Price (excluding tax)
Estimate Required
Model Description
■ It is an SSI output type sensor.
・ In the SSI output format, the position data of 24 to 27bit is output with minimal resolution 1 μm.
・ If you use an separately sold SSPC-03 (SSI → parallel converter), you can convert it to parallel data, so you can import it with an I/O unit.
-The sensor ghosts can be removed from the housing and replaced, and by separately sold equipment (with software) (model: GPM), the resolution, code (binary or gray), change of output direction, zero/full scale adjustment are adjusted. Is possible.
* Accuracy is applied to a sensor with an effective stroke of 300mm or more. A sensor of less than 300mm is equivalent to a 300mm sensor specification.
* 1 Sampling frequency can be speeded up to 3.75kHz as options.
Model Filter
You can search for other models from each index. The displayed value is the value of the currently selected part number.
Alarm output
Open drain 50V 0.1a (when dropping magnet) | Gymra probe
Open drain 50V 0.1a (when dropping magnet)
Open drain 50V 0.1a (when dropping magnet) | GYMF-S probe
none | Gyma probe
Open drain 50V 0.1a (when dropping magnet) | GysE-A probe
Open drain 50V 0.1a (when dropping magnet) | GysE-Q probe
Open drain 50V 0.1a (when dropping magnet) | GySE-S probe
Bearing pressure
35MPa (Problod Department) | Gymra probe
35MPa (Problod Department) | GYMF-S probe
35MPa (Problod Department) | Gyma probe
35MPa (Problod Department) | Gyms probe
35MPa (Problod Department) | GysE-A probe
35MPa (Problod Department) | GysE-Q probe
35MPa (Problod Department) | GySE-S probe
35MPa (Problod Department) | GysE-P probe
Current output
4 ~ 20ma or 20 ~ 4 ma (load resistance MAX.500Ω) | Gymra probe
4 ~ 20ma or 20 ~ 4 ma (load resistance MAX.500Ω) | Gyma probe
Impact resistance
100g (2msec) | Gymra probe
100g (2msec)
50g (2msec) | Gyma probe
50g (2msec) | Gyms probe
100g (2msec) | GysE-A probe
100g (2msec) | GysE-Q probe
100g (2msec) | GySE-S probe
100g (2msec) | GysE-P probe
100g (2msec) | Gyse-ep2 probe
Linearness
± 0.025%FS or less Typ. | Gymra probe
± 0.025%FS or less Typ.
± 0.025%FS or less Typ. | GYMF-S probe
± 0.025%FS or less Typ. | Gyma probe
± 0.025%FS or less Typ. | Gyms probe
± 0.025%FS or less Typ. | GysE-A probe
± 0.025%FS or less Typ. | GysE-Q probe
± 0.025%FS or less Typ. | GySE-S probe
± 0.025%FS or less Typ. | GysE-P probe
± 0.025%FS or less Typ. | Gyse-ep2 probe
Operating temperature limit
-20 ℃ ~+75 ℃ | Gymra probe
-20 ℃ ~+75 ℃
-20 ℃ ~+75 ℃ | GYMF-S probe
-20 ℃ ~+80 ℃ | Gyma probe
-20 ℃ ~+80 ℃ | Gyms probe
-20 ℃ ~+75 ℃ | GysE-A probe
-20 ℃ ~+75 ℃ | GysE-Q probe
-20 ℃ ~+75 ℃ | GySE-S probe
-20 ℃ ~+75 ℃ | GysE-P probe
-20 ℃ ~+75 ℃ | Gyse-ep2 probe
Optional Accessories
GPM setting device | Gymra probe
GPM setting device | Gyma probe
GPM setting device | GysE-A probe
GPM setting device | GysE-Q probe
SSPC-03 (SSI → parallel output converter) | GySE-S probe
Profibus Master Simulator | GysE-P probe
Protection standard
IP67 | Gymra probe
IP67
IP67 | GYMF-S probe
IP67 | Gyma probe
IP67 | Gyms probe
IP67 | GysE-A probe
IP67 | GysE-Q probe
IP67 | GySE-S probe
IP67 | GysE-P probe
IP67 | Gyse-ep2 probe
Repetition
± 0.1mm or less | Gymra probe
0.001% FS or less (minimum ± 3 μm or less)
0.001% FS or less (minimum ± 3 μm or less) | GYMF-S probe
± 0.1mm or less | Gyma probe
± 0.01 % FS or less | Gyms probe
± 0.001%FS or less (min. ± 3 μm) | GysE-A probe
± 0.001%FS or less (min. ± 3 μm) | GysE-Q probe
± 0.001%FS or less (min. ± 3 μm) | GySE-S probe
± 0.001%FS or less | GysE-P probe
± 0.001%FS or less (min. ± 3 μm) | Gyse-ep2 probe
Sampling frequency
Standard 1kHz (up to 1,300mm long rod) | Gymra probe
Standard 1kHz (total length 1,300mm) * 1
Standard 1kHz (total length 1,300mm) * 1 | GYMF-S probe
Standard 1kHz (up to 1,300mm long rod) | Gyma probe
Standard 1kHz (up to 1,300mm long rod) | GysE-A probe
Standard 1kHz (up to 1,300mm long rod) | GysE-Q probe
Standard 1kHz (up to 1,300mm long rod) | GySE-S probe
Stroke ~ 800mm: 2,000Hz, ~ 2,200mm: 1,000Hz, ~ 5,000mm: 500Hz, 5,001mm ~: 250Hz * 1 | GysE-P probe
1kHz (1,300mm or less), 500Hz (2,400mm or less), 250Hz (2,401mm or more) | Gyse-ep2 probe
Save temperature range
-40 ℃ ~+75 ℃ | Gymra probe
-40 ℃ ~+75 ℃
-40 ℃ ~+75 ℃ | GYMF-S probe
-40 ℃ ~+80 ℃ | Gyma probe
-40 ℃ ~+80 ℃ | Gyms probe
-40 ℃ ~+75 ℃ | GysE-A probe
-40 ℃ ~+75 ℃ | GysE-Q probe
-40 ℃ ~+75 ℃ | GySE-S probe
-40 ℃ ~+75 ℃ | GysE-P probe
-40 ℃ ~+75 ℃ | Gyse-ep2 probe
Supply power supply
+24 (±2) VDC (60mA) | Gymra probe
DC24V (± 2V) 80ma
DC24V (± 2V) 80ma | GYMF-S probe
+24 (± 2) VDC (100ma) | Gyma probe
+24 (± 2) VDC (80ma) | GysE-A probe
+24 (± 2) VDC (150ma) | GysE-Q probe
+24 (± 2) VDC (70ma) | GySE-S probe
+24 (± 2) VDC (70ma) | GysE-P probe
+24VDC (± 5%) (110mA) | Gyse-ep2 probe
Temperature characteristics
± 20ppmfs/℃ or less | Gymra probe
20ppmfs/℃
20ppmfs/℃ | GYMF-S probe
± 0.03%FS/℃ or less | Gyma probe
± 40ppmfs/℃ or less | Gyms probe
± 20ppmfs/℃ or less | GysE-A probe
± 15ppmfs/℃ or less | GysE-Q probe
± 15ppmfs/℃ or less | GySE-S probe
± 15ppmfs/℃ or less | GysE-P probe
± 15ppmfs/℃ or less | Gyse-ep2 probe
Vibration resistance
15g (20-100Hz) | Gymra probe
15g (10-100Hz)
100g (2msec) | GYMF-S probe
6g (or 40Hz 2MPP) | Gyma probe
6g (or 40Hz 2MPP) | Gyms probe
15g (10-100Hz) | GysE-A probe
15g (20-100Hz) | GysE-Q probe
15g (20-100Hz) | GySE-S probe
15g (20-100Hz) | GysE-P probe
15g (20-100Hz) | Gyse-ep2 probe
Voltage output
0 ~ 10V or 10 ~ 0V (load current MAX.5MA, load resistance min.2kΩ) | Gymra probe
0 ~ 10V or 10 ~ 0V (load current MAX.5MA, load resistance min. 2kΩ) | Gyma probe
resolution
0.1mm or less | Gymra probe
0.1mm ~ 0.1μm
0.1mm ~ 0.1μm | GYMF-S probe
0.1mm or less | Gyma probe
(Analog) 0.01%FS or less, (digital) 0.1mm | Gyms probe
16bit (1/65,536) | GysE-A probe
Select between 0.1mm and 0.001mm | GysE-Q probe
Select between 0.1mm and 0.001mm | GySE-S probe
Min.1μm (configuration in Profibus DP Configurator) | GysE-P probe
Location: minimum 1 μm (minimum multi -magnet time 10 μm), speed: minimum 1 μm/sec, set at Configuration Assembly at the start of communication. | Gyse-ep2 probe
Location detection (standard)
SSI (asynchronous), 24 ~ 27bit, binary (standard) or gray
SSI (asynchronous), 24 ~ 27bit, binary (standard) or gray | GYMF-S probe
Speed output
Not applicable
± 10V (load current MAX.5ma, load resistance min.2kΩ), or 4 to 20 mA (load resistance MAX.500Ω) (optional) | GysE-A probe
Output format
Incremental output | GysE-Q probe
SSI output | GySE-S probe
Position output
A/B pulse pulse (4 times) (Z phase) RS422 differential driver | GysE-Q probe
SSI, 24-27bit, binary (standard) or gray | GySE-S probe
output
PROFIBUS DPV0 | GysE-P probe
Ethernet/IP | Gyse-ep2 probe
See all 10 models in list