A board -mounted MCCB current display that can be measured and saved that can check the exchange current in the distribution board with a panel display.Handling Company
Hexacore Co., Ltd.Items marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | Applied cable diameter | Failure alarm function (master) | Indicator display | Maximum measurement point | Measured data accumulation (master) | Measurement range | No load threshold (low cut) | Power-supply voltage | Pre -alarm function (master) | Screen size | Supply ability | accuracy | panel |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
MVS-MDL16-M60-Pal |
Available upon quote | Exchange current 60A: ~ 14mm2 (~ φ10.0) |
Warning output at the contact when power is disconnected when the master itself is turned off Failure alarm alarm contact: AC250V / 100mA (B contact) |
Display the operation status in LED POW (green): Power supply Act (orange): Operation Link (green): Communication ALM (orange): Equipment alarm |
64 points |
Measured data can be stored inside the master body. Can be taken out using USB memory Storage capacity: 13 months (64 points 1 minute cycle) |
AC0.0A ~ 60.0A | 410ma | - |
Set the upper limit and lower limit and output alarm outside. Warning reset can be selected from automatic or manual reset Pre -alarm warning point: AC250V / 100mA (A contact) |
- | - | ± 3%F.S. | - | |
MVS-MDL16-S60 |
Available upon quote | Exchange current 60A: ~ 14mm2 (~ φ10.0) |
Warning output at the contact when power is disconnected when the master itself is turned off Failure alarm alarm contact: AC250V / 100mA (B contact) |
Display the operation status in LED POW (green): Power supply Act (orange): Operation Link (green): Communication ALM (orange): Equipment alarm |
64 points |
Measured data can be stored inside the master body. Can be taken out using USB memory Storage capacity: 13 months (64 points 1 minute cycle) |
AC0.0A ~ 60.0A | 410ma | - |
Set the upper limit and lower limit and output alarm outside. Warning reset can be selected from automatic or manual reset Pre -alarm warning point: AC250V / 100mA (A contact) |
- | - | ± 3%F.S. | - | |
MVS-POW-A (power supply unit) |
Available upon quote | - | - | - | - | - | - | - | AC100V ~ AC240V 50 / 60Hz | - | - | DC ± 12V / 3.8a (45W) | - | - | |
MVS-DISP (panel display) |
Available upon quote | - | - | - | - | - | - | - | - | - | Type 3.8 | - | - | Touch panel |