All Categories
History
Relatively Fast Response
Product
Nitrogen gas generator compressor -specific NPS/NPSK seriesHandling Company
ANEST IWATA CorporationCategories
Click on the part number for more information about each product
Image | Part Number | Price (excluding tax) | Nitrogen generating device purity VOL% | Nitrogen generating device generated N㎥/h | Nitrogen generating device discharge pressure MPA | Nitrogen generating device exposure point ℃ or less | Nitrogen generating equipment air entrance | Nitrogen generating device nitrogen gas outlet | Nitrogen generating device PSA control unit power consumption w | Nitrogen generating device oxygen concentration meter | Electric power supply | Phase of electricity | Electric frequency Hz | Raw Air Conditions | Raw air required raw air air volume L/min | Raw air required raw air pressure M/PA | External input / output remote control signal input | External input / output operation response signal output | Other drain exhaust | Other environmental surrounding temperature temperature lower limit ―― Temperature maximum ℃ | Other environmental temperature temperature lower %RH-Temperature maximum RH | Equipment color | Other outer diameter dimensions Wright W x depth L x All height H mm | Other outline weight kg | Raw air compressor output equivalent kw | External input / output external emergency stop signal input | External input / output nitrogen purity reduced signal output | External input / output abnormality / warning signal output |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
NPSK-04-2N |
Available upon quote |
99 |
12.5 |
0.35 |
-55 |
RC3/8 |
RC1/4 |
200 |
L display range: 0-1.999%Measurement range: 0.05-1%O2 accuracy: ± 5%F.S. (25 ° C) |
AC100V |
Single-phase |
50/60 |
Dry air |
35 |
0.65 |
Existence |
Existence |
RC1/4 |
5-40 |
10-80 |
Mansel 5Y8/0.5 |
400x460x850 |
45 |
- | - | - | - |
![]() |
NPSK-04-3N |
Available upon quote |
99.9 |
8.5 |
0.4 |
-55 |
RC3/8 |
RC1/4 |
200 |
L display range: 0-19999PPM measurement range: 50-1000PPMO2 accuracy: ± 5%F.S. (25 ° C) |
AC100V |
Single-phase |
50/60 |
Dry air |
35 |
0.65 |
Existence |
Existence |
RC1/4 |
5-40 |
10-80 |
Mansel 5Y8/0.5 |
400x460x850 |
45 |
- | - | - | - |
![]() |
NPSK-04-4N |
Available upon quote |
99.99 |
5 |
0.45 |
-55 |
RC3/8 |
RC1/4 |
200 |
L display range: 0-19999PPM measurement range: 50-1000PPMO2 accuracy: ± 5%F.S. (25 ° C) |
AC100V |
Single-phase |
50/60 |
Dry air |
35 |
0.65 |
Existence |
Existence |
RC1/4 |
5-40 |
10-80 |
Mansel 5Y8/0.5 |
400x460x850 |
45 |
- | - | - | - |
![]() |
NPSK-07-2N |
Available upon quote |
99 |
26 |
0.35 |
-55 |
RC3/8 |
RC1/4 |
200 |
L display range: 0-1.999%Measurement range: 0.05-1%O2 accuracy: ± 5%F.S. (25 ° C) |
AC100V |
Single-phase |
50/60 |
Dry air |
80 |
0.6-0.8 |
- | - |
RC1/4 |
5-40 |
10-80 |
Mansel 5Y8/0.5 |
480x620x950 |
75 |
- | - | - | - |
![]() |
NPSK-07-3N |
Available upon quote |
99.9 |
17 |
0.4 |
-55 |
RC3/8 |
RC1/4 |
200 |
L display range: 0-19999PPM measurement range: 50-1000PPMO2 accuracy: ± 5%F.S. (25 ° C) |
AC100V |
Single-phase |
50/60 |
Dry air |
80 |
0.6-0.8 |
- | - |
RC1/4 |
5-40 |
10-80 |
Mansel 5Y8/0.5 |
480x620x950 |
75 |
- | - | - | - |
![]() |
NPSK-07-4N |
Available upon quote |
99.99 |
10 |
0.45 |
-55 |
RC3/8 |
RC1/4 |
200 |
L display range: 0-19999PPM measurement range: 50-1000PPMO2 accuracy: ± 5%F.S. (25 ° C) |
AC100V |
Single-phase |
50/60 |
Dry air |
80 |
0.6-0.8 |
- | - |
RC1/4 |
5-40 |
10-80 |
Mansel 5Y8/0.5 |
480x620x950 |
75 |
- | - | - | - |
![]() |
NPSK-12-2n |
Available upon quote |
99 |
38.5 |
0.35 |
-55 |
RC3/8 |
RC1/4 |
- |
L display range: 0-1.999%Measurement range: 0.05-1%O2 accuracy: ± 5%F.S. (25 ° C) |
AC100V |
Single-phase |
50/60 |
Dry air |
120 |
0.6-0.8 |
- | - |
RC1/4 |
- | - |
Mansel 5Y8/0.5 |
600x650x1,300 |
95 |
- | - | - | - |
![]() |
NPSK-12-3N |
Available upon quote |
99.9 |
26 |
0.4 |
-55 |
RC3/8 |
RC1/4 |
- |
L display range: 0-19999PPM measurement range: 50-1000PPMO2 accuracy: ± 5%F.S. (25 ° C) |
AC100V |
Single-phase |
50/60 |
Dry air |
120 |
0.6-0.8 |
- | - |
RC1/4 |
- | - |
Mansel 5Y8/0.5 |
600x650x1,300 |
95 |
- | - | - | - |
![]() |
NPSK-12-4N |
Available upon quote |
99.99 |
15.5 |
0.45 |
-55 |
RC3/8 |
RC1/4 |
- |
L display range: 0-19999PPM measurement range: 50-1000PPMO2 accuracy: ± 5%F.S. (25 ° C) |
AC100V |
Single-phase |
50/60 |
Dry air |
120 |
0.6-0.8 |
- | - |
RC1/4 |
- | - |
Mansel 5Y8/0.5 |
600x650x1,300 |
95 |
- | - | - | - |
![]() |
NPSK-15-2n |
Available upon quote |
99 |
3.3 |
0.5 |
-55 |
RC3/8 |
RC3/8 |
200 |
L display range: 0-1.999%Measurement range: 0.05-1%O2 accuracy: ± 5%F.S. (25 ° C) |
AC100V/AC200V |
Single-phase |
50/60 |
Oil -free dried areas |
165 |
- |
Existence |
Existence |
RC3/8 |
5-40 |
10-80 |
Body: White Door: Pastel Blue |
550x800x950 (not included) |
160 |
1.5 |
Existence |
Existence |
Existence |
Click on the part number for more information about each product
Reviews shown here are reviews of companies.
Reviews shown here are reviews of companies.