Fiberless type radiation thermometer FLHX series-FLHX-TNE0090
Fiberless type radiation thermometer FLHX series-Japan Sensor

Fiberless type radiation thermometer FLHX series
Japan Sensor


About This Product

The FLHX series is a fibrace -type radiation thermometer that allows you to select the temperature range, measurement distance, target size, etc. like a semi -order. The world's highest class response speed is 0.001 seconds, and the transportation is surely measured. You can also measure the temperature inside the tank through the window. ■ Radiation thermometer that can change the specifications according to the measured object The FLHX series is a fibrace -type radiation thermometer that allows you to select the temperature range, measurement distance, target size, etc. like a semi -order. ・ Radiation thermometer that can change the specifications according to the measured object ・ Because it is a fibrace, it is reasonable ・ Temperature measurement range of abundant variations of 90 ° C to 2000 ° C (9 types) (custom -made can also support more than 2000 ° C) ・ Φ0.15mm ~ You can also aim small work ・ Surely measure temperature with the world's highest class high -speed response 1ms (0.001s) ・ Measurement through windows can be measured ・ Green LED is easier to see than before and easy to adjust ・ Challenge the bad environment with a sturdy body ・ Equipped with both analog output and RS232C output ・ CE marking compatible product. * CE marking conformity is only LED aiming specification. * The instruction manual can be downloaded in the Japanese version and English version. * The display setting device is sold separately. * The specifications may be changed by the release date. Please understand. ■ Radiation thermometer that can change the specifications according to the measured object The temperature range, measurement distance, target size, etc. can be selected from 140 or more specifications according to the measured object, so more advanced temperature measurement is possible. ■ Reasonable because it is a fibrace Because it is a fiberly type, it is offered at a reasonable price. When introducing a radiation thermometer for the first time, it is ideal for introducing it to the line. ■ A wide variety of temperature measurement range A wide variety of temperature measurement range of 90 ° C to 2000 ° C (9 types) (custom -made can be used for over 2000 ° C) ■ You can also aim small work Target size φ0.15mm ~. The optical system has been reviewed and smaller spots can be measured. ■ World's highest class high -speed response 1ms (0.001s) The world's highest -class high -speed response 1ms (0.001s) will not overlook the sudden temperature change. ■ Temperature measurement through quartz glass is possible In the case of a thermometer using a long wavelength with a measurement wavelength of about 10 μm, the temperature of the quartz glass itself is measured. The FLHX series uses a short wave length (0.8 to 2.6 μm) to transmit up to 90%of quartz glass. The temperature in the vacuum tank can be measured through the window. ■ Easy positioning The "optical axis LED aiming method" used by the FLHX series can be easily aligned because the temperature measurement range is close to the eye. In addition, it is easier to adjust the position even in the red part at high temperature by adopting a green LED. It is possible to aim LED even during temperature measurement. ■ Challenge the bad environment with a sturdy body By adopting an aluminum body, robustness, durability, and drug resistance are improved. Dustproof structure equivalent to IP67. Since it is a symmetrical design, it is easier to install. ■ Equipped with both analog output and RS232C output Analog output 1 point: 4-20ma, 0 ~ 20ma, 0-1v, MV/℃ switch.

  • Product

    Fiberless type radiation thermometer FLHX series




*Please note that we may not be able to accommodate sample requests.

9 Models of Fiberless type radiation thermometer FLHX series

Items marked with have different values ​​depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Accuracy rating Aim Alarm output Approximately used humidity Detector Effective wavelength Material Measurement and decomposition ability Peak hold Power-supply voltage RS232C output Radioactivity correction Reproducibility Response time Save surrounding temperature Sensor correction function Temperature display Temperature range Used peripheral temperature Warm -up time structure
Fiberless type radiation thermometer FLHX series-Part Number-FLHX-TNE0090

FLHX-TNE0090

Available upon quote Less than 800 ° C: ± 4 ℃
800 ~ 1,200 ° C: ± 0.5% of measured values
1,200 super ~ 2,000 ° C: ± 1.0% of measured values
Green LED aim Orbund train 1 point DC 27V, 0.2a,
Hysteresis setting width: 0 ~ 99.9 ℃
30-85%RH (without condensation) INGAAS 1.95 ~ 2.6 μm Aluminum (black alumite) Lowest temperature+50 ° C: 3 ° C or less,
The minimum temperature+100 ° C: 1 ° C or less,
The minimum temperature+100 ° C or higher: 0.5 ° C or less,
Reset method,
Time: 0.01 ~ 10 seconds variable discharge: Time 0.01 ~ 10 seconds, level 0.2 ~ 1.0
DC4.7 ~ 27V, 0.1a Max Output swing width: about ± 4V,
Communication speed: 4,800 9,600 19,200 38,400 57,600 115,200bps
Warranty range 0.3 ~ 1.0 Set range 0.050 ~ 1.000 (Settings decomposition No 0.001) ± 0.2% ± 2 ℃ of the measured value In the case of analog output: 0.001 ~ 5 seconds (0 to 95%analog output) variable setting with smoothing function -15 ~ 70 ° C Span: 0.500 ~ 2,000, zero: -50 ~+50 ° C (° f) none 90-1,500 ° C 0 to 50 ℃ 1 minute Excludes dustproof (equivalent to IP67) and e-conf connectors
Fiberless type radiation thermometer FLHX series-Part Number-FLHX-TNE0160

FLHX-TNE0160

Available upon quote Less than 800 ° C: ± 4 ℃
800 ~ 1,200 ° C: ± 0.5% of measured values
1,200 super ~ 2,000 ° C: ± 1.0% of measured values
Green LED aim Orbund train 1 point DC 27V, 0.2a,
Hysteresis setting width: 0 ~ 99.9 ℃
30-85%RH (without condensation) INGAAS 1.95 ~ 2.6 μm Aluminum (black alumite) Lowest temperature+50 ° C: 3 ° C or less,
The minimum temperature+100 ° C: 1 ° C or less,
Minimum temperature+100 ° C or higher: 0.5 ° C or less
Reset method,
Time: 0.01 ~ 10 seconds variable discharge: Time 0.01 ~ 10 seconds, level 0.2 ~ 1.0
DC4.7 ~ 27V, 0.1a Max Output swing width: about ± 4V,
Communication speed: 4,800 9,600 19,200 38,400 57,600 115,200bps
Warranty range 0.3 ~ 1.0 Set range 0.050 ~ 1.000 (Settings decomposition No 0.001) ± 0.2% ± 2 ℃ of the measured value In the case of analog output: 0.001 ~ 5 seconds (0 to 95%analog output) variable setting with smoothing function -15 ~ 70 ° C Span: 0.500 ~ 2,000, zero: -50 ~+50 ° C (° f) none 160 to 2,000 ° C 0 to 50 ℃ 1 minute Excludes dustproof (equivalent to IP67) and e-conf connectors
Fiberless type radiation thermometer FLHX series-Part Number-FLHX-TNE0220

FLHX-TNE0220

Available upon quote Less than 800 ° C: ± 4 ℃
800 ~ 1,200 ° C: ± 0.5% of measured values
1,200 super ~ 2,000 ° C: ± 1.0% of measured values
Green LED aim Orbund train 1 point DC 27V, 0.2a,
Hysteresis setting width: 0 ~ 99.9 ℃
30-85%RH (without condensation) INGAAS 1.95 ~ 2.6 μm Aluminum (black alumite) Lowest temperature+50 ° C: 3 ° C or less,
The minimum temperature+100 ° C: 1 ° C or less,
Minimum temperature+100 ° C or higher: 0.5 ° C or less
Reset method,
Time: 0.01 ~ 10 seconds variable discharge: Time 0.01 ~ 10 seconds, level 0.2 ~ 1.0
DC4.7 ~ 27V, 0.1a Max Output swing width: about ± 4V,
Communication speed: 4,800 9,600 19,200 38,400 57,600 115,200bps
Warranty range 0.3 ~ 1.0 Set range 0.050 ~ 1.000 (Settings decomposition No 0.001) ± 0.2% ± 2 ℃ of the measured value In the case of analog output: 0.001 ~ 5 seconds (0 to 95%analog output) variable setting with smoothing function -15 ~ 70 ° C Span: 0.500 ~ 2,000, zero: -50 ~+50 ° C (° f) none 220 ~ 2,000 ° C 0 to 50 ℃ 1 minute Excludes dustproof (equivalent to IP67) and e-conf connectors
Fiberless type radiation thermometer FLHX series-Part Number-FLHX-PNE0220

FLHX-PNE0220

Available upon quote Less than 800 ° C: ± 4 ℃
800 ~ 1,200 ° C: ± 0.5% of measured values
1,200 super ~ 2,000 ° C: ± 1.0% of measured values
Green LED aim Orbund train 1 point DC 27V, 0.2a,
Hysteresis setting width: 0 ~ 99.9 ℃
30-85%RH (without condensation) INGAAS 0.8 ~ 1.6 μm Aluminum (black alumite) Lowest temperature+50 ° C: 3 ° C or less,
The minimum temperature+100 ° C: 1 ° C or less,
Minimum temperature+100 ° C or higher: 0.5 ° C or less
Reset method,
Time: 0.01 ~ 10 seconds variable discharge: Time 0.01 ~ 10 seconds, level 0.2 ~ 1.0
DC4.7 ~ 27V, 0.1a Max Output swing width: about ± 4V,
Communication speed: 4,800 9,600 19,200 38,400 57,600 115,200bps
Warranty range 0.3 ~ 1.0 Set range 0.050 ~ 1.000 (Settings decomposition No 0.001) ± 0.2% ± 2 ℃ of the measured value In the case of analog output: 0.001 ~ 5 seconds (0 to 95%analog output) variable setting with smoothing function -15 ~ 70 ° C Span: 0.500 ~ 2,000, zero: -50 ~+50 ° C (° f) none 220 ~ 1,650 ° C 0 to 70 ° C 1 minute Excludes dustproof (equivalent to IP67) and e-conf connectors
Fiberless type radiation thermometer FLHX series-Part Number-FLHX-PNE0300

FLHX-PNE0300

Available upon quote Less than 800 ° C: ± 4 ℃
800 ~ 1,200 ° C: ± 0.5% of measured values
1,200 super ~ 2,000 ° C: ± 1.0% of measured values
Green LED aim Orbund train 1 point DC 27V, 0.2a,
Hysteresis setting width: 0 ~ 99.9 ℃
30-85%RH (without condensation) INGAAS 0.8 ~ 1.6 μm Aluminum (black alumite) Lowest temperature+50 ° C: 3 ° C or less,
The minimum temperature+100 ° C: 1 ° C or less,
Minimum temperature+100 ° C or higher: 0.5 ° C or less
Reset method,
Time: 0.01 ~ 10 seconds variable discharge: Time 0.01 ~ 10 seconds, level 0.2 ~ 1.0
DC4.7 ~ 27V, 0.1a Max Output swing width: about ± 4V,
Communication speed: 4,800 9,600 19,200 38,400 57,600 115,200bps
Warranty range 0.3 ~ 1.0 Set range 0.050 ~ 1.000 (Settings decomposition No 0.001) ± 0.2% ± 2 ℃ of the measured value In the case of analog output: 0.001 ~ 5 seconds (0 to 95%analog output) variable setting with smoothing function -15 ~ 70 ° C Span: 0.500 ~ 2,000, zero: -50 ~+50 ° C (° f) none 300 ~ 2,000 ° C 0 to 70 ° C 1 minute Excludes dustproof (equivalent to IP67) and e-conf connectors
Fiberless type radiation thermometer FLHX series-Part Number-FLHX-PNE0400

FLHX-PNE0400

Available upon quote Less than 800 ° C: ± 4 ℃
800 ~ 1,200 ° C: ± 0.5% of measured values
1,200 super ~ 2,000 ° C: ± 1.0% of measured values
Green LED aim Orbund train 1 point DC 27V, 0.2a,
Hysteresis setting width: 0 ~ 99.9 ℃
30-85%RH (without condensation) INGAAS 0.8 ~ 1.6 μm Aluminum (black alumite) Lowest temperature+50 ° C: 3 ° C or less,
The minimum temperature+100 ° C: 1 ° C or less,
Minimum temperature+100 ° C or higher: 0.5 ° C or less
Reset method,
Time: 0.01 ~ 10 seconds variable discharge: Time 0.01 ~ 10 seconds, level 0.2 ~ 1.0
DC4.7 ~ 27V, 0.1a Max Output swing width: about ± 4V,
Communication speed: 4,800 9,600 19,200 38,400 57,600 115,200bps
Warranty range 0.3 ~ 1.0 Set range 0.050 ~ 1.000 (Settings decomposition No 0.001) ± 0.2% ± 2 ℃ of the measured value In the case of analog output: 0.001 ~ 5 seconds (0 to 95%analog output) variable setting with smoothing function -15 ~ 70 ° C Span: 0.500 ~ 2,000, zero: -50 ~+50 ° C (° f) none 400 to 2,000 ° C 0 to 70 ° C 1 minute Excludes dustproof (equivalent to IP67) and e-conf connectors
Fiberless type radiation thermometer FLHX series-Part Number-FLHX-ANE0500

FLHX-ANE0500

Available upon quote Less than 800 ° C: ± 4 ℃
800 ~ 1,200 ° C: ± 0.5% of measured values
1,200 super ~ 2,000 ° C: ± 1.0% of measured values
Green LED aim Orbund train 1 point DC 27V, 0.2a,
Hysteresis setting width: 0 ~ 99.9 ℃
30-85%RH (without condensation) Si 0.8 ~ 1.0 μm Aluminum (black alumite) Lowest temperature+50 ° C: 3 ° C or less,
The minimum temperature+100 ° C: 1 ° C or less,
Minimum temperature+100 ° C or higher: 0.5 ° C or less
Reset method,
Time: 0.01 ~ 10 seconds variable discharge: Time 0.01 ~ 10 seconds, level 0.2 ~ 1.0
DC4.7 ~ 27V, 0.1a Max Output swing width: about ± 4V,
Communication speed: 4,800 9,600 19,200 38,400 57,600 115,200bps
Warranty range 0.3 ~ 1.0 Set range 0.050 ~ 1.000 (Settings decomposition No 0.001) ± 0.2% ± 2 ℃ of the measured value In the case of analog output: 0.001 ~ 5 seconds (0 to 95%analog output) variable setting with smoothing function -15 ~ 70 ° C Span: 0.500 ~ 2,000, zero: -50 ~+50 ° C (° f) none 500 to 2,000 ° C 0 to 70 ° C 1 minute Excludes dustproof (equivalent to IP67) and e-conf connectors
Fiberless type radiation thermometer FLHX series-Part Number-FLHX-ANE0600

FLHX-ANE0600

Available upon quote Less than 800 ° C: ± 4 ℃
800 ~ 1,200 ° C: ± 0.5% of measured values
1,200 super ~ 2,000 ° C: ± 1.0% of measured values
Green LED aim Orbund train 1 point DC 27V, 0.2a,
Hysteresis setting width: 0 ~ 99.9 ℃
30-85%RH (without condensation) Si 0.8 ~ 1.0 μm Aluminum (black alumite) Lowest temperature+50 ° C: 3 ° C or less,
The minimum temperature+100 ° C: 1 ° C or less,
Minimum temperature+100 ° C or higher: 0.5 ° C or less
Reset method,
Time: 0.01 ~ 10 seconds variable discharge: Time 0.01 ~ 10 seconds, level 0.2 ~ 1.0
DC4.7 ~ 27V, 0.1a Max Output swing width: about ± 4V,
Communication speed: 4,800 9,600 19,200 38,400 57,600 115,200bps
Warranty range 0.3 ~ 1.0 Set range 0.050 ~ 1.000 (Settings decomposition No 0.001) ± 0.2% ± 2 ℃ of the measured value In the case of analog output: 0.001 ~ 5 seconds (0 to 95%analog output) variable setting with smoothing function -15 ~ 70 ° C Span: 0.500 ~ 2,000, zero: -50 ~+50 ° C (° f) none 600 to 2,000 ° C 0 to 70 ° C 1 minute Excludes dustproof (equivalent to IP67) and e-conf connectors
Fiberless type radiation thermometer FLHX series-Part Number-FLHX-ANE0700

FLHX-ANE0700

Available upon quote Less than 800 ° C: ± 4 ℃
800 ~ 1,200 ° C: ± 0.5% of measured values
1,200 super ~ 2,000 ° C: ± 1.0% of measured values
Green LED aim Orbund train 1 point DC 27V, 0.2a,
Hysteresis setting width: 0 ~ 99.9 ℃
30-85%RH (without condensation) Si 0.8 ~ 1.0 μm Aluminum (black alumite) Lowest temperature+50 ° C: 3 ° C or less,
The minimum temperature+100 ° C: 1 ° C or less,
Minimum temperature+100 ° C or higher: 0.5 ° C or less
Reset method,
Time: 0.01 ~ 10 seconds variable discharge: Time 0.01 ~ 10 seconds, level 0.2 ~ 1.0
DC4.7 ~ 27V, 0.1a Max Output swing width: about ± 4V,
Communication speed: 4,800 9,600 19,200 38,400 57,600 115,200bps
Warranty range 0.3 ~ 1.0 Set range 0.050 ~ 1.000 (Settings decomposition No 0.001) ± 0.2% ± 2 ℃ of the measured value In the case of analog output: 0.001 ~ 5 seconds (0 to 95%analog output) variable setting with smoothing function -15 ~ 70 ° C Span: 0.500 ~ 2,000, zero: -50 ~+50 ° C (° f) none 700 to 2,000 ° C 0 to 70 ° C 1 minute Excludes dustproof (equivalent to IP67) and e-conf connectors

Click on the part number for more information about each product

Customers who viewed this product also viewed

Other products of Japan Sensor


View more products of Japan Sensor

About Company Handling This Product

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree