All Categories
History
Price (excluding tax)
Relatively Fast Response
You can search for other models from each index. The displayed value is the value of the currently selected part number.
Ambient temperature
Calibration function
Compatible sensor
Compatible standards
Contact output
Measurement method
Measuring range
Power supply
Relative humidity
Repeatability
Self-diagnosis function
Sensor input
Temperature compensation
Temperature compensation range
Temperature sensor specifications
Transmission output
Transmission output hold function
Weight
Part Number
CE-32CHandling Company
Cem Corporation Co., Ltd.Categories
Image | Price (excluding tax) | Ambient temperature | Calibration function | Compatible sensor | Compatible standards | Contact output | Measurement method | Measuring range | Power supply | Relative humidity | Repeatability | Self-diagnosis function | Sensor input | Temperature compensation | Temperature compensation range | Temperature sensor specifications | Transmission output | Transmission output hold function | Weight |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
Available upon quote | -5~45℃ | Electrical conductivity: Cell constant correction coefficient input (parameter input) Temperature: Comparison calibration with reference thermometer TDS: Conversion using arbitrary coefficient (0.30~1.00) | CESL series (Cell constant: Select from 0.01/cm, 0.1/cm, 1.0/cm) | CE marking/FCC regulations | Number of output points: 2 points (R1, R2) Contact type: Relay contact, SPDT (1c) Contact capacity: AC240V3A, DC30V3A (resistive load) Contact capability: Upper and lower limit operation (ON/OFF control), USP judgment, abnormality alarm, maintenance Select settings from among | 2 electrode method | Cell constant (/cm) 0.01 0.1 1.0 Electrical conductivity (µS/cm) 2.000/20.00 20.00/200.0 200.0/2,000 (mS/m) 0.2000/2.000 2.000/20.00 20.00/200.0 TDS conversion (mg/L) 2.00/20.0 20.0/200 200/2,000 Temperature: 0~100℃ (No decimal point, 1 digit, 2 digit selection display possible) | Rated voltage: 100~240VAC, 50/60Hz, 10VA (max) | 20~85% (no condensation) | Within ±0.5% full scale (However, TDS is within ±1.5% full scale) | Sensor diagnosis: Temperature sensor short circuit, temperature sensor disconnection, out of measurement range, converter abnormality | 1 channel (cell constant: 0.01/cm, 0.1/cm, 1.0/cm) | Standard temperature and temperature coefficient arbitrary setting (Reference temperature: 5~95℃ Temperature coefficient ±5%/℃) Temperature characteristics of NaCl, temperature not compensated | 0~100℃ | Resistance temperature detector: 1,000Ω/0℃ | Number of output points: 1 point DC4~20mA Input/output isolated type Maximum load resistance 900Ω | Select from last hold, arbitrary hold, and continuous (however, in maintenance mode, the last hold will be used) | Approximately 400g |
Reviews shown here are reviews of companies.
Reviews shown here are reviews of companies.
Response Rate
100.0%
Response Time
16.5hrs
Company Review
5.0