Product
Magnetic distortion linear sensor GY series that measures straight line displacement [Controller]Handling Company
SANTEST CO., LTDItems marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | Alarm output | Bearing pressure | I/O occupied number | Internal power consumption | Number of location detection axes | Operating temperature limit | Optional Accessories | Position output | Position output (OUT1) (OUT2: Option) | Sampling frequency | Save temperature range | Speed output (OUT2) (optional) | Speed output (VEL) (optional) | Supply power supply | Temperature characteristics | cable length | function | resolution |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
GYHC analog controller |
Available upon quote | Open collector 0.1a 30VDC ( * 3) | 35MPa (Problod Department) | - | - | - | 0 ℃ ~+65 ℃ | GPM setting device | - | 0 ~ 10V (load current MAX.5mA, load resistance min.2kΩ) or 4 ~ 20mA (load resistance max.500Ω) | Standard 1kHz (up to 1,300mm stroke) | -20 ℃ ~+85 ℃ | ± 10V or 4 ~ 20ma | - | Standard: + 24VDC ± 2V (150mA or less) ( * 4), Options: + 15VDC, + 12VDC, ± 15VDC | ± 10ppmfs/℃ or less | - | - | 16bit (1/65,336) ( * 1), 0.01%or less ( * 2) | |
GYFC2/3 controller |
Available upon quote | Dry B contact 1A 30VDC ( * 3) | - | - | - | - | 0 ℃ ~+65 ℃ | - | - | 0 ~ 10V (load current MAX.5mA, load resistance min.2kΩ), 4 to 20 mA (load resistance max.500Ω) or reversal output, etc. | Up to standard 1kHz (rod length 1,300mm) ( * 5) | -20 ℃ ~+85 ℃ | - | ± 10V (speed resolution 1%FS) | Standard:+24VDC ± 5% (350mA or less), option (*4): ± 15VDC,+12VDC | ± 20ppmfs/℃ or less | - | - | 0.005%FS or less ( * 1), 0.01%FS or less ( * 2) | |
GYDC-S1 digital controller |
Available upon quote | Open drain ( * 5) | - | - | - | - | 0 ℃ ~+65 ℃ | GPM setting device | Parallel, binaries ( * 1), negative argument ( * 2), 24bit | - | Standard 1kHz (up to 1,300mm long rod) | -20 ℃ ~+75 ℃ | - | - | Standard:+24VDC ± 5% (150mA or less) | ± 1 μm/℃ or less ( * 6) | - | - | Standard 0.01mm (minimum 0.001mm) ( * 3), 0.1mm ( * 4) | |
GYDC-05 Digital controller |
Available upon quote | Open collector 0.1a 30VDC ( * 5) | - | - | - | - | 0 ℃ ~+65 ℃ | GPM setting device | Parallel, binary ( * 1), negative argument ( * 2) (Options: Added SSI or A/B phase pulse output) (Digital 24bit) | (Analog) 0 ~ 10V (load current MAX.5MA, load resistance min.2kΩ) or 4 ~ 20mA (load resistance max.500Ω) | Standard 1kHz (up to 1,300mm long rod) | -20 ℃ ~+75 ℃ | ± 10V or 4 ~ 20mA (analog) | - | Standard:+24VDC ± 5% (150mA or less) | ± 10ppmfs/℃ or less | - | - | (Digital) Standard 0.01mm (minimum 0.001mm) ( * 3) 0.1mm ( * 4), (analog) 16bit (1/65,536) ( * 3) 0.01%or less ( * 4) | |
DC-Q-G controller |
Available upon quote | - | - | 32 points | 1 axis: 0.7a (DC 5V), 2 axis: 0.9A (DC 5V) | 1 or 2 axis | 0 ℃ ~ 60 ℃ | - | (Maximum value) G1 type: 1 μm, G2 type: 0.1mm, G3 type: 0.1mm | - | Standard 1kHz (up to 1,000mm long rod) | -20 ℃ ~ 75 ℃ | - | - | - | - | Up to 200m (standard) (G3 type: 100m) Up to 200m (robot) (G3 type: 100m) | Current value detection (with scaling function), current value setting (with external preset function), upper and lower limit detection, RAS function | - | |
IRDS-GY |
Available upon quote | - | - | - | - | IRDS-GY10: 1 axis, IRDS-GY20: 2 axis | 0 ℃ ~+55 ℃ | - | - | - | Standard 1kHz (up to 1,000mm long rod) | -25 ℃ ~+75 ℃ | - | - | '+24VDC (± 10%) 150ma (supplied from IRD bus) | - | - | - | G1, G4: 1μm, G2, G3, G5, G6: 0.1mm |
Click on the part number for more information about each product