High -precision digital micro -pressure meter/drip -proof dustproof BOX KS2900-KS2900
High -precision digital micro -pressure meter/drip -proof dustproof BOX KS2900-KS2900 in The Box (brass)
High -precision digital micro -pressure meter/drip -proof dustproof BOX KS2900-KS2900 Multi-BOX
High -precision digital micro -pressure meter/drip -proof dustproof BOX KS2900-Krone Co., Ltd.

High -precision digital micro -pressure meter/drip -proof dustproof BOX KS2900
Krone Co., Ltd.


About This Product

■ Overview ・ The digital micro -pressure monitor KS2900 is a model that uses a high control LCD for the display part so that the visibility is higher while keeping the function, accuracy and price of the KS2700, which has many years of track record. -The KS2900 is a novel panel based on black that emphasizes design, and the installation has been designed so that it can be easily performed with one touch from the front. ・ The range is 0-100 PA to 2,500 PA (differential pressure), ± 100 PA to ± 2,500 PA (compilation pressure), and analog output can be selected from 2 types, 4-20mA or 1-5V. ・ Various settings can be easily made with the key on the front of the panel. The KS2900, which has been developed and developed so that almost all functions can be measured and controlled by this one unit, can be used for a wide range of applications, from semiconductor manufacturing devices to air conditioning monitoring and control. ■ Product feature ・ Short warming up time ・ Construction of fleet function ・ Energy saving by adopting LCD display ・ With analog signal output ・ High contrast LCD adoption ・ Hysteresis and comparative delay settings can be set ・ Display rate time can be set ・ HI / GO / LO comparison setting Output is possible Overview of the main setting function ■ Comparison (alarm) setting Set the value of Hi and LO. You can also set the direction of HI and LO, hysteresis, output logic, comparative value delay, comparative output ON/OFF, etc. ■ Hysteresis When the actual pressure approaches or separates to the set HI or LO value, chattering may be caused. You can prevent this phenomenon by setting this value. ■ Comparative price delay ・ If the actual pressure reaches the set HI or LO value instantaneously, it may be troublesome to operate immediately. ・ You can delay the operation by setting this value. (See the right output mode example) ■ Forced zero By pressing the up/zero key on the panel surface, the zero point is forcibly corrected. ■ Sampling rate and display rate By setting the combination of this rate, the average value is displayed. Since the sampling rate is 0.1Sec, for example, if the display rate is set to 0.5sec, the average value of five measurements will be displayed as a result. Various applications are possible. ■ Moving average The moving average of this setting is displayed only. It can be applied to intense pressure measurement and control of pulsation. (Can be set from 1 to 255 times) ■ Others There is a setting function such as LOW cut rate, zero sapress, minimum digit fixing. Please ask for details.

  • Product

    High -precision digital micro -pressure meter/drip -proof dustproof BOX KS2900




*Please note that we may not be able to accommodate sample requests.

4 Models of High -precision digital micro -pressure meter/drip -proof dustproof BOX KS2900

Items marked with have different values ​​depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Analog output Bearing pressure Case material Comparison setting output Display accuracy Electrical connection Fitting material Input power supply voltage Measurement medium Measurement method Mounting posture Operating temperature limit Pressure port Pressure range (PA) Protection grade Save temperature range Standards / authentication Temperature characteristics Used humidity range Warming up accuracy display mass power consumption
High -precision digital micro -pressure meter/drip -proof dustproof BOX KS2900-Part Number-KS2900

KS2900

Available upon quote 4-20ma / 1-5V (optional) Deferment: 0-2,500 / 7.5 kpa
Deferment: 0-1,000 0-500 0-300 0-100 / 5.0 kpa
Compilation pressure: 0- ± 2,500 / 7.5 kpa
Compilation pressure: 0- ± 1,000 0- ± 500 0- ± 300 0- ± 100 / 5.0 kpa
- HI / LO / GO 3 point output
Setting method: push -type digital settings
Setting range: 0-100% F.S.
Output format: NPN Open Collector, HI / LO / GO 3 points Independent output / PNP (optional)
Maximum load current: 100mA (vol = 1.35V) * resistance load
Maximum applied voltage: 35V or less
Accuracy ± 1digit 8 PIN connector - DC12V or DC24V (± 10%) Air and non -corrosive gases (no dust) Semiconductor differential pressure method Panel mounting (cut dimensions: 45.0W x 22.2h) 0 ℃ ~ 50 ° C (no freezing) Outer diameter: Entrance φ2.1mm maximum φ3.5mm conical type Deferment: 0-2500 0-1000 0-500 0-300 0-100
Compilation pressure: 0- ± 2500 0- ± 1000 0- ± 500 0- ± 300- ± 100
IP40 (indoor specification) -20 ℃ ~ 70 ℃ CE, UL, Rohs Difference: 0-2,500 0-1,000 0-500 0-300 / ± 0.1% F.S. / ℃ or less
Difference: 0-100 / ± 0.15% F.S. / ℃ or less
Compilation pressure: 0- ± 2,500 0- ± 1,000 0- ± 500 0- ± 300 / ± 0.1% F.S. / ℃ or less
Compilation pressure: 0- ± 100 / ± 0.15% F.S. / ℃ or less
35 % to 85 % (not condensation) 5 minutes Difference: 0-2,500 0-1,000 0-500 / ± 1.0% F.S.
Difference: 0-300 / ± 1.5% F.S.
Difference: 0-100 / ± 3.0% F.S.
Compilation pressure: 0- ± 2,500 0- ± 1,000 0- ± 500 / ± 1.0% F.S.
Compilation pressure: 0- ± 300 / ± 1.5% F.S.
Compilation pressure: 0- ± 100 / ± 3.0% F.S.
Full 4 -digit LCD display
Pressure display: 4 digits LCD (unit: PA)
Comparison display: HI / LO / GO 3 points LCD display
LO cut: There is a non -sensitive band setting function
Forced zero: Push type forced zero function * Regular implementation (recommended)
Approximately 40g 1W (output 20mA, when backlight lighting) * Not included comparator output
High -precision digital micro -pressure meter/drip -proof dustproof BOX KS2900-Part Number-KS2900 in The Box (brass)

KS2900 in The Box (brass)

Available upon quote 4-20ma / 1-5V (optional) Deferment: 0-2,500 / 7.5 kpa
Deferment: 0-1,000 0-500 0-300 0-100 / 5.0 kpa
Compilation pressure: 0- ± 2,500 / 7.5 kpa
Compilation pressure: 0- ± 1,000 0- ± 500 0- ± 300 0- ± 100 / 5.0 kpa
Polycarbonate HI / LO / GO 3 point output
Setting method: push -type digital settings
Setting range: 0-100% F.S.
Output format: NPN Open Collector, HI / LO / GO 3 points Independent output / PNP (optional)
Maximum load current: 100mA (vol = 1.35V) * resistance load
Maximum applied voltage: 35V or less
Accuracy ± 1digit 8 PIN connector Brass DC12V or DC24V (± 10%) Air and non -corrosive gases (no dust) Semiconductor differential pressure method nothing special 0 ℃ ~ 50 ° C (no freezing) Outer diameter: Entrance φ2.1mm maximum φ3.5mm conical type Deferment: 0-2500 0-1000 0-500 0-300 0-100
Compilation pressure: 0- ± 2500 0- ± 1000 0- ± 500 0- ± 300- ± 100
IP65 -20 ℃ ~ 70 ℃ CE Difference: 0-2,500 0-1,000 0-500 0-300 / ± 0.1% F.S. / ℃ or less
Difference: 0-100 / ± 0.15% F.S. / ℃ or less
Compilation pressure: 0- ± 2,500 0- ± 1,000 0- ± 500 0- ± 300 / ± 0.1% F.S. / ℃ or less
Compilation pressure: 0- ± 100 / ± 0.15% F.S. / ℃ or less
85%RH or less (not condensation) 5 minutes Difference: 0-2,500 0-1,000 0-500 / ± 1.0% F.S.
Difference: 0-300 / ± 1.5% F.S.
Difference: 0-100 / ± 3.0% F.S.
Compilation pressure: 0- ± 2,500 0- ± 1,000 0- ± 500 / ± 1.0% F.S.
Compilation pressure: 0- ± 300 / ± 1.5% F.S.
Compilation pressure: 0- ± 100 / ± 3.0% F.S.
Full 4 -digit LCD display
Pressure display: 4 digits LCD (unit: PA)
Comparison display: HI / LO / GO 3 points LCD display
LO cut: There is a non -sensitive band setting function
Forced zero: Push type forced zero function * Regular implementation (recommended)
Approximately 730g 1W (output 20mA, when backlight lighting) * Not included comparator output
High -precision digital micro -pressure meter/drip -proof dustproof BOX KS2900-Part Number-KS2900 in The Box (SUS)

KS2900 in The Box (SUS)

Available upon quote 4-20ma / 1-5V (optional) Deferment: 0-2,500 / 7.5 kpa
Deferment: 0-1,000 0-500 0-300 0-100 / 5.0 kpa
Compilation pressure: 0- ± 2,500 / 7.5 kpa
Compilation pressure: 0- ± 1,000 0- ± 500 0- ± 300 0- ± 100 / 5.0 kpa
Polycarbonate HI / LO / GO 3 point output
Setting method: push -type digital settings
Setting range: 0-100% F.S.
Output format: NPN Open Collector, HI / LO / GO 3 points Independent output / PNP (optional)
Maximum load current: 100mA (vol = 1.35V) * resistance load
Maximum applied voltage: 35V or less
Accuracy ± 1digit 8 PIN connector SUS DC12V or DC24V (± 10%) Air and non -corrosive gases (no dust) Semiconductor differential pressure method nothing special 0 ℃ ~ 50 ° C (no freezing) Outer diameter: Entrance φ2.1mm maximum φ3.5mm conical type Deferment: 0-2500 0-1000 0-500 0-300 0-100
Compilation pressure: 0- ± 2500 0- ± 1000 0- ± 500 0- ± 300- ± 100
IP65 -20 ℃ ~ 70 ℃ CE Difference: 0-2,500 0-1,000 0-500 0-300 / ± 0.1% F.S. / ℃ or less
Difference: 0-100 / ± 0.15% F.S. / ℃ or less
Compilation pressure: 0- ± 2,500 0- ± 1,000 0- ± 500 0- ± 300 / ± 0.1% F.S. / ℃ or less
Compilation pressure: 0- ± 100 / ± 0.15% F.S. / ℃ or less
85%RH or less (not condensation) 5 minutes Difference: 0-2,500 0-1,000 0-500 / ± 1.0% F.S.
Difference: 0-300 / ± 1.5% F.S.
Difference: 0-100 / ± 3.0% F.S.
Compilation pressure: 0- ± 2,500 0- ± 1,000 0- ± 500 / ± 1.0% F.S.
Compilation pressure: 0- ± 300 / ± 1.5% F.S.
Compilation pressure: 0- ± 100 / ± 3.0% F.S.
Full 4 -digit LCD display
Pressure display: 4 digits LCD (unit: PA)
Comparison display: HI / LO / GO 3 points LCD display
LO cut: There is a non -sensitive band setting function
Forced zero: Push type forced zero function * Regular implementation (recommended)
Approximately 730g 1W (output 20mA, when backlight lighting) * Not included comparator output
High -precision digital micro -pressure meter/drip -proof dustproof BOX KS2900-Part Number-KS2900 Multi-BOX

KS2900 Multi-BOX

Available upon quote 4-20ma / 1-5V (optional) Deferment: 0-2,500 / 7.5 kpa
Deferment: 0-1,000 0-500 0-300 0-100 / 5.0 kpa
Compilation pressure: 0- ± 2,500 / 7.5 kpa
Compilation pressure: 0- ± 1,000 0- ± 500 0- ± 300 0- ± 100 / 5.0 kpa
- HI / LO / GO 3 point output
Setting method: push -type digital settings
Setting range: 0-100% F.S.
Output format: NPN Open Collector, HI / LO / GO 3 points Independent output / PNP (optional)
Maximum load current: 100mA (vol = 1.35V) * resistance load
Maximum applied voltage: 35V or less
Accuracy ± 1digit 6 PIN Euro block connector - - Air and non -corrosive gases (no dust) Semiconductor differential pressure method Panel mounting (cut dimensions: 45.0W x 22.2h) 0 ℃ ~ 50 ° C (no freezing) Outer diameter: Entrance φ2.1mm maximum φ3.5mm conical type Deferment: 0-2500 0-1000 0-500 0-300 0-100
Compilation pressure: 0- ± 2500 0- ± 1000 0- ± 500 0- ± 300- ± 100
IP40 (indoor specification) -20 ℃ ~ 70 ℃ CE, UL, Rohs Difference: 0-2,500 0-1,000 0-500 0-300 / ± 0.1% F.S. / ℃ or less
Difference: 0-100 / ± 0.15% F.S. / ℃ or less
Compilation pressure: 0- ± 2,500 0- ± 1,000 0- ± 500 0- ± 300 / ± 0.1% F.S. / ℃ or less
Compilation pressure: 0- ± 100 / ± 0.15% F.S. / ℃ or less
35 % to 85 % (not condensation) 5 minutes Difference: 0-2,500 0-1,000 0-500 / ± 1.0% F.S.
Difference: 0-300 / ± 1.5% F.S.
Difference: 0-100 / ± 3.0% F.S.
Compilation pressure: 0- ± 2,500 0- ± 1,000 0- ± 500 / ± 1.0% F.S.
Compilation pressure: 0- ± 300 / ± 1.5% F.S.
Compilation pressure: 0- ± 100 / ± 3.0% F.S.
Full 4 -digit LCD display
Pressure display: 4 digits LCD (unit: PA)
Comparison display: HI / LO / GO 3 points LCD display
LO cut: There is a non -sensitive band setting function
Forced zero: Push type forced zero function * Regular implementation (recommended)
Approximately 2.1kg 10W * Not included comparator output

Click on the part number for more information about each product

Customers who viewed this product also viewed

Other products of Krone Co., Ltd.


View more products of Krone Co., Ltd.

About Company Handling This Product

Krone Co., Ltd.

  • Japan
  • Since 1980

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree