Torque sensor T40FMHandling Company
Hottinger Brüel & KjærCategories
Image | Part Number | Price (excluding tax) | Accuracy class | Power supply Current consumption | Power supply Maximum cable length | Power supply Rated power supply (protected low voltage) | Power supply Rating (nominal) Current consumption | Torque measurement frequency output delay time | Torque measurement frequency output Load resistance (terminal resistance) | Torque measurement frequency output Load resistance | Torque measurement frequency output Measurement frequency range | Torque measurement frequency output Standard deviation of repeatability | Torque measurement frequency output Maximum conversion range | Torque measurement frequency output Sensitivity tolerance | Torque measurement frequency output Effect on sensitivity signal | Torque measurement frequency output Long-term drift due to rated sensitivity | Torque measurement frequency output Rating (nominal) Sensitivity | Torque measurement frequency output Rated (nominal) rotation speed | Torque measurement frequency output rating (nominal) output signal-2 | Torque measurement frequency output rating (nominal) output signal-1 | Torque measurement frequency output Rated (nominal) torque | Torque measurement frequency output Non-linearity including hysteresis3 | Torque measurement frequency output Non-linearity including hysteresis2 | Torque measurement frequency output Nonlinearity including hysteresis1 | Torque measurement frequency output Output signal at torque = 0 | Torque measurement frequency output Effect on zero signal | Shunt Nominal (Rated) Trigger Voltage | Shunt trigger voltage limit | Shunt Shunt signal tolerance | Shunt Shunt signal ON | Shunt Shunt signal OFF |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
T40FM |
Available upon quote |
0.1 (optional 0.05) |
Measurement mode: <1A (typ.0.3: when supply voltage is 20V), startup mode: <4A (typ.2), max. 50μs |
50m |
18~30VDC |
<10W (typ.6) |
When option code 5 is SU2: <400μs, When option code 5 is DU2: <220μs, When option code 5 is HU2: <150μs |
≧2kΩ (with a terminating resistor equivalent to RS-422) |
>2kΩ |
(-3dB) When option code 5 is SU2: 1kHz, When option code 5 is DU2: 3kHz, When option code 5 is HU2: 6kHz |
≤±0.05% (variable) (deviation of output signal according to DIN 1319) |
When option code 5 is SU2: 2.5~17.5kHz, When option code 5 is DU2: 15~105kHz, When option code 5 is HU2: 60~420kHz |
±0.2% (deviation between actual output and rated (nominal) sensitivity in Mnom) |
<±0.05% (temperature effect per 10K when used within the rated temperature range) (ratio to actual torque value) |
≦0.03% (for more than 48 hours at reference temperature) |
When option code 5 is SU2: 5kHz, When option code 5 is DU2: 30kHz, When option code 5 is HU2: 120kHz (Span from zero torque to rated (nominal) torque) |
3,000/4,000/6,000rpm, options: 4,500/6,000/8,000rpm |
At negative rated torque, when option code 5 is SU2: 5kHz, when option code 5 is DU2: 30kHz, when option code 5 is HU2: 120kHz (RS-422, 5V symmetry) |
At positive rated torque, when option code 5 is SU2: 15kHz, when option code 5 is DU2: 90kHz, when option code 5 is HU2: 360kHz (RS-422, 5V symmetry) |
Mnom 15~80kN・m |
From 60% of Mnom to 100% of Mnom: <±0.1 (Optional <±0.05) |
From 20% of Mnom to 60% of Mnom: <±0.065 (option <±0.035) |
From 0% of Mnom to 20% of Mnom: <±0.03 (option <±0.015) |
When option code 5 is SU2: 10kHz, When option code 5 is DU2: 60kHz, When option code 5 is HU2: 240kHz |
<±0.05% (temperature effect per 10K when used within the rated temperature range) (ratio to rated sensitivity) |
5V |
36V |
<±0.05% (ratio to rated torque at reference temperature) |
>2.5V |
<0.7V |