Near infrared analysis device for body measurement near infrared division light analyzer-A8860
Near infrared analysis device for body measurement near infrared division light analyzer-Nireco

Near infrared analysis device for body measurement near infrared division light analyzer
Nireco


About This Product

It is a nearby infrared model developed by its own company. Based on the accumulated technologies of near -infrared division light cultivated for more than 40 years, it is a near -infrared spectroscope analyzer in pursuit of the functions necessary for analysis in the test room. Various mechanisms, including sampling systems that meet various measurement requests on site, provide high cost performance and the world's highest class performance. It is used as a spectroscopy method, and it is possible to measure high-quality spectrum in the wavelength area of ​​400-2500 nm by a monochrome-compatible monochrome meter compatible with wide scanning. Sample temperature adjustment up to 60 ° C can be adjusted for each cell in the device, and the autosunpla mechanism can perform the standard two consecutive samples continuously. Liquid measurement near infrared division light analyzer (400-2500NM) model: A8860 detail of function ・ By installing the auto sampler function, it is possible to automatically measure the double liquid samples as standard. Autosunpla function ・ Temple temperature control Sample temperature control ・ Equipped with a temperature control mechanism up to 60 ° C in the device for each sample filled with cells, an automatic measurement function linked, and can be automatically measured after temperature control. This releases the analysts from the time -consuming sampling of the time -consuming sampling. Sampling accessories ・ Low volatile samples are open type that is not sealed, and highly volatile samples such as gasoline can be selected for closed screw top cubet cells. For manufacturing sites, you can use disposable disposable disposable disposable discounts and floorselellels that can be measured while circulating liquids. Cubet cells and frostlucells can be selected by the optimal lightway length for the samples and ingredients you want to analyze.

  • Product

    Near infrared analysis device for body measurement near infrared division light analyzer




*Please note that we may not be able to accommodate sample requests.

1 Models of Near infrared analysis device for body measurement near infrared division light analyzer

Product Image Part Number Price (excluding tax) Body dimensions Data interval Detector Input Power Measurement wavelength range Noise (RMS) AT0ABS Scales Scan speed mass power consumption
Near infrared analysis device for body measurement near infrared division light analyzer-Part Number-A8860

A8860

Available upon quote Width 406mm x height 394mm x depth 631mm 0.5nm 400-1100nmsi (silicon) 1100-2500NMPBS (lead sulfide) Single-phase AC100V-240V50/60Hz 400-2500NM 400-700nm <50μABS700-2500NM <30 μABS 2.0AU 2 scan/second 36kg Up to 200W

Other products of Nireco


View more products of Nireco

About Company Handling This Product

Nireco

  • Japan
  • Since 1950
  • 453 employees