Price (excluding tax)
Estimate Required
Model Description
■ Same shape as GYMA, current output only
・ Standard type of compact series. It is a design with a compact sensor head.
・ Linearly ± 0.025%improvements are improved by achieving FS. In addition, the probe protection standard IP67 design has improved reliability.
■ Combination controller
・ GYHC: High -precision/high -performance analog output, 16 -bit decomposition ability, 2ch output, speed output, 2 points, 2 points output, high -speed sampling
・ GYDC-S1: Digital output (parallel output), standard type
・ GYDC-05: High accuracy/high-performance digital output, parallel output, A/B phase pulse output, SSI output addition, high-speed sampling
・ IRDS-GY: Connect with CC-LINK, CC-Link IE Field, ProFibus, Ethernet/IP, Ethernet, connected to IRDS-GY.
■ performance
・ Rod resistant 35MPa: Linear sensor that can be built into the hydraulic cylinder
・ Controller body compact: Controller body type
* Accuracy is applied to a sensor with an effective stroke of 300mm or more. A sensor of less than 300mm is equivalent to a 300mm sensor specification.
Model Filter
You can search for other models from each index. The displayed value is the value of the currently selected part number.
Alarm output
Open drain 50V 0.1a (when dropping magnet) | Gymra probe
Open drain 50V 0.1a (when dropping magnet) | GYMRS probe
Open drain 50V 0.1a (when dropping magnet) | GYMF-S probe
none | Gyma probe
Open drain 50V 0.1a (when dropping magnet) | GysE-A probe
Open drain 50V 0.1a (when dropping magnet) | GysE-Q probe
Open drain 50V 0.1a (when dropping magnet) | GySE-S probe
Bearing pressure
35MPa (Problod Department) | Gymra probe
35MPa (Problod Department) | GYMF-S probe
35MPa (Problod Department) | Gyma probe
35MPa (Problod Department)
35MPa (Problod Department) | GysE-A probe
35MPa (Problod Department) | GysE-Q probe
35MPa (Problod Department) | GySE-S probe
35MPa (Problod Department) | GysE-P probe
Current output
4 ~ 20ma or 20 ~ 4 ma (load resistance MAX.500Ω) | Gymra probe
4 ~ 20ma or 20 ~ 4 ma (load resistance MAX.500Ω) | Gyma probe
Impact resistance
100g (2msec) | Gymra probe
100g (2msec) | GYMRS probe
50g (2msec) | Gyma probe
50g (2msec)
100g (2msec) | GysE-A probe
100g (2msec) | GysE-Q probe
100g (2msec) | GySE-S probe
100g (2msec) | GysE-P probe
100g (2msec) | Gyse-ep2 probe
Linearness
± 0.025%FS or less Typ. | Gymra probe
± 0.025%FS or less Typ. | GYMRS probe
± 0.025%FS or less Typ. | GYMF-S probe
± 0.025%FS or less Typ. | Gyma probe
± 0.025%FS or less Typ.
± 0.025%FS or less Typ. | GysE-A probe
± 0.025%FS or less Typ. | GysE-Q probe
± 0.025%FS or less Typ. | GySE-S probe
± 0.025%FS or less Typ. | GysE-P probe
± 0.025%FS or less Typ. | Gyse-ep2 probe
Operating temperature limit
-20 ℃ ~+75 ℃ | Gymra probe
-20 ℃ ~+75 ℃ | GYMRS probe
-20 ℃ ~+75 ℃ | GYMF-S probe
-20 ℃ ~+80 ℃ | Gyma probe
-20 ℃ ~+80 ℃
-20 ℃ ~+75 ℃ | GysE-A probe
-20 ℃ ~+75 ℃ | GysE-Q probe
-20 ℃ ~+75 ℃ | GySE-S probe
-20 ℃ ~+75 ℃ | GysE-P probe
-20 ℃ ~+75 ℃ | Gyse-ep2 probe
Optional Accessories
GPM setting device | Gymra probe
GPM setting device | Gyma probe
GPM setting device | GysE-A probe
GPM setting device | GysE-Q probe
SSPC-03 (SSI → parallel output converter) | GySE-S probe
Profibus Master Simulator | GysE-P probe
Protection standard
IP67 | Gymra probe
IP67 | GYMRS probe
IP67 | GYMF-S probe
IP67 | Gyma probe
IP67
IP67 | GysE-A probe
IP67 | GysE-Q probe
IP67 | GySE-S probe
IP67 | GysE-P probe
IP67 | Gyse-ep2 probe
Repetition
± 0.1mm or less | Gymra probe
0.001% FS or less (minimum ± 3 μm or less) | GYMRS probe
0.001% FS or less (minimum ± 3 μm or less) | GYMF-S probe
± 0.1mm or less | Gyma probe
± 0.01 % FS or less
± 0.001%FS or less (min. ± 3 μm) | GysE-A probe
± 0.001%FS or less (min. ± 3 μm) | GysE-Q probe
± 0.001%FS or less (min. ± 3 μm) | GySE-S probe
± 0.001%FS or less | GysE-P probe
± 0.001%FS or less (min. ± 3 μm) | Gyse-ep2 probe
Sampling frequency
Standard 1kHz (up to 1,300mm long rod) | Gymra probe
Standard 1kHz (total length 1,300mm) * 1 | GYMRS probe
Standard 1kHz (total length 1,300mm) * 1 | GYMF-S probe
Standard 1kHz (up to 1,300mm long rod) | Gyma probe
Standard 1kHz (up to 1,300mm long rod) | GysE-A probe
Standard 1kHz (up to 1,300mm long rod) | GysE-Q probe
Standard 1kHz (up to 1,300mm long rod) | GySE-S probe
Stroke ~ 800mm: 2,000Hz, ~ 2,200mm: 1,000Hz, ~ 5,000mm: 500Hz, 5,001mm ~: 250Hz * 1 | GysE-P probe
1kHz (1,300mm or less), 500Hz (2,400mm or less), 250Hz (2,401mm or more) | Gyse-ep2 probe
Save temperature range
-40 ℃ ~+75 ℃ | Gymra probe
-40 ℃ ~+75 ℃ | GYMRS probe
-40 ℃ ~+75 ℃ | GYMF-S probe
-40 ℃ ~+80 ℃ | Gyma probe
-40 ℃ ~+80 ℃
-40 ℃ ~+75 ℃ | GysE-A probe
-40 ℃ ~+75 ℃ | GysE-Q probe
-40 ℃ ~+75 ℃ | GySE-S probe
-40 ℃ ~+75 ℃ | GysE-P probe
-40 ℃ ~+75 ℃ | Gyse-ep2 probe
Supply power supply
+24 (±2) VDC (60mA) | Gymra probe
DC24V (± 2V) 80ma | GYMRS probe
DC24V (± 2V) 80ma | GYMF-S probe
+24 (± 2) VDC (100ma) | Gyma probe
+24 (± 2) VDC (80ma) | GysE-A probe
+24 (± 2) VDC (150ma) | GysE-Q probe
+24 (± 2) VDC (70ma) | GySE-S probe
+24 (± 2) VDC (70ma) | GysE-P probe
+24VDC (± 5%) (110mA) | Gyse-ep2 probe
Temperature characteristics
± 20ppmfs/℃ or less | Gymra probe
20ppmfs/℃ | GYMRS probe
20ppmfs/℃ | GYMF-S probe
± 0.03%FS/℃ or less | Gyma probe
± 40ppmfs/℃ or less
± 20ppmfs/℃ or less | GysE-A probe
± 15ppmfs/℃ or less | GysE-Q probe
± 15ppmfs/℃ or less | GySE-S probe
± 15ppmfs/℃ or less | GysE-P probe
± 15ppmfs/℃ or less | Gyse-ep2 probe
Vibration resistance
15g (20-100Hz) | Gymra probe
15g (10-100Hz) | GYMRS probe
100g (2msec) | GYMF-S probe
6g (or 40Hz 2MPP) | Gyma probe
6g (or 40Hz 2MPP)
15g (10-100Hz) | GysE-A probe
15g (20-100Hz) | GysE-Q probe
15g (20-100Hz) | GySE-S probe
15g (20-100Hz) | GysE-P probe
15g (20-100Hz) | Gyse-ep2 probe
Voltage output
0 ~ 10V or 10 ~ 0V (load current MAX.5MA, load resistance min.2kΩ) | Gymra probe
0 ~ 10V or 10 ~ 0V (load current MAX.5MA, load resistance min. 2kΩ) | Gyma probe
resolution
0.1mm or less | Gymra probe
0.1mm ~ 0.1μm | GYMRS probe
0.1mm ~ 0.1μm | GYMF-S probe
0.1mm or less | Gyma probe
(Analog) 0.01%FS or less, (digital) 0.1mm
16bit (1/65,536) | GysE-A probe
Select between 0.1mm and 0.001mm | GysE-Q probe
Select between 0.1mm and 0.001mm | GySE-S probe
Min.1μm (configuration in Profibus DP Configurator) | GysE-P probe
Location: minimum 1 μm (minimum multi -magnet time 10 μm), speed: minimum 1 μm/sec, set at Configuration Assembly at the start of communication. | Gyse-ep2 probe
Location detection (standard)
SSI (asynchronous), 24 ~ 27bit, binary (standard) or gray | GYMRS probe
SSI (asynchronous), 24 ~ 27bit, binary (standard) or gray | GYMF-S probe
Speed output
Not applicable | GYMRS probe
± 10V (load current MAX.5ma, load resistance min.2kΩ), or 4 to 20 mA (load resistance MAX.500Ω) (optional) | GysE-A probe
Output format
Incremental output | GysE-Q probe
SSI output | GySE-S probe
Position output
A/B pulse pulse (4 times) (Z phase) RS422 differential driver | GysE-Q probe
SSI, 24-27bit, binary (standard) or gray | GySE-S probe
output
PROFIBUS DPV0 | GysE-P probe
Ethernet/IP | Gyse-ep2 probe
See all 10 models in list