Product
Magnetic distortion linear sensor GY series that measures straight line displacement [Rod shape] <All -in -one series> Integrated controllerHandling Company
SANTEST CO., LTDItems marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | Alarm output | Bearing pressure | Current output | Impact resistance | Linearness | Location detection (standard) | Operating temperature limit | Optional Accessories | Output format | Position output | Protection standard | Repetition | Sampling frequency | Save temperature range | Speed output | Supply power supply | Temperature characteristics | Vibration resistance | Voltage output | output | resolution |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Gymra probe |
Available upon quote | Open drain 50V 0.1a (when dropping magnet) | 35MPa (Problod Department) | 4 ~ 20ma or 20 ~ 4 ma (load resistance MAX.500Ω) | 100g (2msec) | ± 0.025%FS or less Typ. | - | -20 ℃ ~+75 ℃ | GPM setting device | - | - | IP67 | ± 0.1mm or less | Standard 1kHz (up to 1,300mm long rod) | -40 ℃ ~+75 ℃ | - | +24 (±2) VDC (60mA) | ± 20ppmfs/℃ or less | 15g (20-100Hz) | 0 ~ 10V or 10 ~ 0V (load current MAX.5MA, load resistance min.2kΩ) | - | 0.1mm or less | |
GYMRS probe |
Available upon quote | Open drain 50V 0.1a (when dropping magnet) | - | - | 100g (2msec) | ± 0.025%FS or less Typ. | SSI (asynchronous), 24 ~ 27bit, binary (standard) or gray | -20 ℃ ~+75 ℃ | - | - | - | IP67 | 0.001% FS or less (minimum ± 3 μm or less) | Standard 1kHz (total length 1,300mm) * 1 | -40 ℃ ~+75 ℃ | Not applicable | DC24V (± 2V) 80ma | 20ppmfs/℃ | 15g (10-100Hz) | - | - | 0.1mm ~ 0.1μm | |
GYMF-S probe |
Available upon quote | Open drain 50V 0.1a (when dropping magnet) | 35MPa (Problod Department) | - | - | ± 0.025%FS or less Typ. | SSI (asynchronous), 24 ~ 27bit, binary (standard) or gray | -20 ℃ ~+75 ℃ | - | - | - | IP67 | 0.001% FS or less (minimum ± 3 μm or less) | Standard 1kHz (total length 1,300mm) * 1 | -40 ℃ ~+75 ℃ | - | DC24V (± 2V) 80ma | 20ppmfs/℃ | 100g (2msec) | - | - | 0.1mm ~ 0.1μm | |
Gyma probe |
Available upon quote | none | 35MPa (Problod Department) | 4 ~ 20ma or 20 ~ 4 ma (load resistance MAX.500Ω) | 50g (2msec) | ± 0.025%FS or less Typ. | - | -20 ℃ ~+80 ℃ | GPM setting device | - | - | IP67 | ± 0.1mm or less | Standard 1kHz (up to 1,300mm long rod) | -40 ℃ ~+80 ℃ | - | +24 (± 2) VDC (100ma) | ± 0.03%FS/℃ or less | 6g (or 40Hz 2MPP) | 0 ~ 10V or 10 ~ 0V (load current MAX.5MA, load resistance min. 2kΩ) | - | 0.1mm or less | |
Gyms probe |
Available upon quote | - | 35MPa (Problod Department) | - | 50g (2msec) | ± 0.025%FS or less Typ. | - | -20 ℃ ~+80 ℃ | - | - | - | IP67 | ± 0.01 % FS or less | - | -40 ℃ ~+80 ℃ | - | - | ± 40ppmfs/℃ or less | 6g (or 40Hz 2MPP) | - | - | (Analog) 0.01%FS or less, (digital) 0.1mm | |
GysE-A probe |
Available upon quote | Open drain 50V 0.1a (when dropping magnet) | 35MPa (Problod Department) | - | 100g (2msec) | ± 0.025%FS or less Typ. | - | -20 ℃ ~+75 ℃ | GPM setting device | - | - | IP67 | ± 0.001%FS or less (min. ± 3 μm) | Standard 1kHz (up to 1,300mm long rod) | -40 ℃ ~+75 ℃ | ± 10V (load current MAX.5ma, load resistance min.2kΩ), or 4 to 20 mA (load resistance MAX.500Ω) (optional) | +24 (± 2) VDC (80ma) | ± 20ppmfs/℃ or less | 15g (10-100Hz) | - | - | 16bit (1/65,536) | |
GysE-Q probe |
Available upon quote | Open drain 50V 0.1a (when dropping magnet) | 35MPa (Problod Department) | - | 100g (2msec) | ± 0.025%FS or less Typ. | - | -20 ℃ ~+75 ℃ | GPM setting device | Incremental output | A/B pulse pulse (4 times) (Z phase) RS422 differential driver | IP67 | ± 0.001%FS or less (min. ± 3 μm) | Standard 1kHz (up to 1,300mm long rod) | -40 ℃ ~+75 ℃ | - | +24 (± 2) VDC (150ma) | ± 15ppmfs/℃ or less | 15g (20-100Hz) | - | - | Select between 0.1mm and 0.001mm | |
GySE-S probe |
Available upon quote | Open drain 50V 0.1a (when dropping magnet) | 35MPa (Problod Department) | - | 100g (2msec) | ± 0.025%FS or less Typ. | - | -20 ℃ ~+75 ℃ | SSPC-03 (SSI → parallel output converter) | SSI output | SSI, 24-27bit, binary (standard) or gray | IP67 | ± 0.001%FS or less (min. ± 3 μm) | Standard 1kHz (up to 1,300mm long rod) | -40 ℃ ~+75 ℃ | - | +24 (± 2) VDC (70ma) | ± 15ppmfs/℃ or less | 15g (20-100Hz) | - | - | Select between 0.1mm and 0.001mm | |
GysE-P probe |
Available upon quote | - | 35MPa (Problod Department) | - | 100g (2msec) | ± 0.025%FS or less Typ. | - | -20 ℃ ~+75 ℃ | Profibus Master Simulator | - | - | IP67 | ± 0.001%FS or less | Stroke ~ 800mm: 2,000Hz, ~ 2,200mm: 1,000Hz, ~ 5,000mm: 500Hz, 5,001mm ~: 250Hz * 1 | -40 ℃ ~+75 ℃ | - | +24 (± 2) VDC (70ma) | ± 15ppmfs/℃ or less | 15g (20-100Hz) | - | PROFIBUS DPV0 | Min.1μm (configuration in Profibus DP Configurator) | |
Gyse-ep2 probe |
Available upon quote | - | - | - | 100g (2msec) | ± 0.025%FS or less Typ. | - | -20 ℃ ~+75 ℃ | - | - | - | IP67 | ± 0.001%FS or less (min. ± 3 μm) | 1kHz (1,300mm or less), 500Hz (2,400mm or less), 250Hz (2,401mm or more) | -40 ℃ ~+75 ℃ | - | +24VDC (± 5%) (110mA) | ± 15ppmfs/℃ or less | 15g (20-100Hz) | - | Ethernet/IP | Location: minimum 1 μm (minimum multi -magnet time 10 μm), speed: minimum 1 μm/sec, set at Configuration Assembly at the start of communication. |
Click on the part number for more information about each product