■ It is a controller that achieves a digital output (parallel) with a minimal resolution of 1 μm of the magnet position, and allows analog output of a position or speed (option) at the same time. ・ High -functional digital output controller parallel output (binary/gray), SSI output and A/B phase pulse output can be added as optional, high -speed sampling, auto calibration, GYHC analog controller is output at the same time. ・ Optional SSI and Inclumental Output can be added. (If you need only parallel output, please choose "GYDC-S1".) ・ Use two magnets to output the distance between 2 points and each position. ・ Optional high -speed sampling and PNP output are also possible. -The optional device (with software) (model: GPM) allows the customer to adjust the zero/full scale point, and the decomposition ability and the output direction can be changed. ・ Noise cancellation function ・ GPM setting ・ Auto calibration compatible ■ Auto calibration When combined with auto-calibration-compatible probes (GYSE-R, GYMR6, GYKMR, GYRHP-MR6), the gaps generated at the time of sensor (error due to individual differences in the sensor) are automatically eliminated, so compatibility. You can increase it. * Accuracy is applied to a sensor with an effective stroke of 300mm or more. A sensor of less than 300mm is equivalent to a 300mm sensor specification. * 1 Can be changed to gray by switch * 2 TR ON: Output "0" * 3 Prove: Gyse-R, GYCRS, GYMR5, GYMR6, GYKMR, GYRHP-MR6, GYFRS, EX-GYDT-RS connection * 4 Prove: GYGS, GYMS, GYPM, GYPMR, GYCRP, GYHR, GYHTR, EX-GYDS-RP, IGY4, Gype2K connection * 5 Cable disconnection and magnet * 6 The sampling frequency can be speeded up to 3.75kHz as an option. However, it depends on the total length of the rod, and the current consumption is different.
You can search for other models from each index. The displayed value is the value of the currently selected part number.
Alarm output
Bearing pressure
Operating temperature limit
Optional Accessories
Position output (OUT1) (OUT2: Option)
Sampling frequency
Save temperature range
Speed output (OUT2) (optional)
Supply power supply
Temperature characteristics
resolution
Speed output (VEL) (optional)
Position output
I/O occupied number
Internal power consumption
Number of location detection axes
cable length
function
Part Number
GYDC-05 Digital controllerProduct
Magnetic distortion linear sensor GY series that measures straight line displacement [Controller]Handling Company
SANTEST CO., LTDCategories
Image | Price (excluding tax) | Alarm output | Operating temperature limit | Optional Accessories | Position output | Position output (OUT1) (OUT2: Option) | Sampling frequency | Save temperature range | Speed output (OUT2) (optional) | Supply power supply | Temperature characteristics | resolution |
---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
Available upon quote | Open collector 0.1a 30VDC ( * 5) | 0 ℃ ~+65 ℃ | GPM setting device | Parallel, binary ( * 1), negative argument ( * 2) (Options: Added SSI or A/B phase pulse output) (Digital 24bit) | (Analog) 0 ~ 10V (load current MAX.5MA, load resistance min.2kΩ) or 4 ~ 20mA (load resistance max.500Ω) | Standard 1kHz (up to 1,300mm long rod) | -20 ℃ ~+75 ℃ | ± 10V or 4 ~ 20mA (analog) | Standard:+24VDC ± 5% (150mA or less) | ± 10ppmfs/℃ or less | (Digital) Standard 0.01mm (minimum 0.001mm) ( * 3) 0.1mm ( * 4), (analog) 16bit (1/65,536) ( * 3) 0.01%or less ( * 4) |