Product
Nitrogen gas generator compressor -specific NPS/NPSK seriesHandling Company
ANEST IWATA CorporationCategories
Items marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | Electric frequency Hz | Electric power supply | Equipment color | External input / output abnormality / warning signal output | External input / output external emergency stop signal input | External input / output nitrogen purity reduced signal output | External input / output operation response signal output | External input / output remote control signal input | Nitrogen generating device PSA control unit power consumption w | Nitrogen generating device discharge pressure MPA | Nitrogen generating device exposure point ℃ or less | Nitrogen generating device generated N㎥/h | Nitrogen generating device nitrogen gas outlet | Nitrogen generating device oxygen concentration meter | Nitrogen generating device purity VOL% | Nitrogen generating equipment air entrance | Other drain exhaust | Other environmental surrounding temperature temperature lower limit ―― Temperature maximum ℃ | Other environmental temperature temperature lower %RH-Temperature maximum RH | Other outer diameter dimensions Wright W x depth L x All height H mm | Other outline weight kg | Phase of electricity | Raw Air Conditions | Raw air compressor output equivalent kw | Raw air required raw air air volume L/min | Raw air required raw air pressure M/PA |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
NPSK-04-2N |
Available upon quote | 50/60 | AC100V | Mansel 5Y8/0.5 | - | - | - | Existence | Existence | 200 | 0.35 | -55 | 12.5 | RC1/4 | L display range: 0-1.999%Measurement range: 0.05-1%O2 accuracy: ± 5%F.S. (25 ° C) | 99 | RC3/8 | RC1/4 | 5-40 | 10-80 | 400x460x850 | 45 | Single-phase | Dry air | - | 35 | 0.65 | |
NPSK-04-3N |
Available upon quote | 50/60 | AC100V | Mansel 5Y8/0.5 | - | - | - | Existence | Existence | 200 | 0.4 | -55 | 8.5 | RC1/4 | L display range: 0-19999PPM measurement range: 50-1000PPMO2 accuracy: ± 5%F.S. (25 ° C) | 99.9 | RC3/8 | RC1/4 | 5-40 | 10-80 | 400x460x850 | 45 | Single-phase | Dry air | - | 35 | 0.65 | |
NPSK-04-4N |
Available upon quote | 50/60 | AC100V | Mansel 5Y8/0.5 | - | - | - | Existence | Existence | 200 | 0.45 | -55 | Five | RC1/4 | L display range: 0-19999PPM measurement range: 50-1000PPMO2 accuracy: ± 5%F.S. (25 ° C) | 99.99 | RC3/8 | RC1/4 | 5-40 | 10-80 | 400x460x850 | 45 | Single-phase | Dry air | - | 35 | 0.65 | |
NPSK-07-2N |
Available upon quote | 50/60 | AC100V | Mansel 5Y8/0.5 | - | - | - | - | - | 200 | 0.35 | -55 | 26 | RC1/4 | L display range: 0-1.999%Measurement range: 0.05-1%O2 accuracy: ± 5%F.S. (25 ° C) | 99 | RC3/8 | RC1/4 | 5-40 | 10-80 | 480x620x950 | 75 | Single-phase | Dry air | - | 80 | 0.6-0.8 | |
NPSK-07-3N |
Available upon quote | 50/60 | AC100V | Mansel 5Y8/0.5 | - | - | - | - | - | 200 | 0.4 | -55 | 17 | RC1/4 | L display range: 0-19999PPM measurement range: 50-1000PPMO2 accuracy: ± 5%F.S. (25 ° C) | 99.9 | RC3/8 | RC1/4 | 5-40 | 10-80 | 480x620x950 | 75 | Single-phase | Dry air | - | 80 | 0.6-0.8 | |
NPSK-07-4N |
Available upon quote | 50/60 | AC100V | Mansel 5Y8/0.5 | - | - | - | - | - | 200 | 0.45 | -55 | Ten | RC1/4 | L display range: 0-19999PPM measurement range: 50-1000PPMO2 accuracy: ± 5%F.S. (25 ° C) | 99.99 | RC3/8 | RC1/4 | 5-40 | 10-80 | 480x620x950 | 75 | Single-phase | Dry air | - | 80 | 0.6-0.8 | |
NPSK-12-2n |
Available upon quote | 50/60 | AC100V | Mansel 5Y8/0.5 | - | - | - | - | - | - | 0.35 | -55 | 38.5 | RC1/4 | L display range: 0-1.999%Measurement range: 0.05-1%O2 accuracy: ± 5%F.S. (25 ° C) | 99 | RC3/8 | RC1/4 | - | - | 600x650x1,300 | 95 | Single-phase | Dry air | - | 120 | 0.6-0.8 | |
NPSK-12-3N |
Available upon quote | 50/60 | AC100V | Mansel 5Y8/0.5 | - | - | - | - | - | - | 0.4 | -55 | 26 | RC1/4 | L display range: 0-19999PPM measurement range: 50-1000PPMO2 accuracy: ± 5%F.S. (25 ° C) | 99.9 | RC3/8 | RC1/4 | - | - | 600x650x1,300 | 95 | Single-phase | Dry air | - | 120 | 0.6-0.8 | |
NPSK-12-4N |
Available upon quote | 50/60 | AC100V | Mansel 5Y8/0.5 | - | - | - | - | - | - | 0.45 | -55 | 15.5 | RC1/4 | L display range: 0-19999PPM measurement range: 50-1000PPMO2 accuracy: ± 5%F.S. (25 ° C) | 99.99 | RC3/8 | RC1/4 | - | - | 600x650x1,300 | 95 | Single-phase | Dry air | - | 120 | 0.6-0.8 | |
NPSK-15-2n |
Available upon quote | 50/60 | AC100V/AC200V | Body: White Door: Pastel Blue | Existence | Existence | Existence | Existence | Existence | 200 | 0.5 | -55 | 3.3 | RC3/8 | L display range: 0-1.999%Measurement range: 0.05-1%O2 accuracy: ± 5%F.S. (25 ° C) | 99 | RC3/8 | RC3/8 | 5-40 | 10-80 | 550x800x950 (not included) | 160 | Single-phase | Oil -free dried areas | 1.5 | 165 | - |
Click on the part number for more information about each product