Ambient temperature
Calibration function
Compatible sensor
Compatible standards
Contact output
Measurement method
Measuring range
Power supply
Relative humidity
Repeatability
Self-diagnosis function
Sensor input
Temperature compensation
Temperature compensation range
Temperature sensor specifications
Transmission output
Transmission output hold function
Weight
Part Number
CE-32HHandling Company
Cem Corporation Co., Ltd.Categories
Image | Price (excluding tax) | Ambient temperature | Calibration function | Compatible sensor | Compatible standards | Contact output | Measurement method | Measuring range | Power supply | Relative humidity | Repeatability | Self-diagnosis function | Sensor input | Temperature compensation | Temperature compensation range | Temperature sensor specifications | Transmission output | Transmission output hold function | Weight |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
Available upon quote | -5~45℃ | Electrical conductivity: Cell constant correction coefficient input (parameter input) Temperature: Comparison calibration with reference thermometer | CESH-05S, CESH-10S, CES-125F (Cell constant: 1.0/cm) | CE marking/FCC regulations | Number of output points: 2 points (R1, R2) Contact type: Relay contact, SPDT (1c) Contact capacity: AC240V3A, DC30V3A (resistive load) Contact capacity: Select from upper and lower limit operation (ON/OFF control), abnormal alarm, and maintenance. setting | 4 electrode method | Electrical conductivity (mS/cm) 0.00~20.00 0.0~200.0 0.0~500.0 (S/m) 0.000~2.000 0.00~20.00 0.00~50.00 *200.0mS/cm and 20.00S/m ranges can be measured up to ±3.5% with a standard temperature of 25℃ and temperature coefficient can be set arbitrarily. *500.0mS/cm, 50.00S/m range can be measured without standard compensation Seawater salinity conversion: 0.00~4.00% NaCl salinity conversion: 0.0~20.0% Temperature: 0~100℃ (No decimal point, 1 digit, 2 (Digit selection display possible) | Rated voltage: 100~240VAC, 50/60Hz, 10VA (max) | 20~85% (no condensation) | Within ±0.5% full scale (±1.0% for salinity conversion and 500mS/cm range) | Sensor diagnosis: Temperature sensor short circuit, temperature sensor disconnection, out of measurement range, converter abnormality | 1 channel (cell constant: 1.0/cm) | Temperature characteristics of ultrapure water (Reference temperature 25℃) Standard temperature and temperature coefficient arbitrary setting (Reference temperature: 5~95℃ Temperature coefficient ±5%/℃) | 0~100℃ | Resistance temperature detector: 1,000Ω/0℃ | Number of output points: 1 point DC4~20mA Input/output isolated type Maximum load resistance 900Ω | Select from last hold, arbitrary hold, and continuous (however, in maintenance mode, the last hold will be used) | Approximately 400g |
Reviews shown here are reviews of companies.
Reviews shown here are reviews of companies.
Response Rate
100.0%
Response Time
16.5hrs
Company Review
5.0