Contract the sample temperature accurately thermal cycla Geneatlas G/S series-G02
Contract the sample temperature accurately thermal cycla Geneatlas G/S series-Astec Co., Ltd.

Contract the sample temperature accurately thermal cycla Geneatlas G/S series
Astec Co., Ltd.


About This Product

■ Product points Thermal Cycla GENEATLAS is a domestic machine with excellent performance ・ Accurate temperature control ・ High operability and visibility ・ Equipped with a gradient function (G type only) ・ Log data acquisition and interface ・ Sample holder can be changed (optional) ■ Accurate temperature control Accurately control the sample temperature by digital PID control by a microcessor. Temperature control accuracy ± 0.1 ℃ ■ High operability and visibility A light touch operation is possible by adopting the new TFT color LCD touch panel. Furthermore, a large screen 5.7 inch high resolution TFT color LCD provides high visibility with table display and graph display. ■ Equipped with a gradient function (G type only) Equipped with a maximum ± 30 ° C, 12 -stage gravility function. It is possible to examine the annealing temperature conditions. ■ acquisition of Log data and interface It is possible to save use history, operation history, and error history with the memory card. In addition, it is possible to move protocol movement between devices (CSV), edit on a PC, and export Log data (TXT). ■ Sample holder can be changed (optional) It is possible to remove and replace the sample holder. 0.2ml x 96, 0.5ml x 54, slide glass, 384 plates

  • Product

    Contract the sample temperature accurately thermal cycla Geneatlas G/S series




*Please note that we may not be able to accommodate sample requests.

4 Models of Contract the sample temperature accurately thermal cycla Geneatlas G/S series

Items marked with have different values ​​depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Change sample holder Cooling method Cover heater control External dimensions Gradient setting temperature Heating cooling time setting range Indicator Interface Maximum cooling speed Maximum cycle Maximum heating speed Number of program files Number of reaction temperature steps Response time setting range Temperature control accuracy Temperature control method Temperature control range Temperature distribution between halls The number of samples function power supply specification weight
Contract the sample temperature accurately thermal cycla Geneatlas G/S series-Part Number-G02

G02

Available upon quote 0.2ml x 96, 0.5ml x 54, slide glass, 384 plate change possible Heated cooling/cover part ceramic heater by Solidsted Module Constant temperature, block interlocking, OFF W220 x D450 x H250mm Up to 30 ° C 1 second to 9 hours 59 minutes 59 seconds 5.7 inch TFT color LCD touch panel Memory card board 3.0 ° C/second 99 cycle/segment 3.5 ℃/second Up to 240 files Up to 25 steps (5 steps/cycle x 5 segments) 1 second to 59 minutes 59 seconds, Hold, Infinity ± 0.1 ℃ PID control by microcessor 4.0 ° C ~ 99.9 ℃ ± 0.5 ° C or less 0.2ml x 96 bottles Self -diagnostic function, end time display, reaction volume setting AC100V 50/60Hz 5A Gradient specifications 11
Contract the sample temperature accurately thermal cycla Geneatlas G/S series-Part Number-G05

G05

Available upon quote 0.2ml x 96, 0.5ml x 54, slide glass, 384 plate change possible Heated cooling/cover part ceramic heater by Solidsted Module Constant temperature, block interlocking, OFF W220 x D450 x H250mm Up to 30 ° C 1 second to 9 hours 59 minutes 59 seconds 5.7 inch TFT color LCD touch panel Memory card board 2.5 ℃/second 99 cycle/segment 3.0 ° C/second Up to 240 files Up to 25 steps (5 steps/cycle x 5 segments) 1 second to 59 minutes 59 seconds, Hold, Infinity ± 0.1 ℃ PID control by microcessor 4.0 ° C ~ 99.9 ℃ ± 0.5 ° C or less 0.5ml x 54 bottles Self -diagnostic function, end time display, reaction volume setting AC100V 50/60Hz 5A Gradient specifications 11
Contract the sample temperature accurately thermal cycla Geneatlas G/S series-Part Number-S02

S02

Available upon quote 0.2ml x 96, 0.5ml x 54, slide glass, 384 plate change possible Heated cooling/cover part ceramic heater by Solidsted Module Constant temperature, block interlocking, OFF W220 x D450 x H250mm Up to 30 ° C 1 second to 9 hours 59 minutes 59 seconds 5.7 inch TFT color LCD touch panel Memory card board 3.0 ° C/second 99 cycle/segment 3.5 ℃/second Up to 240 files Up to 25 steps (5 steps/cycle x 5 segments) 1 second to 59 minutes 59 seconds, Hold, Infinity ± 0.1 ℃ PID control by microcessor 4.0 ° C ~ 99.9 ℃ ± 0.5 ° C or less 0.2ml x 96 bottles Self -diagnostic function, end time display, reaction volume setting AC100V 50/60Hz 5A Standard specification 11
Contract the sample temperature accurately thermal cycla Geneatlas G/S series-Part Number-S05

S05

Available upon quote 0.2ml x 96, 0.5ml x 54, slide glass, 384 plate change possible Heated cooling/cover part ceramic heater by Solidsted Module Constant temperature, block interlocking, OFF W220 x D450 x H250mm Up to 30 ° C 1 second to 9 hours 59 minutes 59 seconds 5.7 inch TFT color LCD touch panel Memory card board 2.5 ℃/second 99 cycle/segment 3.0 ° C/second Up to 240 files Up to 25 steps (5 steps/cycle x 5 segments) 1 second to 59 minutes 59 seconds, Hold, Infinity ± 0.1 ℃ PID control by microcessor 4.0 ° C ~ 99.9 ℃ ± 0.5 ° C or less 0.5ml x 54 bottles Self -diagnostic function, end time display, reaction volume setting AC100V 50/60Hz 5A Standard specification 11

Click on the part number for more information about each product

Customers who viewed this product also viewed

Other products of Astec Co., Ltd.


View more products of Astec Co., Ltd.

About Company Handling This Product

Astec Co., Ltd.

  • Japan
  • Since 1978