Remote monitoring system IDC-SVS4 measurement module that is optimal if you want to concentrate on the operating status of the distribution board remotely-IDC-SVS4-MDL-ACWH
Remote monitoring system IDC-SVS4 measurement module that is optimal if you want to concentrate on the operating status of the distribution board remotely-Hexacore Co., Ltd.

Remote monitoring system IDC-SVS4 measurement module that is optimal if you want to concentrate on the operating status of the distribution board remotely
Hexacore Co., Ltd.


About This Product

■ Costs can be reduced by initial installation

Since we are consistently performed from design to inspection, we can reduce the cost in total by initially installing measurement modules and sensors. Before shipping, the sensor mounted position and load inspection are also performed, so there is no need for a load test on site. If you use CEW-M4 for the surveillance server, automatically create and register a master for additional installation based on the module allocation material mounted on the board. You can prevent sensor setting mistakes and compress the number of boards.

■ You can build a system in combination with various sensors

We support all requests in data centers and communication buildings. Single -phase 2 -line power, three -phase 3 -line power capacity, single -phase three -line capacity, AC current (60A, 100A, 200A, 200A, 400A, 600A), DC current (50A, 100A, 250A, 500A), temperature, humidity Various measurement modules and sensors are available.

■ In the unlikely event, the measurement value can be prevented.

The relay device is stored in 2 days (for RACK EYE) or in the internal memory for 7 days (for CEW-M4 server). You can send the measured value. In order to prevent the loss of measured values, many business companies that provide measured values ​​data are adopted for end users.

■ Functional

By measuring using each sensor and measuring the measurement module, it is possible to measure the single -phase two -line power, three -phase three -line, three -phase, three -phase 3 -line capacity, a single -phase of 3 -phase 3 -line, exchange current, DC current, temperature, temperature, and humidity. Possible. Up to four current sensors can be connected for each measurement module. Up to 32 /16 units can be connected to temperature / temperature and humidity sensors per measurement module.

  • Product

    Remote monitoring system IDC-SVS4 measurement module that is optimal if you want to concentrate on the operating status of the distribution board remotely

Share this product


260+ people viewing

Last viewed: 19 hours ago


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

6 Models of Remote monitoring system IDC-SVS4 measurement module that is optimal if you want to concentrate on the operating status of the distribution board remotely

Click on the part number for more information about each product

Image Part Number Price (excluding tax) accuracy
Remote monitoring system IDC-SVS4 measurement module that is optimal if you want to concentrate on the operating status of the distribution board remotely-Part Number-IDC-SVS4-MDL-ACWH

IDC-SVS4-MDL-ACWH

Available upon quote

Exchange current: ± 1.5%F.S (not included)
AC voltage: ± 2.0%F.S (not included)
Effective integrated power: ± 3.0% (not included)
DC current: ± 3.0%F.S

Remote monitoring system IDC-SVS4 measurement module that is optimal if you want to concentrate on the operating status of the distribution board remotely-Part Number-IDC-SVS4-MDL-AC3WH

IDC-SVS4-MDL-AC3WH

Available upon quote

Exchange current: ± 1.5%F.S (not included)
AC voltage: ± 2.0%F.S (not included)
Effective integrated power: ± 3.0% (not included)
DC current: ± 3.0%F.S

Remote monitoring system IDC-SVS4 measurement module that is optimal if you want to concentrate on the operating status of the distribution board remotely-Part Number-IDC-SVS4-MDL-AC1P3WH

IDC-SVS4-MDL-AC1P3WH

Available upon quote

Exchange current: ± 1.5%F.S (not included)
AC voltage: ± 2.0%F.S (not included)
Effective integrated power: ± 3.0% (not included)
DC current: ± 3.0%F.S

Remote monitoring system IDC-SVS4 measurement module that is optimal if you want to concentrate on the operating status of the distribution board remotely-Part Number-IDC-SVS4-MDL-AC

IDC-SVS4-MDL-AC

Available upon quote

Exchange current: ± 1.5%F.S (not included)
AC voltage: ± 2.0%F.S (not included)
Effective integrated power: ± 3.0% (not included)
DC current: ± 3.0%F.S

Remote monitoring system IDC-SVS4 measurement module that is optimal if you want to concentrate on the operating status of the distribution board remotely-Part Number-IDC-SVS4-MDL-DC

IDC-SVS4-MDL-DC

Available upon quote

Exchange current: ± 1.5%F.S (not included)
AC voltage: ± 2.0%F.S (not included)
Effective integrated power: ± 3.0% (not included)
DC current: ± 3.0%F.S

Remote monitoring system IDC-SVS4 measurement module that is optimal if you want to concentrate on the operating status of the distribution board remotely-Part Number-IDC-SVS4-MDL-O1

IDC-SVS4-MDL-O1

Available upon quote

Exchange current: ± 1.5%F.S (not included)
AC voltage: ± 2.0%F.S (not included)
Effective integrated power: ± 3.0% (not included)
DC current: ± 3.0%F.S

Click on the part number for more information about each product