Price (excluding tax)
Estimate Required
Model Description
■ Ethernet/IP output type, decomposition ability: 1 μm, up to 20 magnets can be detected
・ Ethernet/IP Output type GY sensor.
-A adapter device that outputs Ethernet/IP for magnet displacement and speed. You can also measure the position and speed of up to 20 detected magnets with one sensor at the same time.
・ You can remove and replace the sensor gag from the housing.
■ Features
・ Ethernet/IP ™ Output: This product is an adapter device that outputs magnet displacement and speed in Ethernet/IP ™ Class 1 Connection.
・ Multi -magnet position speed output: One sensor can measure up to 20 detected magnets and speeds at the same time.
■ performance
・ High resolution: Location: minimum 1km, EM: 1 m secret
・ Industrial network: Ethernet/IP output
・ Multi -point watch measurement: Up to 20 magnets can be measured the same clock
Model Filter
You can search for other models from each index. The displayed value is the value of the currently selected part number.
Alarm output
Open drain 50V 0.1a (when dropping magnet) | Gymra probe
Open drain 50V 0.1a (when dropping magnet) | GYMRS probe
Open drain 50V 0.1a (when dropping magnet) | GYMF-S probe
none | Gyma probe
Open drain 50V 0.1a (when dropping magnet) | GysE-A probe
Open drain 50V 0.1a (when dropping magnet) | GysE-Q probe
Open drain 50V 0.1a (when dropping magnet) | GySE-S probe
Bearing pressure
35MPa (Problod Department) | Gymra probe
35MPa (Problod Department) | GYMF-S probe
35MPa (Problod Department) | Gyma probe
35MPa (Problod Department) | Gyms probe
35MPa (Problod Department) | GysE-A probe
35MPa (Problod Department) | GysE-Q probe
35MPa (Problod Department) | GySE-S probe
35MPa (Problod Department) | GysE-P probe
Current output
4 ~ 20ma or 20 ~ 4 ma (load resistance MAX.500Ω) | Gymra probe
4 ~ 20ma or 20 ~ 4 ma (load resistance MAX.500Ω) | Gyma probe
Impact resistance
100g (2msec) | Gymra probe
100g (2msec) | GYMRS probe
50g (2msec) | Gyma probe
50g (2msec) | Gyms probe
100g (2msec) | GysE-A probe
100g (2msec) | GysE-Q probe
100g (2msec) | GySE-S probe
100g (2msec) | GysE-P probe
100g (2msec)
Linearness
± 0.025%FS or less Typ. | Gymra probe
± 0.025%FS or less Typ. | GYMRS probe
± 0.025%FS or less Typ. | GYMF-S probe
± 0.025%FS or less Typ. | Gyma probe
± 0.025%FS or less Typ. | Gyms probe
± 0.025%FS or less Typ. | GysE-A probe
± 0.025%FS or less Typ. | GysE-Q probe
± 0.025%FS or less Typ. | GySE-S probe
± 0.025%FS or less Typ. | GysE-P probe
± 0.025%FS or less Typ.
Operating temperature limit
-20 ℃ ~+75 ℃ | Gymra probe
-20 ℃ ~+75 ℃ | GYMRS probe
-20 ℃ ~+75 ℃ | GYMF-S probe
-20 ℃ ~+80 ℃ | Gyma probe
-20 ℃ ~+80 ℃ | Gyms probe
-20 ℃ ~+75 ℃ | GysE-A probe
-20 ℃ ~+75 ℃ | GysE-Q probe
-20 ℃ ~+75 ℃ | GySE-S probe
-20 ℃ ~+75 ℃ | GysE-P probe
-20 ℃ ~+75 ℃
Optional Accessories
GPM setting device | Gymra probe
GPM setting device | Gyma probe
GPM setting device | GysE-A probe
GPM setting device | GysE-Q probe
SSPC-03 (SSI → parallel output converter) | GySE-S probe
Profibus Master Simulator | GysE-P probe
Protection standard
IP67 | Gymra probe
IP67 | GYMRS probe
IP67 | GYMF-S probe
IP67 | Gyma probe
IP67 | Gyms probe
IP67 | GysE-A probe
IP67 | GysE-Q probe
IP67 | GySE-S probe
IP67 | GysE-P probe
IP67
Repetition
± 0.1mm or less | Gymra probe
0.001% FS or less (minimum ± 3 μm or less) | GYMRS probe
0.001% FS or less (minimum ± 3 μm or less) | GYMF-S probe
± 0.1mm or less | Gyma probe
± 0.01 % FS or less | Gyms probe
± 0.001%FS or less (min. ± 3 μm) | GysE-A probe
± 0.001%FS or less (min. ± 3 μm) | GysE-Q probe
± 0.001%FS or less (min. ± 3 μm) | GySE-S probe
± 0.001%FS or less | GysE-P probe
± 0.001%FS or less (min. ± 3 μm)
Sampling frequency
Standard 1kHz (up to 1,300mm long rod) | Gymra probe
Standard 1kHz (total length 1,300mm) * 1 | GYMRS probe
Standard 1kHz (total length 1,300mm) * 1 | GYMF-S probe
Standard 1kHz (up to 1,300mm long rod) | Gyma probe
Standard 1kHz (up to 1,300mm long rod) | GysE-A probe
Standard 1kHz (up to 1,300mm long rod) | GysE-Q probe
Standard 1kHz (up to 1,300mm long rod) | GySE-S probe
Stroke ~ 800mm: 2,000Hz, ~ 2,200mm: 1,000Hz, ~ 5,000mm: 500Hz, 5,001mm ~: 250Hz * 1 | GysE-P probe
1kHz (1,300mm or less), 500Hz (2,400mm or less), 250Hz (2,401mm or more)
Save temperature range
-40 ℃ ~+75 ℃ | Gymra probe
-40 ℃ ~+75 ℃ | GYMRS probe
-40 ℃ ~+75 ℃ | GYMF-S probe
-40 ℃ ~+80 ℃ | Gyma probe
-40 ℃ ~+80 ℃ | Gyms probe
-40 ℃ ~+75 ℃ | GysE-A probe
-40 ℃ ~+75 ℃ | GysE-Q probe
-40 ℃ ~+75 ℃ | GySE-S probe
-40 ℃ ~+75 ℃ | GysE-P probe
-40 ℃ ~+75 ℃
Supply power supply
+24 (±2) VDC (60mA) | Gymra probe
DC24V (± 2V) 80ma | GYMRS probe
DC24V (± 2V) 80ma | GYMF-S probe
+24 (± 2) VDC (100ma) | Gyma probe
+24 (± 2) VDC (80ma) | GysE-A probe
+24 (± 2) VDC (150ma) | GysE-Q probe
+24 (± 2) VDC (70ma) | GySE-S probe
+24 (± 2) VDC (70ma) | GysE-P probe
+24VDC (± 5%) (110mA)
Temperature characteristics
± 20ppmfs/℃ or less | Gymra probe
20ppmfs/℃ | GYMRS probe
20ppmfs/℃ | GYMF-S probe
± 0.03%FS/℃ or less | Gyma probe
± 40ppmfs/℃ or less | Gyms probe
± 20ppmfs/℃ or less | GysE-A probe
± 15ppmfs/℃ or less | GysE-Q probe
± 15ppmfs/℃ or less | GySE-S probe
± 15ppmfs/℃ or less | GysE-P probe
± 15ppmfs/℃ or less
Vibration resistance
15g (20-100Hz) | Gymra probe
15g (10-100Hz) | GYMRS probe
100g (2msec) | GYMF-S probe
6g (or 40Hz 2MPP) | Gyma probe
6g (or 40Hz 2MPP) | Gyms probe
15g (10-100Hz) | GysE-A probe
15g (20-100Hz) | GysE-Q probe
15g (20-100Hz) | GySE-S probe
15g (20-100Hz) | GysE-P probe
15g (20-100Hz)
Voltage output
0 ~ 10V or 10 ~ 0V (load current MAX.5MA, load resistance min.2kΩ) | Gymra probe
0 ~ 10V or 10 ~ 0V (load current MAX.5MA, load resistance min. 2kΩ) | Gyma probe
resolution
0.1mm or less | Gymra probe
0.1mm ~ 0.1μm | GYMRS probe
0.1mm ~ 0.1μm | GYMF-S probe
0.1mm or less | Gyma probe
(Analog) 0.01%FS or less, (digital) 0.1mm | Gyms probe
16bit (1/65,536) | GysE-A probe
Select between 0.1mm and 0.001mm | GysE-Q probe
Select between 0.1mm and 0.001mm | GySE-S probe
Min.1μm (configuration in Profibus DP Configurator) | GysE-P probe
Location: minimum 1 μm (minimum multi -magnet time 10 μm), speed: minimum 1 μm/sec, set at Configuration Assembly at the start of communication.
Location detection (standard)
SSI (asynchronous), 24 ~ 27bit, binary (standard) or gray | GYMRS probe
SSI (asynchronous), 24 ~ 27bit, binary (standard) or gray | GYMF-S probe
Speed output
Not applicable | GYMRS probe
± 10V (load current MAX.5ma, load resistance min.2kΩ), or 4 to 20 mA (load resistance MAX.500Ω) (optional) | GysE-A probe
Output format
Incremental output | GysE-Q probe
SSI output | GySE-S probe
Position output
A/B pulse pulse (4 times) (Z phase) RS422 differential driver | GysE-Q probe
SSI, 24-27bit, binary (standard) or gray | GySE-S probe
output
PROFIBUS DPV0 | GysE-P probe
Ethernet/IP
See all 10 models in list
Part Number
Gyse-ep2 probe