■ Characteristics

The built -in micro -pressure sensor is based on proprietary technology to reduce output offset and common mode errors. This model is proportional to 4V output and has a better output offset feature. Output offset errors due to changes in temperature, warm -up, long -term stability, and posture characteristics are all significantly reduced compared to conventional correction methods. This sensor is effectively used to provide the ideal straight output during pressure measurement due to fine -tuned silicon and structure in which pressure concentration is enhanced. These comparative and temperature corrected sensors provide accurate and stable output in a wide range of temperature changes. This series is intended to be used for non -corrosive and inert gas such as air and dry gas. The output is proportional to the power supply. It is designed to be driven by 4.5 to 5.5 Bolt DC. Medical equipment such as respiratory organs, industrial control, HVAC, environmental control, portable medical terminal, etc. * There are other model numbers.

  • Product

    Output AMP Built -in type Amplifier Ultra low pressure pressure sensor ADCA series

Share this product


650+ people viewing

Last viewed: 23 hours ago


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

10 Models of Output AMP Built -in type Amplifier Ultra low pressure pressure sensor ADCA series

Click on the part number for more information about each product

Image Part Number Price (excluding tax) Measuring category Pressure range Measurement accuracy output Pressure range / INH2O Pressure range / PA Overload pressure / inh2O Overload resistance / KPA Destruction pressure / INH2O Destruction pressure / KPA Rated span Supply voltage (vs) Common mode pressure Read wire durable temperature solder time (2 to 4 seconds) Compensation temperature range Save temperature range Maximum humidity
Output AMP Built -in type Amplifier Ultra low pressure pressure sensor ADCA series-Part Number-0.25 INCH-D-4V

0.25 INCH-D-4V

Available upon quote

Gauge pressure, differential pressure

± 65pa ~ ± 7.5pa, 0-65Pa ... 15kpa

± 0.05 % FSS (maximum ± 0.25 % FSS)

Proportional to 4V output

± 0.25

65

40

Ten

80

20

4V

+4.5 to +5.5VDC

-10 to +10 PSIG

270 ° C

Normal: 5 ~ 50 ° C
Industrial: -25 ~ 85 ° C
Military: -40 ~ 125 ° C

-40 ~ 125 ° C

0 ~ 95% RH

Output AMP Built -in type Amplifier Ultra low pressure pressure sensor ADCA series-Part Number-0.25 INCH-G-4V

0.25 INCH-G-4V

Available upon quote

Gauge pressure, differential pressure

± 65pa ~ ± 7.5pa, 0-65Pa ... 15kpa

± 0.05 % FSS (maximum ± 0.25 % FSS)

Proportional to 4V output

0 to 0.25

65

40

Ten

80

20

4V

+4.5 to +5.5VDC

-10 to +10 PSIG

270 ° C

Normal: 5 ~ 50 ° C
Industrial: -25 ~ 85 ° C
Military: -40 ~ 125 ° C

-40 ~ 125 ° C

0 ~ 95% RH

Output AMP Built -in type Amplifier Ultra low pressure pressure sensor ADCA series-Part Number-0.5 INCH-D-4V

0.5 INCH-D-4V

Available upon quote

Gauge pressure, differential pressure

± 65pa ~ ± 7.5pa, 0-65Pa ... 15kpa

± 0.05 % FSS (maximum ± 0.25 % FSS)

Proportional to 4V output

± 0.5

125

40

Ten

80

20

4V

+4.5 to +5.5VDC

-10 to +10 PSIG

270 ° C

Normal: 5 ~ 50 ° C
Industrial: -25 ~ 85 ° C
Military: -40 ~ 125 ° C

-40 ~ 125 ° C

0 ~ 95% RH

Output AMP Built -in type Amplifier Ultra low pressure pressure sensor ADCA series-Part Number-0.5 INCH-G-4V

0.5 INCH-G-4V

Available upon quote

Gauge pressure, differential pressure

± 65pa ~ ± 7.5pa, 0-65Pa ... 15kpa

± 0.05 % FSS (maximum ± 0.25 % FSS)

Proportional to 4V output

0 to 0.5

125

40

Ten

80

20

4V

+4.5 to +5.5VDC

-10 to +10 PSIG

270 ° C

Normal: 5 ~ 50 ° C
Industrial: -25 ~ 85 ° C
Military: -40 ~ 125 ° C

-40 ~ 125 ° C

0 ~ 95% RH

Output AMP Built -in type Amplifier Ultra low pressure pressure sensor ADCA series-Part Number-1 MBAR-D-4V

1 MBAR-D-4V

Available upon quote

Gauge pressure, differential pressure

± 65pa ~ ± 7.5pa, 0-65Pa ... 15kpa

± 0.05 % FSS (maximum ± 0.25 % FSS)

Proportional to 4V output

± 1 MBAR

100

100

twenty five

200

50

4V

+4.5 to +5.5VDC

-10 to +10 PSIG

270 ° C

Normal: 5 ~ 50 ° C
Industrial: -25 ~ 85 ° C
Military: -40 ~ 125 ° C

-40 ~ 125 ° C

0 ~ 95% RH

Output AMP Built -in type Amplifier Ultra low pressure pressure sensor ADCA series-Part Number-1 INCH-D-4V

1 INCH-D-4V

Available upon quote

Gauge pressure, differential pressure

± 65pa ~ ± 7.5pa, 0-65Pa ... 15kpa

± 0.05 % FSS (maximum ± 0.25 % FSS)

Proportional to 4V output

± 1

250

100

twenty five

200

50

4V

+4.5 to +5.5VDC

-10 to +10 PSIG

270 ° C

Normal: 5 ~ 50 ° C
Industrial: -25 ~ 85 ° C
Military: -40 ~ 125 ° C

-40 ~ 125 ° C

0 ~ 95% RH

Output AMP Built -in type Amplifier Ultra low pressure pressure sensor ADCA series-Part Number-1 INCH-G-4V

1 INCH-G-4V

Available upon quote

Gauge pressure, differential pressure

± 65pa ~ ± 7.5pa, 0-65Pa ... 15kpa

± 0.05 % FSS (maximum ± 0.25 % FSS)

Proportional to 4V output

0 to 1

250

100

twenty five

200

50

4V

+4.5 to +5.5VDC

-10 to +10 PSIG

270 ° C

Normal: 5 ~ 50 ° C
Industrial: -25 ~ 85 ° C
Military: -40 ~ 125 ° C

-40 ~ 125 ° C

0 ~ 95% RH

Output AMP Built -in type Amplifier Ultra low pressure pressure sensor ADCA series-Part Number-2.5 INCH-D-4V

2.5 INCH-D-4V

Available upon quote

Gauge pressure, differential pressure

± 65pa ~ ± 7.5pa, 0-65Pa ... 15kpa

± 0.05 % FSS (maximum ± 0.25 % FSS)

Proportional to 4V output

± 2.5

625

200

50

300

75

4V

+4.5 to +5.5VDC

-10 to +10 PSIG

270 ° C

Normal: 5 ~ 50 ° C
Industrial: -25 ~ 85 ° C
Military: -40 ~ 125 ° C

-40 ~ 125 ° C

0 ~ 95% RH

Output AMP Built -in type Amplifier Ultra low pressure pressure sensor ADCA series-Part Number-2.5 INCH-G-4V

2.5 INCH-G-4V

Available upon quote

Gauge pressure, differential pressure

± 65pa ~ ± 7.5pa, 0-65Pa ... 15kpa

± 0.05 % FSS (maximum ± 0.25 % FSS)

Proportional to 4V output

0 to 2.5

625

200

50

300

75

4V

+4.5 to +5.5VDC

-10 to +10 PSIG

270 ° C

Normal: 5 ~ 50 ° C
Industrial: -25 ~ 85 ° C
Military: -40 ~ 125 ° C

-40 ~ 125 ° C

0 ~ 95% RH

Output AMP Built -in type Amplifier Ultra low pressure pressure sensor ADCA series-Part Number-5 INCH-D-4V

5 INCH-D-4V

Available upon quote

Gauge pressure, differential pressure

± 65pa ~ ± 7.5pa, 0-65Pa ... 15kpa

± 0.05 % FSS (maximum ± 0.25 % FSS)

Proportional to 4V output

± 5

1,250

200

50

300

75

4V

+4.5 to +5.5VDC

-10 to +10 PSIG

270 ° C

Normal: 5 ~ 50 ° C
Industrial: -25 ~ 85 ° C
Military: -40 ~ 125 ° C

-40 ~ 125 ° C

0 ~ 95% RH

Click on the part number for more information about each product

Customers who viewed this product also viewed

Reviews shown here are reviews of companies.

See More Pressure Sensors Products

Other products of Krone Co., Ltd.

Reviews shown here are reviews of companies.


View more products of Krone Co., Ltd.

About Company Handling This Product

Response Rate

100.0%


Response Time

9.0hrs


Company Review

4.5
  • Japan

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree