2 -colored radiation thermometer general -purpose series METIS M311 / M322Handling Company
Japan SensorCategories
Click on the part number for more information about each product
Image | Part Number | Price (excluding tax) | Temperature range | Temperature sublerange | Spectrum range | Detector | Response time T90 | Exposure time | Uncertainty | Reproducibility | Temperature coefficient | 2 Analog output | Serial communication | Input Output | ProFibus | ProFinet | Display (12 -pin device only) | Device parameter | Need for power | isolation | Visual Organization (selection) | Ambient temperature | Relative temperature | Housing / Protection grade | Weight | CE Label |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
M311 |
Available upon quote |
650-1,400 ° C, |
Any temperature subrage that can be adjusted in the temperature range (minimum span 50 ° C) |
Channel 1: 0.93-1.1 μm / Channel 2: 0.75-0.93 μm, |
2 × SILICON |
<1ms (dynamic adaptation at a low traffic light, can be adjusted up to 10 seconds |
<0.5ms |
Full scale temperature ≦ 2,500 ° C: 0.3% (℃+2k at the measured temperature), |
0.1% (℃+1k at the measurement temperature) |
Deviation from 23 ° C: 0.04%/k; from 10 ° C to 60 ° C; 0.06%/k K; 0 ° C to 10 ° C and 60 ° C to 80 ° C |
0 or 4-20mA, maximum load. 500Ω, resolution 0.0015% (adjusted) temperature (sub) range (16 bits), |
RS232 (4.8-115.2 kbd) or RS485 (4.8-921.6 KBD), switchable, decomposition No |
12 Pin Connector: 3 composed connector digital input, output or analog input, |
12 Pind Vise Options: IEC61158 Type 3 supports Profibus DP-V0 (and DP-V1) |
12 Pind Vise Options: Supports Profinet-RT and IRT compliant with specifications 2.3. |
Dot matrix, green and yellow, 128 × 32 dots (height 5.6mm), for temperature or parameter settings, decomposition performance 0.1 ° C/° f |
Temperature measurement of two or one color, temperature subrage. Response time, radiation ratio gradient, radiation rate, transparency, spot size filfactor, peak picker, device address, borate, analog output, interface, temperature unit, device menu, focus distance |
23V DC (18-30V DC), Max.6 Va; Reverse polarity protection |
Voltage supply, analog output, and serial interfaces are electrically insulated. |
・ Aim through the lens |
0 to 80 ° C, optical side of optical fiber devices: -20 to 250 ° C, |
Conditions without condensation |
With aluminum/IP65, din40 050 connector |
650g |
According to the EU command of electromagnetic immunity |
|
M322 |
Available upon quote |
250-1,000 ° C, |
Any temperature subrage that can be adjusted in the temperature range (minimum span 50 ° C) |
Channel 1: 1.65-1.8 μm / Channel 2: 1.45-1.65 μm, |
2 × INGAAS |
<1ms (dynamic adaptation at a low traffic light, can be adjusted up to 10 seconds |
<0.5ms |
0.5% (℃+2k at the measurement temperature) |
0.1% (℃+1k at the measurement temperature) |
Deviation from 23 ° C: 0.04%/k; from 10 ° C to 60 ° C; 0.06%/k K; 0 ° C to 10 ° C and 60 ° C to 80 ° C |
0 or 4-20mA, maximum load. 500Ω, resolution 0.0015% (adjusted) temperature (sub) range (16 bits), |
RS232 (4.8-115.2 kbd) or RS485 (4.8-921.6 KBD), switchable, decomposition No |
12 Pin Connector: 3 composed connector digital input, output or analog input, |
12 Pind Vise Options: IEC61158 Type 3 supports Profibus DP-V0 (and DP-V1) |
12 Pind Vise Options: Supports Profinet-RT and IRT compliant with specifications 2.3. |
Dot matrix, green and yellow, 128 × 32 dots (height 5.6mm), for temperature or parameter settings, decomposition performance 0.1 ° C/° f |
Temperature measurement of two or one color, temperature subrage. Response time, radiation ratio gradient, radiation rate, transparency, spot size filfactor, peak picker, device address, borate, analog output, interface, temperature unit, device menu, focus distance |
23V DC (18-30V DC), Max.6 Va; Reverse polarity protection |
Voltage supply, analog output, and serial interfaces are electrically insulated. |
・ Aim through the lens |
0 to 80 ° C, optical side of optical fiber devices: -20 to 250 ° C, |
Conditions without condensation |
With aluminum/IP65, din40 050 connector |
650g |
According to the EU command of electromagnetic immunity |