This instrument is equipped with an intelligent function that can call various correction operations, range and various coefficients, set, change, self -diagnosis and loop check. Furthermore, from the communication, the settings and calls of each parameter can be performed in the smart communication unit (EL2310), and it is a smart vortex flow meter that allows you to communicate with higher -level computers. The sensor has a fixed form and a replacable form, and the replayable sensor can check and replace the sensor without stopping the flow of the line.

■ Main features

・ 2 -wire transmission can be achieved, planned cost reduction and system simplification. ・ Easy data setting ・ Excellent maintenance and can increase safety by reducing maintenance costs. ・ Maintenance work such as range settings, parameter settings, proofreading, etc. is possible while installed in the piping.

■ High performance and support for various applications

The combination of a whirlpool generated by a triangle cross section and a piezoelectric element sensor measure the flow rate of liquid, gas, and steam in high accuracy.

■ Easy to use and low cost

It has a durable and simple structure, easy to use and has excellent conservative, initial cost, running cost, total cost.

■ High safety

Structure with less fluids and few seals. In particular, the replayable sensor can maintain and check the sensor while attaching it to the piping without stopping the flow.

■ Energy saving / space saving

Energy -saving effect with small pressure loss, a dedicated rectification device can reduce the installation space.

  • Product

    The measurement system is freely configured with a wealth of lineup EX delta (standard, smart type)

Share this product


460+ people viewing

Last viewed: 12 seconds ago


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

8 Models of The measurement system is freely configured with a wealth of lineup EX delta (standard, smart type)

Click on the part number for more information about each product

Image Part Number Price (excluding tax) type Nominal diameter Flow -range liquid (water) Flow -up range gas (0.2MPa air) Flow -up range steam (0.5MPa saturated steam) Applicable fluid Operating temperature limit Flange standard Maximum use pressure accuracy power supply Body material structure output
The measurement system is freely configured with a wealth of lineup EX delta (standard, smart type)-Part Number-Vxu

Vxu

Available upon quote

Flange -type fixed sensor

15 ~ 300mm

0.2 * ~ 2,510m3/h (11 format) ( * The seal is 10mm and accuracy ± 2 % FS)

2 * ~ 15,000m3/h (11 format) ( * The seal is 10mm and accuracy ± 2 % FS)

0.02 ~ 47.6t/h (10 format) (15mm or more)

Liquid, gas, steam

-30 ~ + 300 ° C, -30 ~ + 460 ° C (for high temperature of replayable sensors)

JIS 10, 20, 30k ASME/JPI 150, 300, 600

4.51MPa (with flange standard and flange material)

± 1 % of the amount represented or ± 1 % of the full scale

DC power or battery drive

SUS316 or SCS14A

Explosion or non -explosion protection

Analog, pulse

The measurement system is freely configured with a wealth of lineup EX delta (standard, smart type)-Part Number-VXT

VXT

Available upon quote

Flange -shaped replesable sensor

15 ~ 300mm

0.2 * ~ 2,510m3/h (11 format) ( * The seal is 10mm and accuracy ± 2 % FS)

2 * ~ 15,000m3/h (11 format) ( * The seal is 10mm and accuracy ± 2 % FS)

0.02 ~ 47.6t/h (10 format) (15mm or more)

Liquid, gas, steam

-30 ~ + 300 ° C, -30 ~ + 460 ° C (for high temperature of replayable sensors)

JIS 10, 20, 30k ASME/JPI 150, 300, 601

4.51MPa (with flange standard and flange material)

± 1 % of the amount represented or ± 1 % of the full scale

DC power or battery drive

SUS316 or SCS14A

Explosion or non -explosion protection

Analog, pulse

The measurement system is freely configured with a wealth of lineup EX delta (standard, smart type)-Part Number-VXW

VXW

Available upon quote

Wafer -shaped fixing sensor (nominal diameter 10-150mm)

10 ~ 150mm (15mm or more for steam)

0.2 * ~ 2,510m3/h (11 format) ( * The seal is 10mm and accuracy ± 2 % FS)

2 * ~ 15,000m3/h (11 format) ( * The seal is 10mm and accuracy ± 2 % FS)

0.02 ~ 47.6t/h (10 format) (15mm or more)

Liquid, gas, steam

-30 ~ + 300 ° C, -30 ~ + 460 ° C (for high temperature of replayable sensors)

JIS 10, 20, 30k ASME/JPI 150, 300, 602

4.51MPa (with flange standard and flange material)

± 1 % of the amount represented or ± 1 % of the full scale

DC power or battery drive

SUS316 or SCS14A

Explosion or non -explosion protection

Analog, pulse

The measurement system is freely configured with a wealth of lineup EX delta (standard, smart type)-Part Number-VXF

VXF

Available upon quote

Flange -shaped fixed sensor (rhuan diameter 15mm or more, RF flange standard)

15 ~ 300mm

0.2 * ~ 2,510m3/h (11 format) ( * The seal is 10mm and accuracy ± 2 % FS)

2 * ~ 15,000m3/h (11 format) ( * The seal is 10mm and accuracy ± 2 % FS)

0.02 ~ 47.6t/h (10 format) (15mm or more)

Liquid, gas, steam

-30 ~ + 300 ° C, -30 ~ + 460 ° C (for high temperature of replayable sensors)

JIS 10, 20, 30k ASME/JPI 150, 300, 603

4.51MPa (with flange standard and flange material)

± 1 % of the amount represented or ± 1 % of the full scale

DC power or battery drive

SUS316 or SCS14A

Explosion or non -explosion protection

Analog, pulse

The measurement system is freely configured with a wealth of lineup EX delta (standard, smart type)-Part Number-VXR

VXR

Available upon quote

Flange -shaped replacables (RF flange standard, standard RF flange)

15 ~ 300mm

0.2 * ~ 2,510m3/h (11 format) ( * The seal is 10mm and accuracy ± 2 % FS)

2 * ~ 15,000m3/h (11 format) ( * The seal is 10mm and accuracy ± 2 % FS)

0.02 ~ 47.6t/h (10 format) (15mm or more)

Liquid, gas, steam

-30 ~ + 300 ° C, -30 ~ + 460 ° C (for high temperature of replayable sensors)

JIS 10, 20, 30k ASME/JPI 150, 300, 604

4.51MPa (with flange standard and flange material)

± 1 % of the amount represented or ± 1 % of the full scale

DC power or battery drive

SUS316 or SCS14A

Explosion or non -explosion protection

Analog, pulse

The measurement system is freely configured with a wealth of lineup EX delta (standard, smart type)-Part Number-VXJ

VXJ

Available upon quote

Rhinogata -shaped whirlpool -type wafer -shaped fixing sensor

10 ~ 150mm (15mm or more for steam)

0.2 * ~ 2,510m3/h (11 format) ( * The seal is 10mm and accuracy ± 2 % FS)

2 * ~ 15,000m3/h (11 format) ( * The seal is 10mm and accuracy ± 2 % FS)

0.02 ~ 47.6t/h (10 format) (15mm or more)

Liquid, gas, steam

-30 ~ + 300 ° C, -30 ~ + 460 ° C (for high temperature of replayable sensors)

JIS 10, 20, 30k ASME/JPI 150, 300, 605

4.51MPa (with flange standard and flange material)

± 1 % of the amount represented or ± 1 % of the full scale

DC power or battery drive

SUS316 or SCS14A

Explosion or non -explosion protection

Analog, pulse

The measurement system is freely configured with a wealth of lineup EX delta (standard, smart type)-Part Number-VXL

VXL

Available upon quote

Rhinodent whirlpool -type flange -type fixed sensor (order design)

15 ~ 300mm

0.2 * ~ 2,510m3/h (11 format) ( * The seal is 10mm and accuracy ± 2 % FS)

2 * ~ 15,000m3/h (11 format) ( * The seal is 10mm and accuracy ± 2 % FS)

0.02 ~ 47.6t/h (10 format) (15mm or more)

Liquid, gas, steam

-30 ~ + 300 ° C, -30 ~ + 460 ° C (for high temperature of replayable sensors)

JIS 10, 20, 30k ASME/JPI 150, 300, 606

4.51MPa (with flange standard and flange material)

± 1 % of the amount represented or ± 1 % of the full scale

DC power or battery drive

SUS316 or SCS14A

Explosion or non -explosion protection

Analog, pulse

The measurement system is freely configured with a wealth of lineup EX delta (standard, smart type)-Part Number-VXM

VXM

Available upon quote

Rhinodo -shaped vortex flange -type replayable sensor (order design)

15 ~ 300mm

0.2 * ~ 2,510m3/h (11 format) ( * The seal is 10mm and accuracy ± 2 % FS)

2 * ~ 15,000m3/h (11 format) ( * The seal is 10mm and accuracy ± 2 % FS)

0.02 ~ 47.6t/h (10 format) (15mm or more)

Liquid, gas, steam

-30 ~ + 300 ° C, -30 ~ + 460 ° C (for high temperature of replayable sensors)

JIS 10, 20, 30k ASME/JPI 150, 300, 607

4.51MPa (with flange standard and flange material)

± 1 % of the amount represented or ± 1 % of the full scale

DC power or battery drive

SUS316 or SCS14A

Explosion or non -explosion protection

Analog, pulse

Click on the part number for more information about each product

Customers who viewed this product also viewed

Reviews shown here are reviews of companies.

See More Flowmeters Products

Other products of OVAL Corporation

Reviews shown here are reviews of companies.


View more products of OVAL Corporation

About Company Handling This Product

Response Rate

100.0%


Response Time

23.1hrs

Company Overview

OVAL Corporation, founded in Tokyo, Japan, in 1949 is a manufacturer of metrological control equipment and rel...

See More

  • Japan

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree