 ° C (9 types) (Custom -made can be used for over 2000 ° C) ■ You can also aim small work Target size φ0.15mm ~. The optical system has been reviewed and smaller spots can be measured. ■ World's highest class high -speed response 1ms (0.001s) The world's highest -class high -speed response 1ms (0.001s) will not overlook the sudden temperature change. ■ Temperature measurement through quartz glass is possible In the case of a thermometer using a long wavelength with a measurement wavelength of about 10 μm, the temperature of the quartz glass itself is measured. Since the FTKX series uses a short wave length (0.8 to 2.5 μm), quartz glass transmits more than 90%. The temperature in the vacuum tank can be measured through the window. ■ Easy positioning The "optical axis LED aiming method" adopted by the FTKX series can be easily aligned because the temperature measurement range is close to the eye. In addition, it is easier to adjust the position even in the red part at high temperature by adopting a green LED. It is possible to aim LED even during temperature measurement. There are many other features.

  • Product

    Fiber type radiation thermometer FTKX series




*Please note that we may not be able to accommodate sample requests.

9 Models of Fiber type radiation thermometer FTKX series

Items marked with have different values ​​depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Accuracy rating Aim Alarm output Approximately used humidity Detection element Effective wavelength Measurement and decomposition ability Peak hold Power-supply voltage RS232C output Radioactivity correction Reproducibility Response time Save surrounding temperature Sensor correction function Temperature display Temperature range Used peripheral temperature Warm -up time structure
Fiber type radiation thermometer FTKX series-Part Number-FTKX-TNE0100

FTKX-TNE0100

Available upon quote Less than 800 ° C: ± 4 ℃,
800 to 1,200 ° C: ± 0.5%of measured values,
1,200 super ~ 2,000 ° C: ± 1.0% of measured values
Green LED aim Orbund train 1 point DC 27V, 0.2A,
Hysteresis setting width: 0 ~ 99.9 ℃
30-85%RH (without condensation) INGAAS 1.95 ~ 2.5 μm The minimum temperature+50 ℃: 3 ° C or less,
The minimum temperature+100 ° C less than 100 ° C: 1 ° C or less,
Minimum temperature+100 ° C or higher: 0.5 ° C or less
Reset method-
Time: 0.01 ~ 10 seconds variable discharge: Time 0.01 ~ 10 seconds, level 0.2 ~ 1.0
DC4.7 ~ 27V, 0.1a Max Output swing width: about ± 4V,
Communication speed: 4,800 9,600 19,200 38,400 57,600 115,200bps
Warranty range 0.3 ~ 1.0 Set range 0.050 ~ 1.000 (Settings decomposition No 0.001) ± 0.2% ± 2 ℃ of the measured value The minimum temperature+50 ℃: 3 ° C or less,
The minimum temperature+100 ° C less than 100 ° C: 1 ° C or less,
Minimum temperature+100 ° C or higher: 0.5 ° C or less
-15 ~ 70 ° C Span: 0.500 ~ 2,000, zero: -50 ~+50 ° C (° f) none 100 ~ 1,500 ° C 0 to 50 ℃ 1 minute Excludes dustproof (equivalent to IP67) and e-conf connectors
Fiber type radiation thermometer FTKX series-Part Number-FTKX-TNE0180

FTKX-TNE0180

Available upon quote Less than 800 ° C: ± 4 ℃,
800 to 1,200 ° C: ± 0.5%of measured values,
1,200 super ~ 2,000 ° C: ± 1.0% of measured values
Green LED aim Orbund train 1 point DC 27V, 0.2A,
Hysteresis setting width: 0 ~ 99.9 ℃
30-85%RH (without condensation) INGAAS 1.95 ~ 2.5 μm The minimum temperature+50 ℃: 3 ° C or less,
The minimum temperature+100 ° C less than 100 ° C: 1 ° C or less,
Minimum temperature+100 ° C or higher: 0.5 ° C or less
Reset method-
Time: 0.01 ~ 10 seconds variable discharge: Time 0.01 ~ 10 seconds, level 0.2 ~ 1.0
DC4.7 ~ 27V, 0.1a Max Output swing width: about ± 4V,
Communication speed: 4,800 9,600 19,200 38,400 57,600 115,200bps
Warranty range 0.3 ~ 1.0 Set range 0.050 ~ 1.000 (Settings decomposition No 0.001) ± 0.2% ± 2 ℃ of the measured value The minimum temperature+50 ℃: 3 ° C or less,
The minimum temperature+100 ° C less than 100 ° C: 1 ° C or less,
Minimum temperature+100 ° C or higher: 0.5 ° C or less
-15 ~ 70 ° C Span: 0.500 ~ 2,000, zero: -50 ~+50 ° C (° f) none 180 to 2,000 ° C 0 to 50 ℃ 1 minute Excludes dustproof (equivalent to IP67) and e-conf connectors
Fiber type radiation thermometer FTKX series-Part Number-FTKX-TNE0240

FTKX-TNE0240

Available upon quote Less than 800 ° C: ± 4 ℃,
800 to 1,200 ° C: ± 0.5%of measured values,
1,200 super ~ 2,000 ° C: ± 1.0% of measured values
Green LED aim Orbund train 1 point DC 27V, 0.2A,
Hysteresis setting width: 0 ~ 99.9 ℃
30-85%RH (without condensation) INGAAS 1.95 ~ 2.5 μm The minimum temperature+50 ℃: 3 ° C or less,
The minimum temperature+100 ° C less than 100 ° C: 1 ° C or less,
Minimum temperature+100 ° C or higher: 0.5 ° C or less
Reset method-
Time: 0.01 ~ 10 seconds variable discharge: Time 0.01 ~ 10 seconds, level 0.2 ~ 1.0
DC4.7 ~ 27V, 0.1a Max Output swing width: about ± 4V,
Communication speed: 4,800 9,600 19,200 38,400 57,600 115,200bps
Warranty range 0.3 ~ 1.0 Set range 0.050 ~ 1.000 (Settings decomposition No 0.001) ± 0.2% ± 2 ℃ of the measured value The minimum temperature+50 ℃: 3 ° C or less,
The minimum temperature+100 ° C less than 100 ° C: 1 ° C or less,
Minimum temperature+100 ° C or higher: 0.5 ° C or less
-15 ~ 70 ° C Span: 0.500 ~ 2,000, zero: -50 ~+50 ° C (° f) none 240 to 2,000 ° C 0 to 50 ℃ 1 minute Excludes dustproof (equivalent to IP67) and e-conf connectors
Fiber type radiation thermometer FTKX series-Part Number-FTKX-PNE0220

FTKX-PNE0220

Available upon quote Less than 800 ° C: ± 4 ℃,
800 to 1,200 ° C: ± 0.5%of measured values,
1,200 super ~ 2,000 ° C: ± 1.0% of measured values
Green LED aim Orbund train 1 point DC 27V, 0.2A,
Hysteresis setting width: 0 ~ 99.9 ℃
30-85%RH (without condensation) INGAAS 0.8 ~ 1.6 μm The minimum temperature+50 ℃: 3 ° C or less,
The minimum temperature+100 ° C less than 100 ° C: 1 ° C or less,
Minimum temperature+100 ° C or higher: 0.5 ° C or less
Reset method-
Time: 0.01 ~ 10 seconds variable discharge: Time 0.01 ~ 10 seconds, level 0.2 ~ 1.0
DC4.7 ~ 27V, 0.1a Max Output swing width: about ± 4V,
Communication speed: 4,800 9,600 19,200 38,400 57,600 115,200bps
Warranty range 0.3 ~ 1.0 Set range 0.050 ~ 1.000 (Settings decomposition No 0.001) ± 0.2% ± 2 ℃ of the measured value The minimum temperature+50 ℃: 3 ° C or less,
The minimum temperature+100 ° C less than 100 ° C: 1 ° C or less,
Minimum temperature+100 ° C or higher: 0.5 ° C or less
-15 ~ 70 ° C Span: 0.500 ~ 2,000, zero: -50 ~+50 ° C (° f) none 220 ~ 1,650 ° C 0 to 50 ℃ 1 minute Excludes dustproof (equivalent to IP67) and e-conf connectors
Fiber type radiation thermometer FTKX series-Part Number-FTKX-PNE0300

FTKX-PNE0300

Available upon quote Less than 800 ° C: ± 4 ℃,
800 to 1,200 ° C: ± 0.5%of measured values,
1,200 super ~ 2,000 ° C: ± 1.0% of measured values
Green LED aim Orbund train 1 point DC 27V, 0.2A,
Hysteresis setting width: 0 ~ 99.9 ℃
30-85%RH (without condensation) INGAAS 0.8 ~ 1.6 μm The minimum temperature+50 ℃: 3 ° C or less,
The minimum temperature+100 ° C less than 100 ° C: 1 ° C or less,
Minimum temperature+100 ° C or higher: 0.5 ° C or less
Reset method-
Time: 0.01 ~ 10 seconds variable discharge: Time 0.01 ~ 10 seconds, level 0.2 ~ 1.0
DC4.7 ~ 27V, 0.1a Max Output swing width: about ± 4V,
Communication speed: 4,800 9,600 19,200 38,400 57,600 115,200bps
Warranty range 0.3 ~ 1.0 Set range 0.050 ~ 1.000 (Settings decomposition No 0.001) ± 0.2% ± 2 ℃ of the measured value The minimum temperature+50 ℃: 3 ° C or less,
The minimum temperature+100 ° C less than 100 ° C: 1 ° C or less,
Minimum temperature+100 ° C or higher: 0.5 ° C or less
-15 ~ 70 ° C Span: 0.500 ~ 2,000, zero: -50 ~+50 ° C (° f) none 300 ~ 2,000 ° C 0 to 50 ℃ 1 minute Excludes dustproof (equivalent to IP67) and e-conf connectors
Fiber type radiation thermometer FTKX series-Part Number-FTKX-PNE0400

FTKX-PNE0400

Available upon quote Less than 800 ° C: ± 4 ℃,
800 to 1,200 ° C: ± 0.5%of measured values,
1,200 super ~ 2,000 ° C: ± 1.0% of measured values
Green LED aim Orbund train 1 point DC 27V, 0.2A,
Hysteresis setting width: 0 ~ 99.9 ℃
30-85%RH (without condensation) INGAAS 0.8 ~ 1.6 μm The minimum temperature+50 ℃: 3 ° C or less,
The minimum temperature+100 ° C less than 100 ° C: 1 ° C or less,
Minimum temperature+100 ° C or higher: 0.5 ° C or less
Reset method-
Time: 0.01 ~ 10 seconds variable discharge: Time 0.01 ~ 10 seconds, level 0.2 ~ 1.0
DC4.7 ~ 27V, 0.1a Max Output swing width: about ± 4V,
Communication speed: 4,800 9,600 19,200 38,400 57,600 115,200bps
Warranty range 0.3 ~ 1.0 Set range 0.050 ~ 1.000 (Settings decomposition No 0.001) ± 0.2% ± 2 ℃ of the measured value The minimum temperature+50 ℃: 3 ° C or less,
The minimum temperature+100 ° C less than 100 ° C: 1 ° C or less,
Minimum temperature+100 ° C or higher: 0.5 ° C or less
-15 ~ 70 ° C Span: 0.500 ~ 2,000, zero: -50 ~+50 ° C (° f) none 400 to 2,000 ° C 0 to 50 ℃ 1 minute Excludes dustproof (equivalent to IP67) and e-conf connectors
Fiber type radiation thermometer FTKX series-Part Number-FTKX-ANE0500

FTKX-ANE0500

Available upon quote Less than 800 ° C: ± 4 ℃,
800 to 1,200 ° C: ± 0.5%of measured values,
1,200 super ~ 2,000 ° C: ± 1.0% of measured values
Green LED aim Orbund train 1 point DC 27V, 0.2A,
Hysteresis setting width: 0 ~ 99.9 ℃
30-85%RH (without condensation) Si 0.8 ~ 1.0 μm The minimum temperature+50 ℃: 3 ° C or less,
The minimum temperature+100 ° C less than 100 ° C: 1 ° C or less,
Minimum temperature+100 ° C or higher: 0.5 ° C or less
Reset method-
Time: 0.01 ~ 10 seconds variable discharge: Time 0.01 ~ 10 seconds, level 0.2 ~ 1.0
DC4.7 ~ 27V, 0.1a Max Output swing width: about ± 4V,
Communication speed: 4,800 9,600 19,200 38,400 57,600 115,200bps
Warranty range 0.3 ~ 1.0 Set range 0.050 ~ 1.000 (Settings decomposition No 0.001) ± 0.2% ± 2 ℃ of the measured value The minimum temperature+50 ℃: 3 ° C or less,
The minimum temperature+100 ° C less than 100 ° C: 1 ° C or less,
Minimum temperature+100 ° C or higher: 0.5 ° C or less
-15 ~ 70 ° C Span: 0.500 ~ 2,000, zero: -50 ~+50 ° C (° f) none 500 to 2,000 ° C 0 to 50 ℃ 1 minute Excludes dustproof (equivalent to IP67) and e-conf connectors
Fiber type radiation thermometer FTKX series-Part Number-FTKX-ANE0600

FTKX-ANE0600

Available upon quote Less than 800 ° C: ± 4 ℃,
800 to 1,200 ° C: ± 0.5%of measured values,
1,200 super ~ 2,000 ° C: ± 1.0% of measured values
Green LED aim Orbund train 1 point DC 27V, 0.2A,
Hysteresis setting width: 0 ~ 99.9 ℃
30-85%RH (without condensation) Si 0.8 ~ 1.0 μm The minimum temperature+50 ℃: 3 ° C or less,
The minimum temperature+100 ° C less than 100 ° C: 1 ° C or less,
Minimum temperature+100 ° C or higher: 0.5 ° C or less
Reset method-
Time: 0.01 ~ 10 seconds variable discharge: Time 0.01 ~ 10 seconds, level 0.2 ~ 1.0
DC4.7 ~ 27V, 0.1a Max Output swing width: about ± 4V,
Communication speed: 4,800 9,600 19,200 38,400 57,600 115,200bps
Warranty range 0.3 ~ 1.0 Set range 0.050 ~ 1.000 (Settings decomposition No 0.001) ± 0.2% ± 2 ℃ of the measured value The minimum temperature+50 ℃: 3 ° C or less,
The minimum temperature+100 ° C less than 100 ° C: 1 ° C or less,
Minimum temperature+100 ° C or higher: 0.5 ° C or less
-15 ~ 70 ° C Span: 0.500 ~ 2,000, zero: -50 ~+50 ° C (° f) none 600 to 2,000 ° C 0 to 50 ℃ 1 minute Excludes dustproof (equivalent to IP67) and e-conf connectors
Fiber type radiation thermometer FTKX series-Part Number-FTKX-ANE0700

FTKX-ANE0700

Available upon quote Less than 800 ° C: ± 4 ℃,
800 to 1,200 ° C: ± 0.5%of measured values,
1,200 super ~ 2,000 ° C: ± 1.0% of measured values
Green LED aim Orbund train 1 point DC 27V, 0.2A,
Hysteresis setting width: 0 ~ 99.9 ℃
30-85%RH (without condensation) Si 0.8 ~ 1.0 μm The minimum temperature+50 ℃: 3 ° C or less,
The minimum temperature+100 ° C less than 100 ° C: 1 ° C or less,
Minimum temperature+100 ° C or higher: 0.5 ° C or less
Reset method-
Time: 0.01 ~ 10 seconds variable discharge: Time 0.01 ~ 10 seconds, level 0.2 ~ 1.0
DC4.7 ~ 27V, 0.1a Max Output swing width: about ± 4V,
Communication speed: 4,800 9,600 19,200 38,400 57,600 115,200bps
Warranty range 0.3 ~ 1.0 Set range 0.050 ~ 1.000 (Settings decomposition No 0.001) ± 0.2% ± 2 ℃ of the measured value The minimum temperature+50 ℃: 3 ° C or less,
The minimum temperature+100 ° C less than 100 ° C: 1 ° C or less,
Minimum temperature+100 ° C or higher: 0.5 ° C or less
-15 ~ 70 ° C Span: 0.500 ~ 2,000, zero: -50 ~+50 ° C (° f) none 700 to 2,000 ° C 0 to 50 ℃ 1 minute Excludes dustproof (equivalent to IP67) and e-conf connectors

Click on the part number for more information about each product

Customers who viewed this product also viewed

Other products of Japan Sensor


View more products of Japan Sensor

About Company Handling This Product

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree