Magnetic distortion linear sensor GY series that measures straight line displacement [Controller]Handling Company
SANTEST CO., LTDCategories
Click on the part number for more information about each product
Image | Part Number | Price (excluding tax) | resolution | Position output (OUT1) (OUT2: Option) | Speed output (OUT2) (optional) | Alarm output | Supply power supply | Bearing pressure | Sampling frequency | Temperature characteristics | Operating temperature limit | Save temperature range | Optional Accessories | Speed output (VEL) (optional) | Position output | Number of location detection axes | I/O occupied number | Internal power consumption | function | cable length |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
GYHC analog controller |
Available upon quote |
16bit (1/65,336) ( * 1), 0.01%or less ( * 2) |
0 ~ 10V (load current MAX.5mA, load resistance min.2kΩ) or 4 ~ 20mA (load resistance max.500Ω) |
± 10V or 4 ~ 20ma |
Open collector 0.1a 30VDC ( * 3) |
Standard: + 24VDC ± 2V (150mA or less) ( * 4), Options: + 15VDC, + 12VDC, ± 15VDC |
35MPa (Problod Department) |
Standard 1kHz (up to 1,300mm stroke) |
± 10ppmfs/℃ or less |
0 ℃ ~+65 ℃ |
-20 ℃ ~+85 ℃ |
GPM setting device |
- | - | - | - | - | - | - | |
GYFC2/3 controller |
Available upon quote |
0.005%FS or less ( * 1), 0.01%FS or less ( * 2) |
0 ~ 10V (load current MAX.5mA, load resistance min.2kΩ), 4 to 20 mA (load resistance max.500Ω) or reversal output, etc. |
- |
Dry B contact 1A 30VDC ( * 3) |
Standard:+24VDC ± 5% (350mA or less), option (*4): ± 15VDC,+12VDC |
- |
Up to standard 1kHz (rod length 1,300mm) ( * 5) |
± 20ppmfs/℃ or less |
0 ℃ ~+65 ℃ |
-20 ℃ ~+85 ℃ |
- |
± 10V (speed resolution 1%FS) |
- | - | - | - | - | - | |
GYDC-S1 digital controller |
Available upon quote |
Standard 0.01mm (minimum 0.001mm) ( * 3), 0.1mm ( * 4) |
- | - |
Open drain ( * 5) |
Standard:+24VDC ± 5% (150mA or less) |
- |
Standard 1kHz (up to 1,300mm long rod) |
± 1 μm/℃ or less ( * 6) |
0 ℃ ~+65 ℃ |
-20 ℃ ~+75 ℃ |
GPM setting device |
- |
Parallel, binaries ( * 1), negative argument ( * 2), 24bit |
- | - | - | - | - | |
GYDC-05 Digital controller |
Available upon quote |
(Digital) Standard 0.01mm (minimum 0.001mm) ( * 3) 0.1mm ( * 4), (analog) 16bit (1/65,536) ( * 3) 0.01%or less ( * 4) |
(Analog) 0 ~ 10V (load current MAX.5MA, load resistance min.2kΩ) or 4 ~ 20mA (load resistance max.500Ω) |
± 10V or 4 ~ 20mA (analog) |
Open collector 0.1a 30VDC ( * 5) |
Standard:+24VDC ± 5% (150mA or less) |
- |
Standard 1kHz (up to 1,300mm long rod) |
± 10ppmfs/℃ or less |
0 ℃ ~+65 ℃ |
-20 ℃ ~+75 ℃ |
GPM setting device |
- |
Parallel, binary ( * 1), negative argument ( * 2) (Options: Added SSI or A/B phase pulse output) (Digital 24bit) |
- | - | - | - | - | |
DC-Q-G controller |
Available upon quote | - | - | - | - | - | - |
Standard 1kHz (up to 1,000mm long rod) |
- |
0 ℃ ~ 60 ℃ |
-20 ℃ ~ 75 ℃ |
- | - |
(Maximum value) G1 type: 1 μm, G2 type: 0.1mm, G3 type: 0.1mm |
1 or 2 axis |
32 points |
1 axis: 0.7a (DC 5V), 2 axis: 0.9A (DC 5V) |
Current value detection (with scaling function), current value setting (with external preset function), upper and lower limit detection, RAS function |
Up to 200m (standard) (G3 type: 100m) Up to 200m (robot) (G3 type: 100m) |
|
IRDS-GY |
Available upon quote |
G1, G4: 1μm, G2, G3, G5, G6: 0.1mm |
- | - | - |
'+24VDC (± 10%) 150ma (supplied from IRD bus) |
- |
Standard 1kHz (up to 1,000mm long rod) |
- |
0 ℃ ~+55 ℃ |
-25 ℃ ~+75 ℃ |
- | - | - |
IRDS-GY10: 1 axis, IRDS-GY20: 2 axis |
- | - | - | - |
Click on the part number for more information about each product