All Categories
History
Relatively Fast Response
Product
Panel type EC meter CE-32C/CE-32HHandling Company
Cem Corporation Co., Ltd.Categories
Click on the part number for more information about each product
Image | Part Number | Price (excluding tax) | Power supply | Weight | Compatible standards | Compatible sensor | Self-diagnosis function | Repeatability | Relative humidity | Measuring range | Measurement method | Temperature compensation range | Temperature compensation | Temperature sensor specifications | Calibration function | Contact output | Ambient temperature | Transmission output hold function | Transmission output | Sensor input |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
CE-32C |
Available upon quote |
Rated voltage: 100~240VAC, 50/60Hz, 10VA (max) |
Approximately 400g |
CE marking/FCC regulations |
CESL series (Cell constant: Select from 0.01/cm, 0.1/cm, 1.0/cm) |
Sensor diagnosis: Temperature sensor short circuit, temperature sensor disconnection, out of measurement range, converter abnormality |
Within ±0.5% full scale (However, TDS is within ±1.5% full scale) |
20~85% (no condensation) |
Cell constant (/cm) 0.01 0.1 1.0 |
2 electrode method |
0~100℃ |
Standard temperature and temperature coefficient arbitrary setting (Reference temperature: 5~95℃ Temperature coefficient ±5%/℃) Temperature characteristics of NaCl, temperature not compensated |
Resistance temperature detector: 1,000Ω/0℃ |
Electrical conductivity: Cell constant correction coefficient input (parameter input) Temperature: Comparison calibration with reference thermometer TDS: Conversion using arbitrary coefficient (0.30~1.00) |
Number of output points: 2 points (R1, R2) Contact type: Relay contact, SPDT (1c) Contact capacity: AC240V3A, DC30V3A (resistive load) Contact capability: Upper and lower limit operation (ON/OFF control), USP judgment, abnormality alarm, maintenance Select settings from among |
-5~45℃ |
Select from last hold, arbitrary hold, and continuous (however, in maintenance mode, the last hold will be used) |
Number of output points: 1 point DC4~20mA Input/output isolated type Maximum load resistance 900Ω |
1 channel (cell constant: 0.01/cm, 0.1/cm, 1.0/cm) |
|
CE-32H |
Available upon quote |
Rated voltage: 100~240VAC, 50/60Hz, 10VA (max) |
Approximately 400g |
CE marking/FCC regulations |
CESH-05S, CESH-10S, CES-125F (Cell constant: 1.0/cm) |
Sensor diagnosis: Temperature sensor short circuit, temperature sensor disconnection, out of measurement range, converter abnormality |
Within ±0.5% full scale (±1.0% for salinity conversion and 500mS/cm range) |
20~85% (no condensation) |
Electrical conductivity (mS/cm) 0.00~20.00 0.0~200.0 0.0~500.0 (S/m) 0.000~2.000 0.00~20.00 0.00~50.00 |
4 electrode method |
0~100℃ |
Temperature characteristics of ultrapure water (Reference temperature 25℃) Standard temperature and temperature coefficient arbitrary setting (Reference temperature: 5~95℃ Temperature coefficient ±5%/℃) |
Resistance temperature detector: 1,000Ω/0℃ |
Electrical conductivity: Cell constant correction coefficient input (parameter input) Temperature: Comparison calibration with reference thermometer |
Number of output points: 2 points (R1, R2) Contact type: Relay contact, SPDT (1c) Contact capacity: AC240V3A, DC30V3A (resistive load) Contact capacity: Select from upper and lower limit operation (ON/OFF control), abnormal alarm, and maintenance. setting |
-5~45℃ |
Select from last hold, arbitrary hold, and continuous (however, in maintenance mode, the last hold will be used) |
Number of output points: 1 point DC4~20mA Input/output isolated type Maximum load resistance 900Ω |
1 channel (cell constant: 1.0/cm) |