Product
Concentration meter Electromagnetic concentration controllerHandling Company
Cem Corporation Co., Ltd.Categories
Items marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | Accuracy | Alarm contact output | Change measurement target data | Conductivity range | Correction of measured values | Data to be measured | Display | External input | Measuring range | Operating environment | Power consumption | Power supply | Protective structure | Pulse output | Resolution | Size | Standard accessories | Transmission output | Voltage output | Weight |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cm-81 |
Available upon quote | F.S within ±0.5% (conductivity measurement value) *Repeat error due to pseudo signal |
2 points Control method: ON/OFF control Hysteresis width 0.01%~F.S Contact capacity AC240V1A or less (resistive load) |
Select from 4 types of liquid with touch switch Regarding DATA5 (any liquid), 8 coefficients can be changed with a touch switch |
0~1000mS/cm 0~300mS/cm 0~30mS/cm |
Measured value shift (shift width -1.00%~+1.00%) |
DATA1 Sodium chloride 0~20% DATA2 Hydrochloric acid 0~15% DATA3 Sulfuric acid 0~25% DATA4 Sodium hydroxide 0~10% DATA5 Arbitrary data |
Digital LCD touch panel allows you to adjust the brightness of the backlight LED |
1 point no-voltage contact signal In the case of ON (short circuit), the control output selected as ON on the interlock setting screen is interlocked and turned OFF on the interlock setting screen. Selected control output operates normally. If OFF (open), normal control. |
- | 0~40℃ within 85%RH | 10VA (at no load) | AC100~240V 50/60pHz | Drip-proof structure equivalent to IP54 (when using sunshade cover) | Control method: Pulse proportional control (open collector) | Concentration 0.01% Temperature 0.1℃ Conductivity 0.1mS/cm | 138 (W) × 138 (H) × 174 (D) mm | Sunshade cover | DC4~20mA Input/output isolation Maximum connected load resistance 500Ω |
Control method: ON/OFF control Hysteresis width 0.01%~F.S 1 point upper/lower limit alarm output (voltage output): Outputs power supply voltage) Motor load current 0.5A (AC200V) / 1.0A (AC100V) |
Approximately 2kg | |
Cm-81S |
Available upon quote | - |
2 points Control method: ON/OFF control Hysteresis width 0.01%~F.S Contact capacity AC240V1A or less (resistive load) |
- | - | Measured value shift (shift width -1.00%~+1.00%) | - | The brightness of the backlight LED can be adjusted using the digital LCD touch panel. |
1 point no-voltage contact signal When ON, the control output selected as ON on the interlock setting screen is Control outputs selected as OFF on the interlock setting screen operate normally. When OFF, normal control. |
0.10~20.00% | 0~40℃ within 85%RH | 10VA (at no load) | AC100~240V 50/60pHz | Drip-proof structure equivalent to IP54 (when using sunshade cover) | Control method: Pulse proportional control (open collector) | Salinity: 0.01% Temperature: 0.1℃ | 138 (W) × 138 (H) × 174 (D) mm | Sunshade cover | DC4~20mA Input/output isolation Maximum connected load resistance 500Ω |
Control method: ON/OFF control Hysteresis width 0.01%~F.S 1 point upper/lower limit alarm output (voltage output): Outputs power supply voltage) Motor load current 0.5A (AC200V) / 1.0A (AC100V) |
Approximately 2kg |
Click on the part number for more information about each product