Product
On-site PH/ORP meter FEB-102-PHHandling Company
Shinko Technos Co., Ltd.Categories
Click on the part number for more information about each product
Image | Part Number | Price (excluding tax) | Input 1 | Entering 2 | Repetition | Linearness | Temperature instruction accuracy | Input sampling cycle | Time accuracy | EVT output (2 points) 1 | EVT output (2 points) 2 | EVT output (2 points) 3 | Calibration function | Transmission output 1, 2-1 | Transmission output 1, 2-2 | Self -diagnostic function | Ambient temperature | Peripheral humidity | power supply | power consumption | Mounting method | Case, panel | Drip -proof / dustproof structure | Conformity standard | External dimensions | mass | Serial communication (Options: C5) | Serial communication (option: C5) cable length | Serial communication (option: C5) communication line | Serial communication (Options: C5) Communication method | Serial communication (option: C5) communication speed | Serial communication (option: C5) synchronous method |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
FEB-102-pH, CS |
Available upon quote |
PH composite electrode sensor (PH sensor: JIS Z8802 compliant, temperature element: CU500/25 ° C, PT100 or PT1000) |
ORP composite electrode sensor (temperature element: CU500/25 ° C, PT100 or PT1,000) |
PH meter: ± 0.05PH, ORP meter: within ± 5mv (in equivalent input) |
PH meter: ± 0.05PH, ORP meter: within ± 5mv (in equivalent input) |
± 1 ℃ |
125 MS (2 input) |
Within ± 1%for the set time |
・ Setting accuracy: Same as instruction accuracy |
・ Control capacity: 3A 250V AC (resistance load), 1A 250V AC (induced load COSφ = 0.4) |
・ Operation ON delay timer: 0 to 10000 seconds |
・ PH calibration 2 points Automatic proofreading or manual proofreading, type of standard solution PH2, 4, 7, 9, 10 (JIS) ・ Temperature school regular (1 point) |
PH, temperature, ORP value, and MV are converted to analog amount for each input sampling and output in current. (The decimal position is fixed regardless of the decimal position selection) |
・ Dusive ability: 12000 ・ Current: 4 ~ 20mA DC (maximum load resistance 550Ω) ・ Output accuracy: within ± 0.3%of transmission output span |
Motor the CPU with a watchdog timer and make the instrument into an initial state in the event of an abnormality. |
-20 ~ 50 ° C (how to adapt to the instruction accuracy at 0 to 50 ° C and avoid direct sunlight) |
35 ~ 95%RH (but not condensation) |
100 ~ 240 V AC 50/60 Hz tolerance fluctuation range: 85 ~ 264 v AC |
Approximately 9 VA |
Wall installation method |
・ Case: Polycarbonate color: Metallic gray |
IP65 |
ROHS command support |
W239.5xh190XD75mm |
Approximately 950g |
Perform the following operations from the external computer.・ Reading and setting of various set values ・ Change, adjustment of functions / functions of ORP or status |
1.2 km (maximum) Cable resistance within 50Ω (end resistance: None or 120Ω or more on both sides) |
EIA RS-485 compliant |
Half double communication |
Select 9600, 19200, 38400 BPS by key operation |
Toning synchronization |
|
FEB-102-PH, EVT3 |
Available upon quote |
PH composite electrode sensor (PH sensor: JIS Z8802 compliant, temperature element: CU500/25 ° C, PT100 or PT1000) |
ORP composite electrode sensor (temperature element: CU500/25 ° C, PT100 or PT1000) |
PH meter: ± 0.05PH, ORP meter: within ± 5mv (in equivalent input) |
PH meter: ± 0.05PH, ORP meter: within ± 5mv (in equivalent input) |
± 1 ℃ |
125 MS (2 input) |
Within ± 1%for the set time |
・ Setting accuracy: Same as instruction accuracy |
・ Control capacity: 3A 250V AC (resistance load), 1A 250V AC (induced load COSφ = 0.4) |
・ Operation ON delay timer: 0 to 10000 seconds |
・ PH calibration 2 points Automatic proofreading or manual proofreading, type of standard solution pH2, 4, 7, 9, 10 (JIS) |
PH, temperature, ORP value, and MV are converted to analog amount for each input sampling and output in current. (The decimal position is fixed regardless of the decimal position selection) |
・ Resolution: 12,000 |
Motor the CPU with a watchdog timer and make the instrument into an initial state in the event of an abnormality. |
-20 ~ 50 ° C (how to adapt to the instruction accuracy at 0 to 50 ° C and avoid direct sunlight) |
35 ~ 95%RH (but not condensation) |
100 ~ 240 V AC 50/60 Hz tolerance fluctuation range: 85 ~ 264 v AC |
Approximately 9 VA |
Wall installation method |
・ Case: Polycarbonate color: Metallic gray |
IP65 |
ROHS command support |
W239.5xh190XD75mm |
Approximately 950g |
Perform the following operations from the external computer. |
1.2 km (maximum) Cable resistance within 50Ω (end resistance: None or 120Ω or more on both sides) |
EIA RS-485 compliant |
Half double communication |
Select 9600, 19200, 38400 BPS by key operation |
Toning synchronization |
|
FEB-102-PH, EVT4 |
Available upon quote |
PH composite electrode sensor (PH sensor: JIS Z8802 compliant, temperature element: CU500/25 ° C, PT100 or PT1000) |
ORP composite electrode sensor (temperature element: CU500/25 ° C, PT100 or PT1000) |
PH meter: ± 0.05PH, ORP meter: within ± 5mv (in equivalent input) |
PH meter: ± 0.05PH, ORP meter: within ± 5mv (in equivalent input) |
± 1 ℃ |
125 MS (2 input) |
Within ± 1%for the set time |
・ Setting accuracy: Same as instruction accuracy |
・ Control capacity: 3A 250V AC (resistance load), 1A 250V AC (induced load COSφ = 0.4) |
・ Operation ON delay timer: 0 to 10000 seconds |
・ PH calibration 2 points Automatic proofreading or manual proofreading, type of standard solution pH2, 4, 7, 9, 10 (JIS) |
PH, temperature, ORP value, and MV are converted to analog amount for each input sampling and output in current. (The decimal position is fixed regardless of the decimal position selection) |
・ Dusive ability: 12000 ・ Current: 4 ~ 20mA DC (maximum load resistance 550Ω) ・ Output accuracy: within ± 0.3%of transmission output span |
Motor the CPU with a watchdog timer and make the instrument into an initial state in the event of an abnormality. |
-20 ~ 50 ° C (how to adapt to the instruction accuracy at 0 to 50 ° C and avoid direct sunlight) |
35 ~ 95%RH (but not condensation) |
100 ~ 240 V AC 50/60 Hz tolerance fluctuation range: 85 ~ 264 v AC |
Approximately 9 VA |
Wall installation method |
・ Case: Polycarbonate color: Metallic gray |
IP65 |
ROHS command support |
W239.5xh190XD75mm |
Approximately 950g |
Perform the following operations from the external computer. |
1.2 km (maximum) Cable resistance within 50Ω (end resistance: None or 120Ω or more on both sides) |
EIA RS-485 compliant |
Half double communication |
Select 9600, 19200, 38400 BPS by key operation |
Toning synchronization |