Product
Automatic whirlpool exploration device Elotest PL600Handling Company
Roman JapanProduct Image | Part Number | Price (excluding tax) | Advanced Plus license | Advanced Plus license channel option | Advanced license | Advanced license channel option | Basic license | Basic unit technical data | Built -in I/O processor | Cancer protection grade | Digital signal processing | Inspection frequency | Remote control function / PC software | Screenshot function | Sensor connection | Sensor input | depth | height | weight | width |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Elotest PL600 |
Available upon quote | All functions included in the "Advanced" license | High -speed multiple frequency selection (multiple lots, multiple batch selections) and harmonics analysis, others | All functions included in the "Basic" license | Up to 64 virtual sensors can be controlled by one channel, others | All recessed signal band and complete (100kHz) signal quality. One test parameter set for each channel |
Function modules can be added to up to 16 slots Additional module type: Inspection channel module CHM600 (one in the basic unit), etc. |
Equipped with high -speed I/O processor on the basic unit Shift registers, end supplements, FIFO functions, and various I/O functions are possible |
IP30 |
High -performance signal processing by FPGA Digital sine wave generator 10Hz -12MHz Two different digital recovery stages Digital signal processing |
10Hz to 12MHz Driver output +/- 10vs, up to 1,000mA Measurement and control of sensor current Voltage / current control operation management |
Remote control using a full HD external touch panel from a remote distance (up to 100m). Remote control and remote maintenance using PC (Windows / Linux / Mac) and TCP / IP | 1,280 x 800 pixels, 10.1 -inch IPS TFT LCD display. HDMI can connect to external Full HD monitor (touch screen operation can be operated simultaneously with USB) |
26 -pin HD SUB connector (compatible with all sensors of Elotest PL500) Can connect a sensor ray with a built -in sensor per channel |
2 input channels in each module Different circuit CMRR is 90db Immediate detection of disconnection by constant monitoring of receipt |
375mm + 35mm |
77 mm (4HU) (Note 1) (Note 1) complies with EIA-310-D, Din 41494 |
10.5kg (channel basic unit) | 82.6mm (19 inch) |