Product
Non -destruction / high -speed / automatic judgment non -contact hardness Murascan MURARHandling Company
Pulstech IndustryProduct Image | Part Number | Price (excluding tax) | External dimensions | Hardness | Introduction direction | Irradiation diameter | Measured speed | Measurement target | Sample distance | Voltage/current of X -ray tube | accuracy | output | power supply | weight |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
MURAR |
Available upon quote | Sensor: W108 × L213 × H171 (M M) Power supply: W141 × L279 × H193 (M M) | HV500 or higher, HRC45 or higher is recommended | Vertical to the sample | Φ3 m m (standard) (options φ1 m m, φ5 m m) | 3mm/s, 10㎡ ⇒ 2 minutes (irradiation diameter φ3 m m) | Whole copper | 45 m m ± 1mm from the bottom of the product | CR30KV/1.6ma air cooling | HV ± 15 (equivalent to HRC ± 1) in the above measurement speed | Analog output 0-10V (standard) | AC100 ~ 240V, 50/60Hz | Sensor: Approximately 3.7kg Power Supplies: Approximately 5.3kg |