Product
CO2 sensor controller Marvel NMA-VRC-II series (standard size) for "visualization of ventilation" infection measuresHandling Company
Sea Hichi Sea System Co., Ltd.Items marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | Analog output current output | Analog output output width | Analog output voltage output | CO2 Atm dependence | CO2 Temperature dependence | CO2 measurement method | CO2 warm -up | Co2 response time | Correction (calibration) function | Data recording | Digital output | LCD display | LED display | Measurement interval | Measurement range | Product warranty period | Relay output | Relay setting range CO2 | Sensor predictive life | accuracy | alarm | power consumption | power supply | size | terms of use | type | weight |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
NMA-VRC-II |
$ 429.00〜 | 4 ~ 20ma: CO2 | Alarm1 ~ Alarm2 | 0 ~ 10V: CO2 | With 0.13% advanced adjustment function permmHg (0m in factory shipment) | Great numbers of ± 0.2%or ± 2 ppm per 1 ° C (25 ° C standard) | Optical type NDIR (non -scattered infrared absorption method) dual beam sensor | Within 60 seconds | 2 minutes or less (90%) | Manual correction (calibration) | - | - | All display/CO2 concentration only display/hide selection (3 screen switching possible) | 3 color switching lit by CO2 concentration (hidden selection can be selected) | 5 seconds (Updata Period) |
・ CO2: 0 ~ 3,000ppm ・ Temperature: 0 to 50 ℃ ・ Humidity: 20 to 90% |
One year | Max 2a (30VDC or 250vac). 1) If it exceeds the contact and the normal open AL2, it is ON, and if it falls below AL1, it is OFF (reverse setting is also possible). |
・ ALARM1: 100-2,980PPM ・ ALARM2: 120 ~ 3,000ppm |
About 10 years | CO2: Within a large number of ± 75ppm or ± 5%(0ppm ~ 3,000 ppm) |
・ ALARM1 or higher 4 times ・ ALARM2 or higher sounds 8 times ・ MUTE has a function |
Approximately 1.5W | DC24V | W120 x H120 x D28mm |
・ Temperature: 0 to 50 ℃ ・ Humidity: 95%or less dew condensation (an environment with an airflow of 0.1m/s or more is recommended) |
Standard type | 220 | |
NMA-VRC-Iim |
$ 462.00〜 | 4 ~ 20ma: CO2 | Alarm1 ~ Alarm2 | 0 ~ 10V: CO2 | With 0.13% advanced adjustment function permmHg (0m in factory shipment) | Great numbers of ± 0.2%or ± 2 ppm per 1 ° C (25 ° C standard) | Optical type NDIR (non -scattered infrared absorption method) dual beam sensor | Within 60 seconds | 2 minutes or less (90%) | Manual correction (calibration) | - | RS485 MODBUS RTU | All display/CO2 concentration only display/hide selection (3 screen switching possible) | 3 color switching lit by CO2 concentration (hidden selection can be selected) | 5 seconds (Updata Period) |
・ CO2: 0 ~ 3,000ppm ・ Temperature: 0 to 50 ℃ ・ Humidity: 20 to 90% |
One year | Max 2a (30VDC or 250vac). 1) If it exceeds the contact and the normal open AL2, it is ON, and if it falls below AL1, it is OFF (reverse setting is also possible). |
・ ALARM1: 100-2,980PPM ・ ALARM2: 120 ~ 3,000ppm |
About 10 years | CO2: Within a large number of ± 75ppm or ± 5%(0ppm ~ 3,000 ppm) |
・ ALARM1 or higher 4 times ・ ALARM2 or higher sounds 8 times ・ MUTE has a function |
Approximately 1.5W | DC24V | W120 x H120 x D28mm |
・ Temperature: 0 to 50 ℃ ・ Humidity: 95%or less dew condensation (an environment with an airflow of 0.1m/s or more is recommended) |
RS-485MODBUS type | 220 | |
NMA-VRC-Iid |
$ 495.00〜 | 4 ~ 20ma: CO2 | Alarm1 ~ Alarm2 | 0 ~ 10V: CO2 | With 0.13% advanced adjustment function permmHg (0m in factory shipment) | Great numbers of ± 0.2%or ± 2 ppm per 1 ° C (25 ° C standard) | Optical type NDIR (non -scattered infrared absorption method) dual beam sensor | Within 60 seconds | 2 minutes or less (90%) | Manual correction (calibration) | CO2 concentration, temperature, and humidity are recorded on microSD card (attached) every 5 seconds. About 2 years in 1GB | - | All display/CO2 concentration only display/hide selection (3 screen switching possible) | 3 color switching lit by CO2 concentration (hidden selection can be selected) | 5 seconds (Updata Period) |
・ CO2: 0 ~ 3,000ppm ・ Temperature: 0 to 50 ℃ ・ Humidity: 20 to 90% |
One year | Max 2a (30VDC or 250vac). 1) If it exceeds the contact and the normal open AL2, it is ON, and if it falls below AL1, it is OFF (reverse setting is also possible). |
・ ALARM1: 100-2,980PPM ・ ALARM2: 120 ~ 3,000ppm |
About 10 years | CO2: Within a large number of ± 75ppm or ± 5%(0ppm ~ 3,000 ppm) |
・ ALARM1 or higher 4 times ・ ALARM2 or higher sounds 8 times ・ MUTE has a function |
Approximately 1.5W | DC24V | W120 x H120 x D28mm |
・ Temperature: 0 to 50 ℃ ・ Humidity: 95%or less dew condensation (an environment with an airflow of 0.1m/s or more is recommended) |
Built -in data logger. Record CO2 concentration, temperature and humidity. | 220 |
Click on the part number for more information about each product
Sea Hichi Sea System Co., Ltd.