All Categories

History

Concentration meter Electromagnetic concentration controller-Cem Corporation Co., Ltd.

Price (excluding tax)

Estimate Required

Cem Corporation Co., Ltd.'s Response Status

Response Rate

100.0%

Response Time

16.5hours

Relatively Fast Response


Model Description

■Summary - This is an electromagnetic concentration meter that measures liquids with high conductivity such as strong acids, strong alkalis, and salts using electromagnetic induction. - Hydrochloric acid, sulfuric acid, sodium hydroxide, and sodium chloride can be measured directly by selecting each liquid in the measurement target settings.  ・Many other high concentration liquids can also be measured by selecting CUSTOM and inputting coefficients. ■Features - Can also be used as a high concentration conductivity meter. ・Concentration measurement value (weight %) is displayed in large size on the large LCD display for control alarm output. ・Liquid temperature, lower limit set value, and output status are also displayed on the same screen. The LCD has a backlight. ・Equipped as standard with contact output for alarm, voltage output to which pump can be directly connected, and pulse output for electromagnetic metering pump control. ・Current output for external equipment (4 to 20 mA DC) is also included as standard. - Change settings and calibrate and correct concentration measurements from the front panel. - A sunshade cover is included as standard, and the waterproof structure when installed is equivalent to IP54 for outdoor use. ■Applications ・Concentration control of chemicals such as hydrochloric acid and sodium hydroxide in the chemical industry. ・Integration of each process device. ・Management of salt concentration in scrubbers. ・Other management of liquid concentration.


Model Filter

You can search for other models from each index. The displayed value is the value of the currently selected part number.

Accuracy

Alarm contact output

Change measurement target data

Conductivity range

Correction of measured values

Data to be measured

Display

External input

Operating environment

Power consumption

Power supply

Protective structure

Pulse output

Resolution

Size

Standard accessories

Transmission output

Voltage output

Weight

Measuring range

See all 2 models in list
  • Part Number

    Cm-81

Share this product


530+ people viewing

Last viewed: 5 hours ago


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

Concentration meter Electromagnetic concentration controller Cm-81's performance table

Image Price (excluding tax) Accuracy Alarm contact output Change measurement target data Conductivity range Correction of measured values Data to be measured Display External input Operating environment Power consumption Power supply Protective structure Pulse output Resolution Size Standard accessories Transmission output Voltage output Weight
Concentration meter Electromagnetic concentration controller-Part Number-Cm-81 Available upon quote F.S within ±0.5% (conductivity measurement value) *Repeat error due to pseudo signal 2 points Control method: ON/OFF control Hysteresis width 0.01%~F.S Contact capacity AC240V1A or less (resistive load) Select from 4 types of liquid with touch switch Regarding DATA5 (any liquid), 8 coefficients can be changed with a touch switch 0~1000mS/cm 0~300mS/cm 0~30mS/cm Measured value shift (shift width -1.00%~+1.00%) DATA1 Sodium chloride 0~20% DATA2 Hydrochloric acid 0~15% DATA3 Sulfuric acid 0~25% DATA4 Sodium hydroxide 0~10% DATA5 Arbitrary data Digital LCD touch panel allows you to adjust the brightness of the backlight LED 1 point no-voltage contact signal In the case of ON (short circuit), the control output selected as ON on the interlock setting screen is interlocked and turned OFF on the interlock setting screen. Selected control output operates normally. If OFF (open), normal control. 0~40℃ within 85%RH 10VA (at no load) AC100~240V 50/60pHz Drip-proof structure equivalent to IP54 (when using sunshade cover) Control method: Pulse proportional control (open collector) Concentration 0.01% Temperature 0.1℃ Conductivity 0.1mS/cm 138 (W) × 138 (H) × 174 (D) mm Sunshade cover DC4~20mA Input/output isolation Maximum connected load resistance 500Ω Control method: ON/OFF control Hysteresis width 0.01%~F.S 1 point upper/lower limit alarm output (voltage output): Outputs power supply voltage) Motor load current 0.5A (AC200V) / 1.0A (AC100V) Approximately 2kg

There are 2 models for this product.

Customers who viewed this product also viewed

Reviews shown here are reviews of companies.

See More Conductivity Meters Products

Other products of Cem Corporation Co., Ltd.

Reviews shown here are reviews of companies.


View more products of Cem Corporation Co., Ltd.

About Company Handling This Product

Response Rate

100.0%


Response Time

16.5hrs


Company Review

5.0
  • Japan

Category of this product

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2025 Metoree