All Categories
History
Price (excluding tax)
Response Rate
100.0%
Response Time
4.0hours
Very Fast Response
■ High accuracy/high -performance analog output controller. 2ch output, speed output, 1ch output between 2 points, 2ch output of each of 2 points, high -speed sampling, auto calibration ・ Digital processing of height resolution is performed inside the controller, and this location data is converted to analog and outputs. For this reason, high -solutions can be higher than before (depending on the combination probe). Speed output is also possible with options. ・ You can use two magnets to output the distance between 2 points and each position. ・ Din rails that are easy to remove are used for the mounting of the product. ・ The output adjustment method of the analog output is a tooguru switch system on the front panel, so it is easy to adjust. -The optional device (with software) (model: GPM) allows you to adjust the zero/full scale point and change the output direction. ・ Noise cancellation function ・ GPM setting ・ Auto calibration compatible ■ Auto calibration When combined with auto-calibration-compatible probes (GYSE-R, GYMR6, GYKMR, GYRHP-MR6), the gaps generated at the time of sensor (error due to individual differences in the sensor) are automatically eliminated, so compatibility. You can increase it. * Accuracy is applied to a sensor with an effective stroke of 300mm or more. A sensor of less than 300mm is equivalent to a 300mm sensor specification. * First probe connection: GYMR6, GYSE-R, GYCRS, GYMR5, GYFRS, GYKMR, GYRHP-MR6, EX-GYDT-RS connection * 2: When connecting to the next probe: Gyms, Gygs, Gypm, Gype2k, GYPMR, GYCRP, GYHTR, GYHR, EX-GYDS-RP, when connecting * 3 Cable disconnection and magnet * 4 model ⑥ Additional analog output options are 170mA. * 5 Sampling frequency can be speeded up to 3.75kHz by option. However, it depends on the total length of the rod, and the current consumption is different.
You can search for other models from each index. The displayed value is the value of the currently selected part number.
Alarm output
Bearing pressure
Operating temperature limit
Optional Accessories
Position output (OUT1) (OUT2: Option)
Sampling frequency
Save temperature range
Speed output (OUT2) (optional)
Supply power supply
Temperature characteristics
resolution
Speed output (VEL) (optional)
Position output
I/O occupied number
Internal power consumption
Number of location detection axes
cable length
function
Part Number
GYHC analog controllerProduct
Magnetic distortion linear sensor GY series that measures straight line displacement [Controller]Handling Company
SANTEST CO., LTDCategories
Image | Price (excluding tax) | Alarm output | Bearing pressure | Operating temperature limit | Optional Accessories | Position output (OUT1) (OUT2: Option) | Sampling frequency | Save temperature range | Speed output (OUT2) (optional) | Supply power supply | Temperature characteristics | resolution |
---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
Available upon quote | Open collector 0.1a 30VDC ( * 3) | 35MPa (Problod Department) | 0 ℃ ~+65 ℃ | GPM setting device | 0 ~ 10V (load current MAX.5mA, load resistance min.2kΩ) or 4 ~ 20mA (load resistance max.500Ω) | Standard 1kHz (up to 1,300mm stroke) | -20 ℃ ~+85 ℃ | ± 10V or 4 ~ 20ma | Standard: + 24VDC ± 2V (150mA or less) ( * 4), Options: + 15VDC, + 12VDC, ± 15VDC | ± 10ppmfs/℃ or less | 16bit (1/65,336) ( * 1), 0.01%or less ( * 2) |
Reviews shown here are reviews of companies.
Reviews shown here are reviews of companies.