Space saving and rapid gas concentration recovery Single Rower Incubator SD830
Astec Co., Ltd.
About This Product
Multi -gas Incubator that can be placed at hand
■ Space saving and rapid gas concentration return
・ It is a space -saving multi -gas incubator that does not choose a layout. (W310mm x D315mm x H190mm)
・ Compared to our AP series, the content is reduced by 96%and the installation area is reduced by 35%.
・ It is possible to reduce the culture environment change at the time of opening and closing by small size.
・ Return to the set concentration in about 10 minutes after opening the door. (CO2 5%, O2 5% door 20 seconds opening and closing)
・ Two -stage and three -stage correspondence are possible according to the layout.
■ Compatible with humidification/humidification
Maintain 95%or more humidity during humidification. It maintains a higher humidity than a normal air jacket CO2/multi -gas incubator, including other companies, to prevent changes in osmotic pressure and evaporation of medium. CO2 uses an IR sensor, and O2 has a galvani sascer. The specifications have low drift due to auto calibration. It also supports humidified culture and can reduce contamination risk.
■ New separated separate door
By dividing the door opening and closing (separate), the temperature and gas change at the time of opening and closing, as well as individual management, are reduced. With this unique feature, the identification of each patient is separated, the impact on other patients can be reduced, and it can be accessed in half of the chamber. We are particular about the optimal environment for cells.
■ Energy saving design. In case of emergency, it also supports email notification system/earthquake/fall prevention measures.
Up to 80W, 18W at stable, and can be operated with energy saving. Depending on the usage environment, the energy saving specification is safe when installing multiple units or when connecting to other devices. It is possible to produce a fall prevention bracket as an earthquake countermeasure and propose the installation position. You can output real -time data alarms with temperature and gas concentration outside.
We can connect and connect (CISAS/V4, KR3000, Lab Keeper), and manage real -time data to email, notification to mobile phones, and real -time data.
■ Simplification
It is easy to remove the chamber and can easily clean it. Auto craved drawers can be completely removed. The drawer base is made of aluminum and can be easily cleaned because of a curved design. * Because it is made of aluminum, there is a deterioration of discoloration.
-
-
Product
Space saving and rapid gas concentration recovery Single Rower Incubator SD830