Remote monitoring system IDC-SVS4 measurement module that is optimal if you want to concentrate on the operating status of the distribution board remotely-IDC-SVS4-MDL-ACWH
Remote monitoring system IDC-SVS4 measurement module that is optimal if you want to concentrate on the operating status of the distribution board remotely-Hexacore Co., Ltd.

Remote monitoring system IDC-SVS4 measurement module that is optimal if you want to concentrate on the operating status of the distribution board remotely
Hexacore Co., Ltd.


About This Product

■ Costs can be reduced by initial installation Since we are consistently performed from design to inspection, we can reduce the cost in total by initially installing measurement modules and sensors. Before shipping, the sensor mounted position and load inspection are also performed, so there is no need for a load test on site. If you use CEW-M4 for the surveillance server, automatically create and register a master for additional installation based on the module allocation material mounted on the board. You can prevent sensor setting mistakes and compress the number of boards. ■ You can build a system in combination with various sensors We support all requests in data centers and communication buildings. Single -phase 2 -line power, three -phase 3 -line power capacity, single -phase three -line capacity, AC current (60A, 100A, 200A, 200A, 400A, 600A), DC current (50A, 100A, 250A, 500A), temperature, humidity Various measurement modules and sensors are available. ■ In the unlikely event, the measurement value can be prevented. The relay device is stored in 2 days (for RACK EYE) or in the internal memory for 7 days (for CEW-M4 server). You can send the measured value. In order to prevent the loss of measured values, many business companies that provide measured values ​​data are adopted for end users. ■ Functional By measuring using each sensor and measuring the measurement module, it is possible to measure the single -phase two -line power, three -phase three -line, three -phase, three -phase 3 -line capacity, a single -phase of 3 -phase 3 -line, exchange current, DC current, temperature, temperature, and humidity. Possible. Up to four current sensors can be connected for each measurement module. Up to 32 /16 units can be connected to temperature / temperature and humidity sensors per measurement module.

  • Product

    Remote monitoring system IDC-SVS4 measurement module that is optimal if you want to concentrate on the operating status of the distribution board remotely




*Please note that we may not be able to accommodate sample requests.

6 Models of Remote monitoring system IDC-SVS4 measurement module that is optimal if you want to concentrate on the operating status of the distribution board remotely

Items marked with have different values ​​depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) accuracy
Remote monitoring system IDC-SVS4 measurement module that is optimal if you want to concentrate on the operating status of the distribution board remotely-Part Number-IDC-SVS4-MDL-ACWH

IDC-SVS4-MDL-ACWH

Available upon quote Exchange current: ± 1.5%F.S (not included)
AC voltage: ± 2.0%F.S (not included)
Effective integrated power: ± 3.0% (not included)
DC current: ± 3.0%F.S
Remote monitoring system IDC-SVS4 measurement module that is optimal if you want to concentrate on the operating status of the distribution board remotely-Part Number-IDC-SVS4-MDL-AC3WH

IDC-SVS4-MDL-AC3WH

Available upon quote Exchange current: ± 1.5%F.S (not included)
AC voltage: ± 2.0%F.S (not included)
Effective integrated power: ± 3.0% (not included)
DC current: ± 3.0%F.S
Remote monitoring system IDC-SVS4 measurement module that is optimal if you want to concentrate on the operating status of the distribution board remotely-Part Number-IDC-SVS4-MDL-AC1P3WH

IDC-SVS4-MDL-AC1P3WH

Available upon quote Exchange current: ± 1.5%F.S (not included)
AC voltage: ± 2.0%F.S (not included)
Effective integrated power: ± 3.0% (not included)
DC current: ± 3.0%F.S
Remote monitoring system IDC-SVS4 measurement module that is optimal if you want to concentrate on the operating status of the distribution board remotely-Part Number-IDC-SVS4-MDL-AC

IDC-SVS4-MDL-AC

Available upon quote Exchange current: ± 1.5%F.S (not included)
AC voltage: ± 2.0%F.S (not included)
Effective integrated power: ± 3.0% (not included)
DC current: ± 3.0%F.S
Remote monitoring system IDC-SVS4 measurement module that is optimal if you want to concentrate on the operating status of the distribution board remotely-Part Number-IDC-SVS4-MDL-DC

IDC-SVS4-MDL-DC

Available upon quote Exchange current: ± 1.5%F.S (not included)
AC voltage: ± 2.0%F.S (not included)
Effective integrated power: ± 3.0% (not included)
DC current: ± 3.0%F.S
Remote monitoring system IDC-SVS4 measurement module that is optimal if you want to concentrate on the operating status of the distribution board remotely-Part Number-IDC-SVS4-MDL-O1

IDC-SVS4-MDL-O1

Available upon quote Exchange current: ± 1.5%F.S (not included)
AC voltage: ± 2.0%F.S (not included)
Effective integrated power: ± 3.0% (not included)
DC current: ± 3.0%F.S

Click on the part number for more information about each product

Other products of Hexacore Co., Ltd.


View more products of Hexacore Co., Ltd.

About Company Handling This Product

Hexacore Co., Ltd.

  • Japan
  • Since 1943
  • 143 employees

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree