On-site PH/ORP meter FEB-102-PH-Shinko Technos Co., Ltd.

FEB-102-PH, EVT3 | On-site PH/ORP meter FEB-102-PH
Shinko Technos Co., Ltd.


Price (excluding tax)

Estimate Required


Model Description

・ Input number: 2 points ・ Input: PH composite electrode sensor (CU500/25 ° C, PT100 or PT1000), ORP composite electrode sensor ・ Power supply voltage: 100-240V AC ・ Options: EVT3 output (contact output 3)


Model Filter

You can search for other models from each index. The displayed value is the value of the currently selected part number.

Ambient temperature

Calibration function

Case, panel

Conformity standard

Drip -proof / dustproof structure

EVT output (2 points) 1

EVT output (2 points) 2

EVT output (2 points) 3

Entering 2

External dimensions

Input 1

Input sampling cycle

Linearness

Mounting method

Peripheral humidity

Repetition

Self -diagnostic function

Serial communication (Options: C5)

Serial communication (Options: C5) Communication method

Serial communication (option: C5) cable length

Serial communication (option: C5) communication line

Serial communication (option: C5) communication speed

Serial communication (option: C5) synchronous method

Temperature instruction accuracy

Time accuracy

Transmission output 1, 2-1

Transmission output 1, 2-2

mass

power consumption

power supply

See all 3 models in list
  • Part Number

    FEB-102-PH, EVT3




*Please note that we may not be able to accommodate sample requests.

On-site PH/ORP meter FEB-102-PH FEB-102-PH, EVT3's performance table

Items marked with have different values ​​depending on the model number.

Product Image Price (excluding tax) Ambient temperature Calibration function Case, panel Conformity standard Drip -proof / dustproof structure EVT output (2 points) 1 EVT output (2 points) 2 EVT output (2 points) 3 Entering 2 External dimensions Input 1 Input sampling cycle Linearness Mounting method Peripheral humidity Repetition Self -diagnostic function Serial communication (Options: C5) Serial communication (Options: C5) Communication method Serial communication (option: C5) cable length Serial communication (option: C5) communication line Serial communication (option: C5) communication speed Serial communication (option: C5) synchronous method Temperature instruction accuracy Time accuracy Transmission output 1, 2-1 Transmission output 1, 2-2 mass power consumption power supply
On-site PH/ORP meter FEB-102-PH-Part Number-FEB-102-PH, EVT3 Available upon quote -20 ~ 50 ° C (how to adapt to the instruction accuracy at 0 to 50 ° C and avoid direct sunlight) ・ PH calibration 2 points Automatic proofreading or manual proofreading, type of standard solution pH2, 4, 7, 9, 10 (JIS) ・ Temperature school regular (1 point) ・ Case: Polycarbonate color: Metallic gray ・ Panel: Membrane sheet ROHS command support IP65 ・ Setting accuracy: Same as instruction accuracy ・ Output operation: P operation proportional belt other than 0, when the ON/OFF operation proportional belt is set to 0. ・ Relay contact 1A ・ Control capacity: 3A 250V AC (resistance load), 1A 250V AC (induced load COSφ = 0.4) ・ Electrical life: 100,000 times ・ Operation ON delay timer: 0 to 10000 seconds ・ Operation OFF delay timer: 0 to 10000 seconds ORP composite electrode sensor (temperature element: CU500/25 ° C, PT100 or PT1000) W239.5xh190XD75mm PH composite electrode sensor (PH sensor: JIS Z8802 compliant, temperature element: CU500/25 ° C, PT100 or PT1000) 125 MS (2 input) PH meter: ± 0.05PH, ORP meter: within ± 5mv (in equivalent input) Wall installation method 35 ~ 95%RH (but not condensation) PH meter: ± 0.05PH, ORP meter: within ± 5mv (in equivalent input) Motor the CPU with a watchdog timer and make the instrument into an initial state in the event of an abnormality. Perform the following operations from the external computer. ・ Read and set various set values ・ Reading pH, temperature, ORP value or state ・ Change and adjust function Half double communication 1.2 km (maximum) Cable resistance within 50Ω (end resistance: None or 120Ω or more on both sides) EIA RS-485 compliant Select 9600, 19200, 38400 BPS by key operation Toning synchronization ± 1 ℃ Within ± 1%for the set time PH, temperature, ORP value, and MV are converted to analog amount for each input sampling and output in current. (The decimal position is fixed regardless of the decimal position selection) ・ Resolution: 12,000 ・ Current: 4 ~ 20mA DC (maximum load resistance 550Ω) ・ Output accuracy: within ± 0.3%of transmission output span Approximately 950g Approximately 9 VA 100 ~ 240 V AC 50/60 Hz tolerance fluctuation range: 85 ~ 264 v AC

There are 3 models for this product.

Customers who viewed this product also viewed

Other products of Shinko Technos Co., Ltd.