Exchange distribution board for data centers, which distributes power provided by UPS to lower devices such as PDP, PDU-Series-PDU-Series
Exchange distribution board for data centers, which distributes power provided by UPS to lower devices such as PDP, PDU-Series-Hexacore Co., Ltd.

Exchange distribution board for data centers, which distributes power provided by UPS to lower devices such as PDP, PDU-Series
Hexacore Co., Ltd.


About This Product

■ We can handle a wide range of requests, such as installing various transformers and measuring instruments. Various transformers have been installed, from small capacity to large capacity of 600 kva. Including 3 -phase and 3 lines, 3 -phase 4 lines, 3 -phase 7 lines, scott transformer, etc. can be flexible. We will accept specifications that are not listed in the catalog, so please feel free to contact us. ■ For measuring instruments, you can equip Pal-Plus and SVS4, which are our own developments, can be installed. Current measurement and remote monitoring function achieve safe equipment construction. The measuring instruments can be shipped in a state of mounted on the board, and can save labor on local work. ■ Contribute to the construction of a safe data center by harmonics measures The power supply built into the server causes a high -conditioning waveform in the interaction/DC conversion process, which may cause the temperature rise of the conductive portion. Therefore, as a measure against harmonics, we support K-FACTOR transformers and increase the size of electric wires. By designing products in consideration of harmonics, we contribute to the operation of a safe data center. ■ Many products delivered to data centers, including major companies Our products have been introduced at many facilities, regardless of size and industry. Based on the know -how obtained from the delivery results of many products to the data center, we will provide the best products to our customers. We carry out regular inspections and aftercare even after the product is delivered, and support it for a long time.

  • Product

    Exchange distribution board for data centers, which distributes power provided by UPS to lower devices such as PDP, PDU-Series




*Please note that we may not be able to accommodate sample requests.

1 Models of Exchange distribution board for data centers, which distributes power provided by UPS to lower devices such as PDP, PDU-Series

Product Image Part Number Price (excluding tax) Electrical leakage relay Neutrality reinforcement SPD Transformer input measurement output
Exchange distribution board for data centers, which distributes power provided by UPS to lower devices such as PDP, PDU-Series-Part Number-PDU-Series

PDU-Series

Available upon quote presence or absence 200 %, none presence or absence Capacity / 100kva ~ 600kva
Exciting magnetate current ratio / wavy high value 1x, wavy height is 2 times or less, wavy high value 8 times or less
K-FACTOR / 4, 13, None
Accessories / flat wheels, anti -vibration rubber, dial thermometer
3φ3W200V class
3φ3W400V class
Transformer primary / WHM, mm, PQM, none
Transformer secondary / WHM, mm, PQM, none
Sending circuit / WHM, MM, Pal-Plus, SVS4, no
Rated (acceptable adjustment) / 50AF ~ 2000AF
Output terminal configuration / cable compatible, bath duct support

Customers who viewed this product also viewed

Other products of Hexacore Co., Ltd.


View more products of Hexacore Co., Ltd.

About Company Handling This Product

Hexacore Co., Ltd.

  • Japan
  • Since 1943
  • 143 employees

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree